Published in: Clinical Oral Investigations 3/2021

Open Access 01-03-2021 | Original Article

Accuracy of fully guided orthodontic mini-implant placement evaluated by cone-beam computed tomography: a study involving human cadaver heads

Authors: Kristian Kniha, Maximilian Brandt, Anna Bock, Ali Modabber, Andreas Prescher, Frank Hölzle, Golamreza Danesh, Stephan Christian Möhlhenrich

Published in: Clinical Oral Investigations | Issue 3/2021

Login to get access

Abstract

Objectives

The aim of this study was to evaluate the accuracy of fully guided orthodontic mini-implant (OMI) placements supported by tooth- (TBGs) or gingiva-borne silicone guides (GBGs) based on virtually superimposed lateral cephalograms on virtual plaster models.

Materials and methods

Lateral cephalograms and corresponding plaster models were virtually superimposed for the planning of OMI positions; fully guided TBGs and GBGs were fabricated (each, n = 10). A total of 40 OMIs were inserted in a paramedian position into the palate of 20 human cadavers. Postoperative cone-beam computer tomographies (CBCTs) were carried out, and an accuracy evaluation was performed by comparing preoperative planning models and postoperative CBCTs. Deviations of the axis, tip, centre of the shoulder and vertical position of each of the implants were evaluated. Furthermore, the transfer accuracy measured by postoperative CBCT scans were compared with the accuracy determined using an intraoral scanner.

Results

A significant deviation between TBGs (2.81° SD 2.69) and GBGs (6.22° SD 4.26) regarding implant angulation was evaluated (p = 0.005). Implant tip and implant shoulder deviations revealed no statistical differences between the guides. Accuracy values of oral scans regarding vertical deviations were significantly more inaccurate when compared with CBCTs (p < 0.001).

Conclusions

The accuracy of an OMI position can be significantly increased by using a guide extension over the teeth. Vertical implant positions presented the lowest deviations. Postoperative oral scans and CBCTs represent diverging accuracy measurements when compared with virtual planning.

Clinical relevance

Users must keep in mind that despite virtual planning deviations, inaccuracies of a few millimetres may occur.
Literature
2.
go back to reference Kanomi R (1997) Mini-implant for orthodontic anchorage. J Clin Orthod 31:763–767PubMed Kanomi R (1997) Mini-implant for orthodontic anchorage. J Clin Orthod 31:763–767PubMed
3.
go back to reference Freudenthaler JW, Haas R, Bantleon HP (2001) Bicortical titanium screws for critical orthodontic anchorage in the mandible: a preliminary report on clinical applications. Clin Oral Implants Res 12:358–363CrossRef Freudenthaler JW, Haas R, Bantleon HP (2001) Bicortical titanium screws for critical orthodontic anchorage in the mandible: a preliminary report on clinical applications. Clin Oral Implants Res 12:358–363CrossRef
5.
go back to reference Melsen B, Costa A (2000) Immediate loading of implants used for orthodontic anchorage. Clin Orthod Res 3:23–28CrossRef Melsen B, Costa A (2000) Immediate loading of implants used for orthodontic anchorage. Clin Orthod Res 3:23–28CrossRef
6.
go back to reference Ludwig B, Glasl B, Bowman SJ, Wilmes B, Kinzinger GS, Lisson JA (2011) Anatomical guidelines for miniscrew insertion: palatal sites. J Clin Orthod 45:433–441 quiz 467PubMed Ludwig B, Glasl B, Bowman SJ, Wilmes B, Kinzinger GS, Lisson JA (2011) Anatomical guidelines for miniscrew insertion: palatal sites. J Clin Orthod 45:433–441 quiz 467PubMed
8.
9.
go back to reference Wehrbein H, Merz BR, Diedrich P, Glatzmaier J (1996) The use of palatal implants for orthodontic anchorage. Design and clinical application of the orthosystem. Clin Oral Implants Res 7:410–416CrossRef Wehrbein H, Merz BR, Diedrich P, Glatzmaier J (1996) The use of palatal implants for orthodontic anchorage. Design and clinical application of the orthosystem. Clin Oral Implants Res 7:410–416CrossRef
22.
go back to reference Rutkunas V, Geciauskaite A, Jegelevicius D, Vaitiekunas M (2017) Accuracy of digital implant impressions with intraoral scanners. A systematic review. Eur J Oral Implantol 10(Suppl 1):101–120PubMed Rutkunas V, Geciauskaite A, Jegelevicius D, Vaitiekunas M (2017) Accuracy of digital implant impressions with intraoral scanners. A systematic review. Eur J Oral Implantol 10(Suppl 1):101–120PubMed
25.
26.
go back to reference Jung RE, Schneider D, Ganeles J, Wismeijer D, Zwahlen M, Hammerle CH, Tahmaseb A (2009) Computer technology applications in surgical implant dentistry: a systematic review. Int J Oral Maxillofac Implants 24(Suppl):92–109PubMed Jung RE, Schneider D, Ganeles J, Wismeijer D, Zwahlen M, Hammerle CH, Tahmaseb A (2009) Computer technology applications in surgical implant dentistry: a systematic review. Int J Oral Maxillofac Implants 24(Suppl):92–109PubMed
28.
Metadata
Title
Accuracy of fully guided orthodontic mini-implant placement evaluated by cone-beam computed tomography: a study involving human cadaver heads
Authors
Kristian Kniha
Maximilian Brandt
Anna Bock
Ali Modabber
Andreas Prescher
Frank Hölzle
Golamreza Danesh
Stephan Christian Möhlhenrich
Publication date
01-03-2021
Publisher
Springer Berlin Heidelberg
Published in
Clinical Oral Investigations / Issue 3/2021
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-020-03436-9

Other articles of this Issue 3/2021

Clinical Oral Investigations 3/2021 Go to the issue