Abstract

Purpose

The technique of pedicle screw stabilization is finding increasing popularity for use in the cervical spine. Implementing anterior transpedicular screws (ATPS) in cervical spine offers theoretical advantages compared to posterior stabilization. The goal of the current study was the development of a new setting for navigated insertion of ATPS, combining the advantage of reduced invasiveness of an anterior approach with the technical advantages of navigation.

Methods

20 screws were implanted in levels C3 to C6 of four cervical spine models (SAWBONES® Cervical Vertebrae with Anterior Ligament) with the use of 3D fluoroscopy navigation system [Arcadis Orbic 3D, Siemens and VectorVision fluoro 3D trauma software (BrainLAB)]. The accuracy of inserted screws was analyzed according to postoperative CT scans and following the modified Gertzbein and Robbins classification.

Results

20 anterior pedicle screws were placed in four human cervical spine models. Of these, eight screws were placed in C3, two screws in C4, six screws in C5, and four screws in C6. 16 of 20 screws (80 %) reached a grade 1 level of accuracy according to the modified Gertzbein and Robbins Classification. Three screws (15 %) were grade 2, and one screw (5 %) was grade 3. Grade 4 and 5 positions were not evident. Summing grades 1 and 2 together as “good” positions, 95 % of the screws achieved this level. Only a single screw did not fulfill these criteria.

Conclusion

The setting introduced in this study for navigated insertion of ATPS into cervical spine bone models is well implemented and shows excellent results, with an accuracy of 95 % (Gertzbein and Robbins grade 2 or better). Thus, this preliminary study represents a prelude to larger studies with larger case numbers on human specimens.
Literature
1.
4.
go back to reference Xu R, Ebraheim NA, Skie M (2008) Pedicle screw fixation in the cervical spine. Am J Orthop (Belle Mead NJ) 37(8):403–408 (discussion 408) Xu R, Ebraheim NA, Skie M (2008) Pedicle screw fixation in the cervical spine. Am J Orthop (Belle Mead NJ) 37(8):403–408 (discussion 408)
5.
go back to reference Blauth M, Richter M, Lange U (1999) Trans-articular screw fixation of C1/C2 in atlanto-axial instability. Comparison between percutaneous and open procedures. Orthopade 28(8):651–661PubMed Blauth M, Richter M, Lange U (1999) Trans-articular screw fixation of C1/C2 in atlanto-axial instability. Comparison between percutaneous and open procedures. Orthopade 28(8):651–661PubMed
6.
go back to reference Haid RW Jr (2001) C1–C2 transarticular screw fixation: technical aspects. Neurosurgery 49(1):71–74PubMed Haid RW Jr (2001) C1–C2 transarticular screw fixation: technical aspects. Neurosurgery 49(1):71–74PubMed
7.
go back to reference Richter M, Schmidt R, Claes L, Puhl W, Wilke HJ (2002) Posterior atlantoaxial fixation: biomechanical in vitro comparison of six different techniques. Spine (Phila Pa 1976) 27(16):1724–1732CrossRef Richter M, Schmidt R, Claes L, Puhl W, Wilke HJ (2002) Posterior atlantoaxial fixation: biomechanical in vitro comparison of six different techniques. Spine (Phila Pa 1976) 27(16):1724–1732CrossRef
8.
9.
go back to reference Luther N, Iorgulescu JB, Geannette C, Gebhard H, Saleh T, Tsiouris AJ, Hartl R (2013) Comparison of navigated versus non-navigated pedicle screw placement in 260 patients and 1434 screws: screw accuracy, screw size, and the complexity of surgery. J Spinal Disord Tech. doi:10.1097/BSD.0b013e31828af33e Luther N, Iorgulescu JB, Geannette C, Gebhard H, Saleh T, Tsiouris AJ, Hartl R (2013) Comparison of navigated versus non-navigated pedicle screw placement in 260 patients and 1434 screws: screw accuracy, screw size, and the complexity of surgery. J Spinal Disord Tech. doi:10.​1097/​BSD.​0b013e31828af33e​
10.
go back to reference Nakashima H, Yukawa Y, Imagama S, Kanemura T, Kamiya M, Yanase M, Ito K, Machino M, Yoshida G, Ishikawa Y, Matsuyama Y, Ishiguro N, Kato F (2012) Complications of cervical pedicle screw fixation for nontraumatic lesions: a multicenter study of 84 patients. J Neurosurg Spine 16(3):238–247. doi:10.3171/2011.11.SPINE11102 CrossRefPubMed Nakashima H, Yukawa Y, Imagama S, Kanemura T, Kamiya M, Yanase M, Ito K, Machino M, Yoshida G, Ishikawa Y, Matsuyama Y, Ishiguro N, Kato F (2012) Complications of cervical pedicle screw fixation for nontraumatic lesions: a multicenter study of 84 patients. J Neurosurg Spine 16(3):238–247. doi:10.​3171/​2011.​11.​SPINE11102 CrossRefPubMed
11.
go back to reference Richter M, Cakir B, Schmidt R (2005) Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws. Spine (Phila Pa 1976) 30(20):2280–2287CrossRef Richter M, Cakir B, Schmidt R (2005) Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws. Spine (Phila Pa 1976) 30(20):2280–2287CrossRef
14.
go back to reference Denis F (1983) The three column spine and its significance in the classification of acute thoracolumbar spinal injuries. Spine (Phila Pa 1976) 8(8):817–831CrossRef Denis F (1983) The three column spine and its significance in the classification of acute thoracolumbar spinal injuries. Spine (Phila Pa 1976) 8(8):817–831CrossRef
16.
go back to reference Hartig D, Batke J, Dea N, Kelly A, Fisher C, Street J (2015) Adverse events in surgically treated cervical spondylopathic myelopathy: a prospective validated observational study. Spine (Phila Pa 1976) 40(5):292–298. doi:10.1097/BRS.0000000000000755 CrossRef Hartig D, Batke J, Dea N, Kelly A, Fisher C, Street J (2015) Adverse events in surgically treated cervical spondylopathic myelopathy: a prospective validated observational study. Spine (Phila Pa 1976) 40(5):292–298. doi:10.​1097/​BRS.​0000000000000755​ CrossRef
17.
go back to reference Macagno A, Liu S, Marascalchi BJ, Yang S, Boniello AJ, Bendo JA, Lafage VC, Passias PG (2015) Perioperative risks associated with cervical spondylotic myelopathy based on surgical treatment strategies. Int J Spine Surg 9:24. doi:10.14444/2024 PubMedPubMedCentral Macagno A, Liu S, Marascalchi BJ, Yang S, Boniello AJ, Bendo JA, Lafage VC, Passias PG (2015) Perioperative risks associated with cervical spondylotic myelopathy based on surgical treatment strategies. Int J Spine Surg 9:24. doi:10.​14444/​2024 PubMedPubMedCentral
19.
go back to reference Koller H, Acosta F, Tauber M, Fox M, Martin H, Forstner R, Augat P, Penzkofer R, Pirich C, Kassmann H, Resch H, Hitzl W (2008) Cervical anterior transpedicular screw fixation (ATPS)—part II. Accuracy of manual insertion and pull-out strength of ATPS. Eur Spine J 17(4):539–555. doi:10.1007/s00586-007-0573-x CrossRefPubMedPubMedCentral Koller H, Acosta F, Tauber M, Fox M, Martin H, Forstner R, Augat P, Penzkofer R, Pirich C, Kassmann H, Resch H, Hitzl W (2008) Cervical anterior transpedicular screw fixation (ATPS)—part II. Accuracy of manual insertion and pull-out strength of ATPS. Eur Spine J 17(4):539–555. doi:10.​1007/​s00586-007-0573-x CrossRefPubMedPubMedCentral
20.
go back to reference Aramomi M, Masaki Y, Koshizuka S, Kadota R, Okawa A, Koda M, Yamazaki M (2008) Anterior pedicle screw fixation for multilevel cervical corpectomy and spinal fusion. Acta Neurochir (Wien) 150(6):575–582. doi:10.1007/s00701-008-1574-1 (discussion 582) CrossRef Aramomi M, Masaki Y, Koshizuka S, Kadota R, Okawa A, Koda M, Yamazaki M (2008) Anterior pedicle screw fixation for multilevel cervical corpectomy and spinal fusion. Acta Neurochir (Wien) 150(6):575–582. doi:10.​1007/​s00701-008-1574-1 (discussion 582) CrossRef
21.
23.
24.
go back to reference Caglar YS, Torun F, Pait TG, Hogue W, Bozkurt M, Ozgen S (2005) Biomechanical comparison of inside–outside screws, cables, and regular screws, using a sawbone model. Neurosurg Rev 28(1):53–58. doi:10.1007/s10143-004-0350-9 PubMed Caglar YS, Torun F, Pait TG, Hogue W, Bozkurt M, Ozgen S (2005) Biomechanical comparison of inside–outside screws, cables, and regular screws, using a sawbone model. Neurosurg Rev 28(1):53–58. doi:10.​1007/​s10143-004-0350-9 PubMed
27.
go back to reference Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine (Phila Pa 1976) 15(1):11–14CrossRef Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine (Phila Pa 1976) 15(1):11–14CrossRef
29.
30.
go back to reference Bredow J, Oppermann J, Kraus B, Schiller P, Schiffer G, Sobottke R, Eysel P, Koy T (2015) The accuracy of 3D fluoroscopy-navigated screw insertion in the upper and subaxial cervical spine. Eur Spine J. doi:10.1007/s00586-015-3974-2 Bredow J, Oppermann J, Kraus B, Schiller P, Schiffer G, Sobottke R, Eysel P, Koy T (2015) The accuracy of 3D fluoroscopy-navigated screw insertion in the upper and subaxial cervical spine. Eur Spine J. doi:10.​1007/​s00586-015-3974-2
31.
go back to reference Zhao L, Li G, Liu J, Benedict GM, Ebraheim NA, Ma W, Sun S, Xu R, Ruan C (2014) Radiological studies on the best entry point and trajectory of anterior cervical pedicle screw in the lower cervical spine. Eur Spine J 23(10):2175–2181. doi:10.1007/s00586-014-3473-x CrossRefPubMed Zhao L, Li G, Liu J, Benedict GM, Ebraheim NA, Ma W, Sun S, Xu R, Ruan C (2014) Radiological studies on the best entry point and trajectory of anterior cervical pedicle screw in the lower cervical spine. Eur Spine J 23(10):2175–2181. doi:10.​1007/​s00586-014-3473-x CrossRefPubMed
Metadata
Title
Accuracy of 3D fluoroscopy-navigated anterior transpedicular screw insertion in the cervical spine: an experimental study
Authors
Jan Bredow
Carolin Meyer
Max Joseph Scheyerer
Florian Siedek
Lars Peter Müller
Peer Eysel
Gregor Stein
Publication date
01-06-2016
Publisher
Springer Berlin Heidelberg
Published in
European Spine Journal / Issue 6/2016
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-016-4403-x

Other articles of this Issue 6/2016

European Spine Journal 6/2016 Go to the issue