Background

Once surgical management is indicated, variation of Ebstein valve morphology affects surgical strategy. This study explored practical, easily measureable, cardiovascular magnetic resonance (CMR)-derived attributes that may contribute to the complexity and risk of cone reconstruction.

Methods

A retrospective assessment was performed of Ebstein anomaly patients older than 12 years age, with pre-operative CMR, undergoing cone surgical reconstruction by one surgeon. In addition to clinical data, the CMR-derived Ebstein valve rotation angle (EVRA), area ratios of chamber size, indexed functional RV (RVEDVi) and left ventricular (LV) volumes, tricuspid valve regurgitant fraction (TR%) and other valve attributes were related to early surgical outcome; including death, significant residual TR% or breakdown of repair.

Results

Of 26 operated patients older than 12 years age, since program start, 20 had pre-op CMR and underwent surgery at median (range) age 20 (14–57) years. TR% was improved in all patients. Four of the 20 CMR patients (20%) experienced early surgical dehiscence of the paravalve tissue, with cone-shaped tricuspid valve intact; one of whom died.
A larger EVRA correlated with Carpentier category and was significantly related to dehiscence. If EVRA >60o, relative risk of dehiscence was 3.2 (CI 1.3–4.9, p = 0.03). Those with dehiscence had thickened, more tethered anterior leaflet edges (RR 17, CI 3–100, p < 0.01), smaller pre-operative functional RVEDVi; (132 vs 177 mL/m2, p = 0.04), and were older (median 38 vs 19 years, p = 0.01). TR %, chamber area ratios and LV parameters were not different.

Conclusions

Comprehensive CMR assessment characterizes patients prior to cone surgical reconstruction of Ebstein anomaly. Pragmatic observation of larger EVRA, smaller RVEDVi and leaflet thickening, suggests risk of repair tension and dehiscence, and may require specific modification of cone surgical technique, such as leaflet augmentation.
Appendix
Available only for authorised users
Literature
1.
go back to reference Dearani JA, Danielson GK. Congenital heart surgery nomenclature and database project: Ebstein's anomaly and tricuspid valve disease. Ann Thorac Surg. 2000;69(4 Suppl):S106–17.CrossRef Dearani JA, Danielson GK. Congenital heart surgery nomenclature and database project: Ebstein's anomaly and tricuspid valve disease. Ann Thorac Surg. 2000;69(4 Suppl):S106–17.CrossRef
2.
go back to reference Attenhofer Jost CH, Connolly HM, Edwards WD, Hayes D, Warnes CA, Danielson GK. Ebstein's anomaly - review of a multifaceted congenital cardiac condition. Swiss Med Wkly. 2005;135(19–20):269–81 doi:2005/19/smw-10985.PubMed Attenhofer Jost CH, Connolly HM, Edwards WD, Hayes D, Warnes CA, Danielson GK. Ebstein's anomaly - review of a multifaceted congenital cardiac condition. Swiss Med Wkly. 2005;135(19–20):269–81 doi:2005/19/smw-10985.PubMed
4.
go back to reference Silva JP, Silva Lda F, Moreira LF, Lopez LM, Franchi SM, Lianza AC, et al. Cone reconstruction in Ebstein's anomaly repair: early and long-term results. Arq Bras Cardiol. 2011;97(3):199–208.CrossRef Silva JP, Silva Lda F, Moreira LF, Lopez LM, Franchi SM, Lianza AC, et al. Cone reconstruction in Ebstein's anomaly repair: early and long-term results. Arq Bras Cardiol. 2011;97(3):199–208.CrossRef
8.
go back to reference Carpentier A, Chauvaud S, Mace L, Relland J, Mihaileanu S, Marino JP, et al. A new reconstructive operation for Ebstein's anomaly of the tricuspid valve. J Thorac Cardiovasc Surg. 1988;96(1):92–101.PubMed Carpentier A, Chauvaud S, Mace L, Relland J, Mihaileanu S, Marino JP, et al. A new reconstructive operation for Ebstein's anomaly of the tricuspid valve. J Thorac Cardiovasc Surg. 1988;96(1):92–101.PubMed
9.
go back to reference Celermajer DS, Cullen S, Sullivan ID, Spiegelhalter DJ, Wyse RK, Deanfield JE. Outcome in neonates with Ebstein's anomaly. J Am Coll Cardiol. 1992;19(5):1041–6.CrossRef Celermajer DS, Cullen S, Sullivan ID, Spiegelhalter DJ, Wyse RK, Deanfield JE. Outcome in neonates with Ebstein's anomaly. J Am Coll Cardiol. 1992;19(5):1041–6.CrossRef
10.
go back to reference Hosch O, Sohns JM, Nguyen TT, Lauerer P, Rosenberg C, Kowallick JT, et al. The total right/left-volume index: a new and simplified cardiac magnetic resonance measure to evaluate the severity of Ebstein anomaly of the tricuspid valve: a comparison with heart failure markers from various modalities. Circ Cardiovasc Imaging. 2014;7(4):601–9. https://doi.org/10.1161/CIRCIMAGING.113.001467.CrossRefPubMed Hosch O, Sohns JM, Nguyen TT, Lauerer P, Rosenberg C, Kowallick JT, et al. The total right/left-volume index: a new and simplified cardiac magnetic resonance measure to evaluate the severity of Ebstein anomaly of the tricuspid valve: a comparison with heart failure markers from various modalities. Circ Cardiovasc Imaging. 2014;7(4):601–9. https://​doi.​org/​10.​1161/​CIRCIMAGING.​113.​001467.CrossRefPubMed
16.
go back to reference Schreiber C, Cook A, Ho SY, Augustin N, Anderson RH. Morphologic spectrum of Ebstein's malformation: revisitation relative to surgical repair. J Thorac Cardiovasc Surg. 1999;117(1):148–55.CrossRef Schreiber C, Cook A, Ho SY, Augustin N, Anderson RH. Morphologic spectrum of Ebstein's malformation: revisitation relative to surgical repair. J Thorac Cardiovasc Surg. 1999;117(1):148–55.CrossRef
Metadata
Title
A simple measure of the extent of Ebstein valve rotation with cardiovascular magnetic resonance gives a practical guide to feasibility of surgical cone reconstruction
Authors
Marina L. Hughes
Beatrice Bonello
Preeti Choudhary
Jan Marek
Victor Tsang
Publication date
01-12-2019
Publisher
BioMed Central
Published in
Journal of Cardiovascular Magnetic Resonance / Issue 1/2019
Electronic ISSN: 1532-429X
DOI
https://doi.org/10.1186/s12968-019-0546-3

Other articles of this Issue 1/2019

Journal of Cardiovascular Magnetic Resonance 1/2019 Go to the issue