A novel software tool for semi-automatic quantification of thoracic aorta dilatation on baseline and follow-up computed tomography angiography

Authors: Xinpei Gao, Sara Boccalini, Pieter H. Kitslaar, Ricardo P. J. Budde, Shengxian Tu, Boudewijn P. F. Lelieveldt, Jouke Dijkstra, Johan H. C. Reiber

Published in: The International Journal of Cardiovascular Imaging | Issue 4/2019

Login to get access

Abstract

A dedicated software package that could semi-automatically assess differences in aortic maximal cross-sectional diameters from consecutive CT scans would most likely reduce the post-processing time and effort by the physicians. The aim of this study was to present and assess the quality of a new tool for the semi-automatic quantification of thoracic aorta dilation dimensions. Twenty-nine patients with two CTA scans of the thoracic aorta for which the official clinical report indicated an increase in aortic diameters were included in the study. Aortic maximal cross-sectional diameters of baseline and follow-up studies generated semi-automatically by the software were compared with corresponding manual measurements. The semi-automatic measurements were performed at seven landmarks defined on the baseline scan by two operators. Bias, Bland–Altman plots and intraclass correlation coefficients were calculated between the two methods and, for the semi-automatic software, also between two observers. The average time difference between the two scans of a single patient was 1188 ± 622 days. For the semi-automatic software, in 2 out of 29 patients, manual interaction was necessary; in the remaining 27 patients (93.1%), semi-automatic results were generated, demonstrating excellent intraclass correlation coefficients (all values ≥ 0.91) and small differences, especially for the proximal aortic arch (baseline: 0.19 ± 1.30 mm; follow-up: 0.44 ± 2.21 mm), the mid descending aorta (0.37 ± 1.64 mm; 0.37 ± 2.06 mm), and the diaphragm (0.30 ± 1.14 mm; 0.37 ± 1.80 mm). The inter-observer variability was low with all errors in diameters ≤ 1 mm, and intraclass correlation coefficients all ≥ 0.95. The semi-automatic tool decreased the processing time by 40% (13 vs. 22 min). In this work, a semi-automatic software package that allows the assessment of thoracic aorta diameters from baseline and follow-up CTs (and their differences), was presented, and demonstrated high accuracy and low inter-observer variability.
Literature
1.
go back to reference Erbel R, Aboyans V, Boileau C et al (2014) ESC Guidelines on the diagnosis and treatment of aortic diseases: document covering acute and chronic aortic diseases of the thoracic and abdominal aorta of the adult. The Task Force for the Diagnosis and Treatment of Aortic Diseases of the European. Eur Heart J 35(41):2873–2926. https://doi.org/10.1093/eurheartj/ehu281 CrossRefPubMed Erbel R, Aboyans V, Boileau C et al (2014) ESC Guidelines on the diagnosis and treatment of aortic diseases: document covering acute and chronic aortic diseases of the thoracic and abdominal aorta of the adult. The Task Force for the Diagnosis and Treatment of Aortic Diseases of the European. Eur Heart J 35(41):2873–2926. https://​doi.​org/​10.​1093/​eurheartj/​ehu281 CrossRefPubMed
2.
go back to reference Hiratzka LF, Bakris GL, Beckman J et al (2010) ACCF/AHA/AATS/ACR/ASA/SCA/SCAI/SIR/STS/SVM guidelines for the diagnosis and management of patients with thoracic aortic disease: a report of the American College of Cardiology Foundation/American heart association task force on practice guidelines. Circulation 121(13):e266–e369. https://doi.org/10.1161/CIR.0b013e3181d4739e CrossRefPubMed Hiratzka LF, Bakris GL, Beckman J et al (2010) ACCF/AHA/AATS/ACR/ASA/SCA/SCAI/SIR/STS/SVM guidelines for the diagnosis and management of patients with thoracic aortic disease: a report of the American College of Cardiology Foundation/American heart association task force on practice guidelines. Circulation 121(13):e266–e369. https://​doi.​org/​10.​1161/​CIR.​0b013e3181d4739e​ CrossRefPubMed
7.
go back to reference Lu T-LC, Rizzo E, Marques-Vidal PM, Segesser LKv, Dehmeshki J, Qanadli SD (2010) Variability of ascending aorta diameter measurements as assessed with electrocardiography-gated multidetector computerized tomography and computer assisted diagnosis software. Interact Cardiovasc Thorac Surg 10(2):217–221. https://doi.org/10.1510/icvts.2009.216275 CrossRefPubMed Lu T-LC, Rizzo E, Marques-Vidal PM, Segesser LKv, Dehmeshki J, Qanadli SD (2010) Variability of ascending aorta diameter measurements as assessed with electrocardiography-gated multidetector computerized tomography and computer assisted diagnosis software. Interact Cardiovasc Thorac Surg 10(2):217–221. https://​doi.​org/​10.​1510/​icvts.​2009.​216275 CrossRefPubMed
9.
go back to reference Gao X, Tu S, de Graaf MA et al (2014) Automatic extraction of arterial centerline from whole-body computed tomography angiographic datasets. Comput Cardiol IEEE 2014:697–700 Gao X, Tu S, de Graaf MA et al (2014) Automatic extraction of arterial centerline from whole-body computed tomography angiographic datasets. Comput Cardiol IEEE 2014:697–700
10.
go back to reference Kitslaar PH, van’t Klooster R, Staring M, Lelieveldt BPF, van der Geest RJ (2015) Segmentation of branching vascular structures using adaptive subdivision surface fitting. In: Medical imaging 2015: image processing Vol 9413, 94133Z. https://doi.org/10.1117/12.2082222 Kitslaar PH, van’t Klooster R, Staring M, Lelieveldt BPF, van der Geest RJ (2015) Segmentation of branching vascular structures using adaptive subdivision surface fitting. In: Medical imaging 2015: image processing Vol 9413, 94133Z. https://​doi.​org/​10.​1117/​12.​2082222
11.
go back to reference Klein S, Staring M, Murphy K et al (2010) Elastix: a toolbox for intensity-based medical image registration. IEEE Trans Med Imaging 29(1):196–205CrossRefPubMed Klein S, Staring M, Murphy K et al (2010) Elastix: a toolbox for intensity-based medical image registration. IEEE Trans Med Imaging 29(1):196–205CrossRefPubMed
12.
go back to reference Gao X, Kitslaar PH, Budde RPJ et al (2016) Automatic detection of aorto-femoral vessel trajectory from whole-body computed tomography angiography data sets. Int J Cardiovasc Imaging 32(8):1311–1322CrossRefPubMed Gao X, Kitslaar PH, Budde RPJ et al (2016) Automatic detection of aorto-femoral vessel trajectory from whole-body computed tomography angiography data sets. Int J Cardiovasc Imaging 32(8):1311–1322CrossRefPubMed
15.
go back to reference Martínez-Mera JA, Tahoces PG, Carreira JM, Suárez-Cuenca JJ, Souto M (2013) A hybrid method based on level set and 3D region growing for segmentation of the thoracic aorta. Comput Aided Surg 18(5–6):109–117CrossRefPubMed Martínez-Mera JA, Tahoces PG, Carreira JM, Suárez-Cuenca JJ, Souto M (2013) A hybrid method based on level set and 3D region growing for segmentation of the thoracic aorta. Comput Aided Surg 18(5–6):109–117CrossRefPubMed
16.
go back to reference Vitanovski D, Ralovich K, Ionasec R et al (2012) Personalized learning-based segmentation of thoracic aorta and main branches for diagnosis and treatment planning[C]//Biomedical Imaging (ISBI), 2012 9th IEEE International Symposium on. IEEE, 836–839 Vitanovski D, Ralovich K, Ionasec R et al (2012) Personalized learning-based segmentation of thoracic aorta and main branches for diagnosis and treatment planning[C]//Biomedical Imaging (ISBI), 2012 9th IEEE International Symposium on. IEEE, 836–839
17.
go back to reference Kovács T, Cattin P, Alkadhi H, Wildermuth S, Székely G (2006) Automatic segmentation of the vessel lumen from 3D CTA images of aortic dissection. In: Bildverarbeitung für die Medizin 2006. Springer, Berlin, pp 161–165CrossRef Kovács T, Cattin P, Alkadhi H, Wildermuth S, Székely G (2006) Automatic segmentation of the vessel lumen from 3D CTA images of aortic dissection. In: Bildverarbeitung für die Medizin 2006. Springer, Berlin, pp 161–165CrossRef
Metadata
Title
A novel software tool for semi-automatic quantification of thoracic aorta dilatation on baseline and follow-up computed tomography angiography
Authors
Xinpei Gao
Sara Boccalini
Pieter H. Kitslaar
Ricardo P. J. Budde
Shengxian Tu
Boudewijn P. F. Lelieveldt
Jouke Dijkstra
Johan H. C. Reiber
Publication date
01-04-2019
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 4/2019
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-018-1488-9

Other articles of this Issue 4/2019

The International Journal of Cardiovascular Imaging 4/2019 Go to the issue