Skip to main content
Top
Published in: EJNMMI Research 1/2018

Open Access 01-12-2018 | Original research

A new methodology to derive 3D kinetic parametric FDG PET images based on a mathematical approach integrating an error model of measurement

Authors: Elyse Colard, Sarkis Delcourt, Laetitia Padovani, Sébastien Thureau, Arthur Dumouchel, Pierrick Gouel, Justine Lequesne, Bardia Farman Ara, Pierre Vera, David Taïeb, Isabelle Gardin, Dominique Barbolosi, Sébastien Hapdey

Published in: EJNMMI Research | Issue 1/2018

Login to get access

Abstract

Background

In FDG-PET, SUV images are hampered by large potential biases. Our aim was to develop an alternative method (ParaPET) to generate 3D kinetic parametric FDG-PET images easy to perform in clinical oncology.

Methods

The key points of our method are the use of a new error model of PET measurement extracted from a late dynamic PET acquisition of 15 min, centered over the lesion and an image-derived input function (IDIF). The 15-min acquisition is reconstructed to obtain five images of FDG mean activity concentration and images of its variance to model errors of PET measurement. Our approach is carried out on each voxel to derive 3D kinetic parameter images. ParaPET was evaluated and compared to Patlak analysis as a reference. Hunter and Barbolosi methods (Barbolosi-Bl: with blood samples or Barbolosi-Im: with IDIF) were also investigated and compared to Patlak. Our evaluation was carried on Ki index, the net influx rate and its maximum value in the lesion (Ki,max).

Results

This parameter was obtained from 41 non-small cell lung cancer lesions associated with 4 to 5 blood samples per patient, required for the Patlak analysis. Compare to Patlak, the median relative difference and associated range (median; [min;max]) in Ki,max estimates were not statistically significant (Wilcoxon test) for ParaPET (− 3.0%; [− 31.9%; 47.3%]; p = 0.08) but statistically significant for Barbolosi-Bl (− 8.0%; [− 30.8%; 53.7%]; p = 0.001), Barbolosi-Im (− 7.9%; [− 38.4%; 30.6%]; p = 0.007) or Hunter (32.8%; [− 14.6%; 132.2%]; p < 10− 5). In the Bland-Altman plots, the ratios between the four methods and Patlak are not dependent of the Ki magnitude, except for Hunter. The 95% limits of agreement are comparable for ParaPET (34.7%), Barbolosi-Bl (30.1%) and Barbolosi-Im (30.8%), lower to Hunter (81.1%). In the 25 lesions imaged before and during the radio-chemotherapy, the decrease in the FDG uptake (ΔSUVmax or ΔKi,max) is statistically more important (p < 0.02, Wilcoxon one-tailed test) when estimated from the Ki images than from the SUV images (additional median variation of − 2.3% [− 52.6%; + 19.1%] for ΔKi,max compared to ΔSUVmax).

Conclusion

None of the four methodologies is yet ready to replace the Patlak approach, and further improvements are still required. Nevertheless, ParaPET remains a promising approach, offering a non-invasive alternative to methods based on multiple blood samples and only requiring a late PET acquisition. It allows deriving Ki values, highly correlated and presenting the lowest relative bias with Patlak estimates, in comparison to the other methods we evaluated. Moreover, ParaPET gives access to quantitative information at the pixel level, which needs to be evaluated in the perspective of radiomic and tumour response.

Trial registration

NCT 02821936; May 2016.
Literature
1.
go back to reference Edet-Sanson A, Dubray B, Doyeux K, et al. Serial assessment of FDG-PET FDG uptake and functional volume during radiotherapy (RT) in patients with non-small cell lung cancer (NSCLC). Radiother Oncol. 2012;102:251–7.CrossRef Edet-Sanson A, Dubray B, Doyeux K, et al. Serial assessment of FDG-PET FDG uptake and functional volume during radiotherapy (RT) in patients with non-small cell lung cancer (NSCLC). Radiother Oncol. 2012;102:251–7.CrossRef
2.
go back to reference Boellaard R. Standards for PET image acquisition and quantitative data analysis. J Nucl Med. 2009;50(Suppl 1):11S–20S.CrossRef Boellaard R. Standards for PET image acquisition and quantitative data analysis. J Nucl Med. 2009;50(Suppl 1):11S–20S.CrossRef
3.
go back to reference Keyes JWJ. SUV: standard uptake or silly useless value? J Nucl Med. 1995;36:1836–9.PubMed Keyes JWJ. SUV: standard uptake or silly useless value? J Nucl Med. 1995;36:1836–9.PubMed
4.
go back to reference Weber WA, Gatsonis CA, Mozley PD, et al. Repeatability of 18F-FDG PET/CT in advanced non-small cell lung cancer: prospective assessment in two multicenter trials. J Nucl Med. 2015;56(8):1137–43.CrossRef Weber WA, Gatsonis CA, Mozley PD, et al. Repeatability of 18F-FDG PET/CT in advanced non-small cell lung cancer: prospective assessment in two multicenter trials. J Nucl Med. 2015;56(8):1137–43.CrossRef
5.
go back to reference Sokoloff L, Reivich M, Kennedy C, et al. The [14C]Deoxyglucose method for the measurement of local cerebral glucose utilization: theory, procedure and normal values in the consious and anesthetized albino rat. J Neurochem. 1977;28:897–916.CrossRef Sokoloff L, Reivich M, Kennedy C, et al. The [14C]Deoxyglucose method for the measurement of local cerebral glucose utilization: theory, procedure and normal values in the consious and anesthetized albino rat. J Neurochem. 1977;28:897–916.CrossRef
6.
go back to reference Patlak CS, Blasberg RG, Fenstermacher JD. Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. J Cereb Blood Flow Metab. 1983;3:1–7.CrossRef Patlak CS, Blasberg RG, Fenstermacher JD. Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. J Cereb Blood Flow Metab. 1983;3:1–7.CrossRef
7.
go back to reference Cheebsumon P, Velasquez LM, Hoekstra CJ, et al. Measuring response to therapy using FDG PET: semi-quantitative and full kinetic analysis. Eur J Nucl Med Mol Imaging. 2011;38:832–42.CrossRef Cheebsumon P, Velasquez LM, Hoekstra CJ, et al. Measuring response to therapy using FDG PET: semi-quantitative and full kinetic analysis. Eur J Nucl Med Mol Imaging. 2011;38:832–42.CrossRef
8.
go back to reference de Geus-Oei LF, Visser EP, Krabbe PF, et al. Comparison of image-derived and arterial input functions for estimating the rate of glucose metabolism in therapy-monitoring 18F-FDG PET studies. J Nucl Med. 2006;47:945–9.PubMed de Geus-Oei LF, Visser EP, Krabbe PF, et al. Comparison of image-derived and arterial input functions for estimating the rate of glucose metabolism in therapy-monitoring 18F-FDG PET studies. J Nucl Med. 2006;47:945–9.PubMed
9.
go back to reference Gambhir SS, Schwaiger M, Huang SC, et al. Simple noninvasive quantification method for measuring myocardial glucose utilization in humans employing positron emission tomography and fluorine-18 deoxyglucose. J Nucl Med. 1989;30:359–66.PubMed Gambhir SS, Schwaiger M, Huang SC, et al. Simple noninvasive quantification method for measuring myocardial glucose utilization in humans employing positron emission tomography and fluorine-18 deoxyglucose. J Nucl Med. 1989;30:359–66.PubMed
10.
go back to reference Ohtake T, Kosaka N, Watanabe T, et al. Noninvasive method to obtain input function for measuring tissue glucose utilization of thoracic and abdominal organs. J Nucl Med. 1991;32:1432–8.PubMed Ohtake T, Kosaka N, Watanabe T, et al. Noninvasive method to obtain input function for measuring tissue glucose utilization of thoracic and abdominal organs. J Nucl Med. 1991;32:1432–8.PubMed
11.
go back to reference Hapdey S, Buvat I, Carson JM, Carrasquillo JA, Whatley M, Bacharach SL. Searching for alternatives to full kinetic analysis in 18F-FDG PET: an extension of the simplified kinetic analysis method. J Nucl Med. 2011;52:634–41.CrossRef Hapdey S, Buvat I, Carson JM, Carrasquillo JA, Whatley M, Bacharach SL. Searching for alternatives to full kinetic analysis in 18F-FDG PET: an extension of the simplified kinetic analysis method. J Nucl Med. 2011;52:634–41.CrossRef
12.
go back to reference Hunter GJ, Hamberg LM, Alpert NM, Choi NC, Fischman AJ. Simplified measurment of deoxyglucose utilization rate. J Nucl Med. 1996;37:950–5.PubMed Hunter GJ, Hamberg LM, Alpert NM, Choi NC, Fischman AJ. Simplified measurment of deoxyglucose utilization rate. J Nucl Med. 1996;37:950–5.PubMed
13.
go back to reference Barbolosi D, Hapdey S, Battini S, et al. Determination of the unmetabolised F-FDG fraction by using an extension of simplified kinetic analysis method: clinical evaluation in paragangliomas. Med Biol Eng Comput. 2015;54(1):103–11.CrossRef Barbolosi D, Hapdey S, Battini S, et al. Determination of the unmetabolised F-FDG fraction by using an extension of simplified kinetic analysis method: clinical evaluation in paragangliomas. Med Biol Eng Comput. 2015;54(1):103–11.CrossRef
14.
go back to reference Kamasak ME, Bouman CA, Morris ED, Sauer K. Direct reconstruction of kinetic parameter images from dynamic PET data. IEEE Trans Med Imaging. 2005;24:636–50.CrossRef Kamasak ME, Bouman CA, Morris ED, Sauer K. Direct reconstruction of kinetic parameter images from dynamic PET data. IEEE Trans Med Imaging. 2005;24:636–50.CrossRef
15.
go back to reference Karakatsanis NA, Casey ME, Lodge MA, Rahmim A, Zaidi H. Whole-body direct 4D parametric PET imaging employing nested generalized Patlak expectation-maximization reconstruction. Phys Med Biol. 2016;61:5456–85.CrossRef Karakatsanis NA, Casey ME, Lodge MA, Rahmim A, Zaidi H. Whole-body direct 4D parametric PET imaging employing nested generalized Patlak expectation-maximization reconstruction. Phys Med Biol. 2016;61:5456–85.CrossRef
16.
go back to reference Hoekstra CJ, Hoekstra OS, Stroobants SG, et al. Methods to monitor response to chemotherapy in non-small cell lung cancer with 18F-FDG PET. J Nucl Med. 2002;43:1304–9.PubMed Hoekstra CJ, Hoekstra OS, Stroobants SG, et al. Methods to monitor response to chemotherapy in non-small cell lung cancer with 18F-FDG PET. J Nucl Med. 2002;43:1304–9.PubMed
17.
go back to reference Tixier F, Hatt M, Le Rest CC, le PA CL, Visvikis D. Reproducibility of tumor uptake heterogeneity characterization through textural feature analysis in 18F-FDG PET. J Nucl Med. 2012;53:693–700.CrossRef Tixier F, Hatt M, Le Rest CC, le PA CL, Visvikis D. Reproducibility of tumor uptake heterogeneity characterization through textural feature analysis in 18F-FDG PET. J Nucl Med. 2012;53:693–700.CrossRef
18.
go back to reference Young H, Baum R, Cremerius U, et al. Measurement of clinical and subclinical tumour response using [18F]-fluorodeoxyglucose and positron emission tomography: review and 1999 EORTC recommendations. European Organization for Research and Treatment of Cancer (EORTC) PET Study Group. Eur J Cancer. 1999;35:1773–82.CrossRef Young H, Baum R, Cremerius U, et al. Measurement of clinical and subclinical tumour response using [18F]-fluorodeoxyglucose and positron emission tomography: review and 1999 EORTC recommendations. European Organization for Research and Treatment of Cancer (EORTC) PET Study Group. Eur J Cancer. 1999;35:1773–82.CrossRef
19.
go back to reference Strauss LG, Pan L, Cheng C, Haberkorn U, Dimitrakopoulou-Strauss A. Shortened acquisition protocols for the quantitative assessment of the 2-tissue-compartment model using dynamic PET/CT 18F-FDG studies. J Nucl Med. 2011;52:379–85.CrossRef Strauss LG, Pan L, Cheng C, Haberkorn U, Dimitrakopoulou-Strauss A. Shortened acquisition protocols for the quantitative assessment of the 2-tissue-compartment model using dynamic PET/CT 18F-FDG studies. J Nucl Med. 2011;52:379–85.CrossRef
20.
go back to reference Visser EP, Kienhorst LBE, de Geus-Oei LF, Oyen WJG. Shortened dynamic FDG-PET protocol to determine the glucose metabolic rate in non-small cell lung carcinoma. IEEE Nucl Sci Symp Conf Rec. 2008:4455–8. Visser EP, Kienhorst LBE, de Geus-Oei LF, Oyen WJG. Shortened dynamic FDG-PET protocol to determine the glucose metabolic rate in non-small cell lung carcinoma. IEEE Nucl Sci Symp Conf Rec. 2008:4455–8.
21.
go back to reference Huang J, O'Sullivan F. An analysis of whole body tracer kinetics in dynamic PET studies with application to image-based blood input function extraction. IEEE Trans Med Imaging. 2014;33:1093–108.CrossRef Huang J, O'Sullivan F. An analysis of whole body tracer kinetics in dynamic PET studies with application to image-based blood input function extraction. IEEE Trans Med Imaging. 2014;33:1093–108.CrossRef
22.
go back to reference Padovani L, Baret A, Ciccolini J, et al. An alternative parameter for early forecasting clinical response in NSCLC patients during radiotherapy: proof of concept study. Br J Radiol. 2016;89:20160061.CrossRef Padovani L, Baret A, Ciccolini J, et al. An alternative parameter for early forecasting clinical response in NSCLC patients during radiotherapy: proof of concept study. Br J Radiol. 2016;89:20160061.CrossRef
23.
go back to reference Buvat I. A non-parametric bootstrap approach for analysing the statistical properties of SPECT and PET images. Phys Med Biol. 2002;47:1761–75.CrossRef Buvat I. A non-parametric bootstrap approach for analysing the statistical properties of SPECT and PET images. Phys Med Biol. 2002;47:1761–75.CrossRef
24.
go back to reference Freedman N, Sundaram SK, Kurdziel K, et al. Comparison of SUV and Patlak slope for monitoring of cancer therapy using serial PET scans. Eur J Nucl Med. 2003;30:46–53.CrossRef Freedman N, Sundaram SK, Kurdziel K, et al. Comparison of SUV and Patlak slope for monitoring of cancer therapy using serial PET scans. Eur J Nucl Med. 2003;30:46–53.CrossRef
25.
go back to reference Kotasidis FA, Tsoumpas C, Rahmim A. Advanced kinetic modelling strategies: towards adoption in clinical PET imaging. Clin Transl Imaging. 2014;2:219–37.CrossRef Kotasidis FA, Tsoumpas C, Rahmim A. Advanced kinetic modelling strategies: towards adoption in clinical PET imaging. Clin Transl Imaging. 2014;2:219–37.CrossRef
Metadata
Title
A new methodology to derive 3D kinetic parametric FDG PET images based on a mathematical approach integrating an error model of measurement
Authors
Elyse Colard
Sarkis Delcourt
Laetitia Padovani
Sébastien Thureau
Arthur Dumouchel
Pierrick Gouel
Justine Lequesne
Bardia Farman Ara
Pierre Vera
David Taïeb
Isabelle Gardin
Dominique Barbolosi
Sébastien Hapdey
Publication date
01-12-2018
Publisher
Springer Berlin Heidelberg
Published in
EJNMMI Research / Issue 1/2018
Electronic ISSN: 2191-219X
DOI
https://doi.org/10.1186/s13550-018-0454-9

Other articles of this Issue 1/2018