Skip to main content
Top
Published in: Pediatric Cardiology 4/2021

Open Access 01-04-2021 | Letter to the Editor

A Deeper Understanding of Physics, Physiology, Experimental Methodology, and Statistics is Essential for Valid Comparison of USCOM 1A and cMRI

Authors: Rob Phillips, Joe Brierley

Published in: Pediatric Cardiology | Issue 4/2021

Login to get access

Excerpt

Weissbach et al. [1] make a number of assumptions related to cardiovascular physiology, physics, experimental methodology, and statistics which impair the strength of their conclusions in comparing the USCOM 1A digital Doppler ultrasound and cMRI for measurement of hemodynamics in adolescents with heart disease. …
Literature
3.
go back to reference Ihlen H, Amlie JP, Dale J, Forfang K, Nitter-Hauge S, Otterstad JE, Simonsen S, Myhre E (1984) Determination of cardiac output by Doppler echocardiography. Br Heart J 51:54–60CrossRef Ihlen H, Amlie JP, Dale J, Forfang K, Nitter-Hauge S, Otterstad JE, Simonsen S, Myhre E (1984) Determination of cardiac output by Doppler echocardiography. Br Heart J 51:54–60CrossRef
4.
go back to reference Zhang Z, Lu B, Sheng X, Jin N (2011) Accuracy of stroke volume variation for predicting fluid responsiveness: a systematic review and meta-analysis. J Anesth 25(6):904–916CrossRef Zhang Z, Lu B, Sheng X, Jin N (2011) Accuracy of stroke volume variation for predicting fluid responsiveness: a systematic review and meta-analysis. J Anesth 25(6):904–916CrossRef
5.
go back to reference Langewourters GJ, Wesseling KH, Godehard WJA (1984) The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new model. J Biomech 17(6):425–435CrossRef Langewourters GJ, Wesseling KH, Godehard WJA (1984) The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new model. J Biomech 17(6):425–435CrossRef
8.
go back to reference Bland JM, Altman DG (1999) Measuring agreement in method comparison studies. Stat Methods Med Res 8:135–160CrossRef Bland JM, Altman DG (1999) Measuring agreement in method comparison studies. Stat Methods Med Res 8:135–160CrossRef
Metadata
Title
A Deeper Understanding of Physics, Physiology, Experimental Methodology, and Statistics is Essential for Valid Comparison of USCOM 1A and cMRI
Authors
Rob Phillips
Joe Brierley
Publication date
01-04-2021
Publisher
Springer US
Published in
Pediatric Cardiology / Issue 4/2021
Print ISSN: 0172-0643
Electronic ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-021-02604-2

Other articles of this Issue 4/2021

Pediatric Cardiology 4/2021 Go to the issue