Skip to main content
Top
Published in: International Orthopaedics 2/2015

01-02-2015 | Original Article

A convertible shoulder system: is it useful in total shoulder arthroplasty revisions?

Authors: Jean Kany, Thomas Amouyel, Olivier Flamand, Denis Katz, Philippe Valenti

Published in: International Orthopaedics | Issue 2/2015

Login to get access

Abstract

Purpose

The frequency of total shoulder arthroplasty (TSA) implantation is constantly increasing. This leads to revisions because of stem or glenoid component loosening, infection, instability or glenoid subsidence. Significant rotator cuff lesions and/or bone loss necessitate reverse shoulder arthroplasty (RSA) with bone reconstruction, which is a demanding procedure.
Our hypothesis is that a platform system (versatile humeral stem with metal back glenoid component) makes revision surgery less demanding and less time consuming, and helps reduce the risks of complication. The purpose of this study is to analyse our revision experience with such a system to support our hypothesis.

Methods

We present 29 revision cases of a convertible platform shoulder system: five hemi arthroplasties (HA), eight TSA with cemented glenoid (TSACG) and 16 TSA with metal backed glenoid component (TSAMB).
Three TSACG were switched to TSAMB, and 26 other arthroplasties were switched to RSA. The pre-operative Constant score was 27 (range, 0–38). Our revision incidence was 5.4 % (29 revisions out of 537 shoulder arthroplasties over five years).

Results

At revision, Constant score was 60 (range, 42–85). The humeral stem (versatile with TSA and RSA) was kept in three out of four cases. Most of the time it was changed because of too high a position, making it impossible to reduce the RSA. Nevertheless, 12 PTAMB were switched in 12 RSA without any metal backed revisions.

Conclusion

A platform shoulder system allows much easier revisions.
Literature
1.
go back to reference Torchia ME, Cofield RH, Settergren CR (1997) Total shoulder arthroplasty with the Neer prosthesis: long-term results. J Should Elb Surg 6:495–505CrossRef Torchia ME, Cofield RH, Settergren CR (1997) Total shoulder arthroplasty with the Neer prosthesis: long-term results. J Should Elb Surg 6:495–505CrossRef
2.
9.
go back to reference Gohlke F, Rolf O (2007) Revision of failed fracture hemiarthroplasties to reverse total shoulder prosthesis through the transhumeral approach : method incorporating a pectoralis-major-pedicled bone window. Oper Orthop Traumatol 19:185–208. doi:10.1007/s00064-007-1202-x PubMedCrossRef Gohlke F, Rolf O (2007) Revision of failed fracture hemiarthroplasties to reverse total shoulder prosthesis through the transhumeral approach : method incorporating a pectoralis-major-pedicled bone window. Oper Orthop Traumatol 19:185–208. doi:10.​1007/​s00064-007-1202-x PubMedCrossRef
11.
go back to reference Neer CS, Morrison DS (1988) Glenoid bone-grafting in total shoulder arthroplasty. J Bone Joint Surg Am 70:1154–1162PubMed Neer CS, Morrison DS (1988) Glenoid bone-grafting in total shoulder arthroplasty. J Bone Joint Surg Am 70:1154–1162PubMed
12.
go back to reference Taunton MJ, McIntosh AL, Sperling JW, Cofield RH (2008) Total shoulder arthroplasty with a metal-backed, bone-ingrowth glenoid component. Medium to long-term results. J Bone Joint Surg Am 90:2180–2188. doi:10.2106/JBJS.G.00966 PubMedCrossRef Taunton MJ, McIntosh AL, Sperling JW, Cofield RH (2008) Total shoulder arthroplasty with a metal-backed, bone-ingrowth glenoid component. Medium to long-term results. J Bone Joint Surg Am 90:2180–2188. doi:10.​2106/​JBJS.​G.​00966 PubMedCrossRef
13.
go back to reference Boileau P, Avidor C, Krishnan SG et al (2002) Cemented polyethylene versus uncemented metal-backed glenoid components in total shoulder arthroplasty: a prospective, double-blind, randomized study. J Should Elb Surg 11:351–359. doi:10.1067/mse.2002.125807 CrossRef Boileau P, Avidor C, Krishnan SG et al (2002) Cemented polyethylene versus uncemented metal-backed glenoid components in total shoulder arthroplasty: a prospective, double-blind, randomized study. J Should Elb Surg 11:351–359. doi:10.​1067/​mse.​2002.​125807 CrossRef
14.
go back to reference Lazarus MD, Jensen KL, Southworth C, Matsen FA (2002) The radiographic evaluation of keeled and pegged glenoid component insertion. J Bone Joint Surg Am 84-A:1174–1182PubMed Lazarus MD, Jensen KL, Southworth C, Matsen FA (2002) The radiographic evaluation of keeled and pegged glenoid component insertion. J Bone Joint Surg Am 84-A:1174–1182PubMed
18.
go back to reference Valenti P, Valle P, Sauzieres P et al (2014) Uncemented metal-back glenoid component in revision of aseptic glenoid loosening: a prospective study of 10 cases with a minimum follow-up of 2 years. Arch Orthop Trauma Surg 134:785–791. doi:10.1007/s00402-014-1971-2 PubMedCrossRef Valenti P, Valle P, Sauzieres P et al (2014) Uncemented metal-back glenoid component in revision of aseptic glenoid loosening: a prospective study of 10 cases with a minimum follow-up of 2 years. Arch Orthop Trauma Surg 134:785–791. doi:10.​1007/​s00402-014-1971-2 PubMedCrossRef
19.
go back to reference Sanchez-Sotelo J, Sperling JW, Rowland CM, Cofield RH (2003) Instability after shoulder arthroplasty: results of surgical treatment. J Bone Joint Surg Am 85-A:622–631PubMed Sanchez-Sotelo J, Sperling JW, Rowland CM, Cofield RH (2003) Instability after shoulder arthroplasty: results of surgical treatment. J Bone Joint Surg Am 85-A:622–631PubMed
21.
go back to reference Boileau P, Krishnan SG, Tinsi L et al (2002) Tuberosity malposition and migration: reasons for poor outcomes after hemiarthroplasty for displaced fractures of the proximal humerus. J Should Elb Surg 11:401–412. doi:10.1067/mse.2002.124527 CrossRef Boileau P, Krishnan SG, Tinsi L et al (2002) Tuberosity malposition and migration: reasons for poor outcomes after hemiarthroplasty for displaced fractures of the proximal humerus. J Should Elb Surg 11:401–412. doi:10.​1067/​mse.​2002.​124527 CrossRef
22.
go back to reference Demirhan M, Kilicoglu O, Altinel L et al (2003) Prognostic factors in prosthetic replacement for acute proximal humerus fractures. J Orthop Trauma 17:181–188, discussion 188–189 Demirhan M, Kilicoglu O, Altinel L et al (2003) Prognostic factors in prosthetic replacement for acute proximal humerus fractures. J Orthop Trauma 17:181–188, discussion 188–189
24.
go back to reference Levy JC, Virani N, Pupello D, Frankle M (2007) Use of the reverse shoulder prosthesis for the treatment of failed hemiarthroplasty in patients with glenohumeral arthritis and rotator cuff deficiency. J Bone Joint Surg (Br) 89:189–195. doi:10.1302/0301-620X.89B2.18161 CrossRef Levy JC, Virani N, Pupello D, Frankle M (2007) Use of the reverse shoulder prosthesis for the treatment of failed hemiarthroplasty in patients with glenohumeral arthritis and rotator cuff deficiency. J Bone Joint Surg (Br) 89:189–195. doi:10.​1302/​0301-620X.​89B2.​18161 CrossRef
Metadata
Title
A convertible shoulder system: is it useful in total shoulder arthroplasty revisions?
Authors
Jean Kany
Thomas Amouyel
Olivier Flamand
Denis Katz
Philippe Valenti
Publication date
01-02-2015
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 2/2015
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-014-2563-z

Other articles of this Issue 2/2015

International Orthopaedics 2/2015 Go to the issue