Skip to main content
Top
Published in: Journal of Clinical Monitoring and Computing 2/2015

01-04-2015 | Original Research

A comprehensive operating room information system using the Kinect sensors and RFID

Authors: Mahyar Taghizadeh Nouei, Ali Vahidian Kamyad, Ahmad Reza Soroush, Somayeh Ghazalbash

Published in: Journal of Clinical Monitoring and Computing | Issue 2/2015

Login to get access

Abstract

Occasionally, surgeons do need various types of information to be available rapidly, efficiently and safely during surgical procedures. Meanwhile, they need to free up hands throughout the surgery to necessarily access the mouse to control any application in the sterility mode. In addition, they are required to record audio as well as video files, and enter and save some data. This is an attempt to develop a comprehensive operating room information system called “Medinav” to tackle all mentioned issues. An integrated and comprehensive operating room information system is introduced to be compatible with Health Level 7 (HL7) and digital imaging and communications in medicine (DICOM). DICOM is a standard for handling, storing, printing, and transmitting information in medical imaging. Besides, a natural user interface (NUI) is designed specifically for operating rooms where touch-less interactions with finger and hand tracking are in use. Further, the system could both record procedural data automatically, and view acquired information from multiple perspectives graphically. A prototype system is tested in a live operating room environment at an Iranian teaching hospital. There are also contextual interviews and usability satisfaction questionnaires conducted with the “MediNav” system to investigate how useful the proposed system could be. The results reveal that integration of these systems into a complete solution is the key to not only stream up data and workflow but maximize surgical team usefulness as well. It is now possible to comprehensively collect and visualize medical information, and access a management tool with a touch-less NUI in a rather quick, practical, and harmless manner.
Literature
1.
go back to reference Meyer MA. Use of location data for the surveillance, analysis, and optimization of clinical processes Massachusetts Institute of Technology 2006. Meyer MA. Use of location data for the surveillance, analysis, and optimization of clinical processes Massachusetts Institute of Technology 2006.
2.
go back to reference Meyer M, Levine W, Egan M, Cohen B, Spitz G, Garcia P, Chueh H, Sandberg W. A computerized perioperative data integration and display system. Int J Comput Assist Radiol Surg. 2007;2:191–202.CrossRef Meyer M, Levine W, Egan M, Cohen B, Spitz G, Garcia P, Chueh H, Sandberg W. A computerized perioperative data integration and display system. Int J Comput Assist Radiol Surg. 2007;2:191–202.CrossRef
3.
go back to reference Ruppert GC, Reis LO, Amorim PH, de Moraes TF, da Silva JV. Touchless gesture user interface for interactive image visualization in urological surgery. World J Urol. 2012;30:687–91.CrossRefPubMed Ruppert GC, Reis LO, Amorim PH, de Moraes TF, da Silva JV. Touchless gesture user interface for interactive image visualization in urological surgery. World J Urol. 2012;30:687–91.CrossRefPubMed
4.
go back to reference Wachs J, Stern H, Edan Y, Gillam M, Handler J, Feied C, Smith M. A gesture-based tool for sterile browsing of radiology images. J Am Med Inform Assoc. 2008;15:321–3.CrossRefPubMedCentralPubMed Wachs J, Stern H, Edan Y, Gillam M, Handler J, Feied C, Smith M. A gesture-based tool for sterile browsing of radiology images. J Am Med Inform Assoc. 2008;15:321–3.CrossRefPubMedCentralPubMed
5.
go back to reference Wu HQ, Lv ZM, Geng XY, Jiang K, Tang LM, Zhou GM, Dong JC. Interoperative fundus image and report sharing in compliance with integrating the healthcare enterprise conformance and web access to digital imaging and communication in medicine persistent object protocol. Int J Ophthalmol. 2013;6(6):879–83. doi:10.3980/j.issn.2222-3959.2013.06.24.PubMedCentralPubMed Wu HQ, Lv ZM, Geng XY, Jiang K, Tang LM, Zhou GM, Dong JC. Interoperative fundus image and report sharing in compliance with integrating the healthcare enterprise conformance and web access to digital imaging and communication in medicine persistent object protocol. Int J Ophthalmol. 2013;6(6):879–83. doi:10.​3980/​j.​issn.​2222-3959.​2013.​06.​24.PubMedCentralPubMed
6.
go back to reference Blake J. Manning early access program natural user interface version 8. Manning Publications Co. 2011. Blake J. Manning early access program natural user interface version 8. Manning Publications Co. 2011.
7.
go back to reference Chi H-L, Kang S-C, Wang X. Research trends and opportunities of augmented reality applications in architecture, engineering, and construction. Autom Constr. 2013;33:116–22.CrossRef Chi H-L, Kang S-C, Wang X. Research trends and opportunities of augmented reality applications in architecture, engineering, and construction. Autom Constr. 2013;33:116–22.CrossRef
8.
go back to reference Wigdor D, Wixon D. Brave NUI world: designing natural user interfaces for touch and gesture. USA: Elsevier; 2011. Wigdor D, Wixon D. Brave NUI world: designing natural user interfaces for touch and gesture. USA: Elsevier; 2011.
11.
go back to reference Bogdan O, Alin C, Aurel V, Serban M. Integrated medical system using DICOM and HL7 standards. In: Lazinica A editor. New advanced technologies. InTech; 2010 pp. 232–246. Bogdan O, Alin C, Aurel V, Serban M. Integrated medical system using DICOM and HL7 standards. In: Lazinica A editor. New advanced technologies. InTech; 2010 pp. 232–246.
13.
go back to reference Lewis JR. IBM computer usability satisfaction questionnaires: psychometric evaluation and instructions for use. Int J Hum Comput Interact. 1995;7:57–78.CrossRef Lewis JR. IBM computer usability satisfaction questionnaires: psychometric evaluation and instructions for use. Int J Hum Comput Interact. 1995;7:57–78.CrossRef
14.
go back to reference Wachs J, Stern H, Edan Y, Gillam M, Feied C, Smith M, Handler J. Gestix: a doctor-computer sterile gesture interface for dynamic environments. In: Soft computing in industrial applications. Berlin: Springer; 2007. pp. 30–39. Wachs J, Stern H, Edan Y, Gillam M, Feied C, Smith M, Handler J. Gestix: a doctor-computer sterile gesture interface for dynamic environments. In: Soft computing in industrial applications. Berlin: Springer; 2007. pp. 30–39.
15.
go back to reference Gratzel C, Fong T, Grange S, Baur C. A non-contact mouse for surgeon-computer interaction. Technol Health Care. 2004;12:245–57.PubMed Gratzel C, Fong T, Grange S, Baur C. A non-contact mouse for surgeon-computer interaction. Technol Health Care. 2004;12:245–57.PubMed
18.
go back to reference Ebert LC, Hatch G, Thali MJ, Ross S. Invisible touch-control of a DICOM viewer with finger gestures using the Kinect depth camera. J Forensic Radiol Imaging 1:10–14. Ebert LC, Hatch G, Thali MJ, Ross S. Invisible touch-control of a DICOM viewer with finger gestures using the Kinect depth camera. J Forensic Radiol Imaging 1:10–14.
19.
go back to reference Anacleto J, Fels S, Silvestre R. Transforming a paper based process to a natural user interfaces process in a Chronic Care Hospital. Procedia Comput Sci. 2012;14:173–80.CrossRef Anacleto J, Fels S, Silvestre R. Transforming a paper based process to a natural user interfaces process in a Chronic Care Hospital. Procedia Comput Sci. 2012;14:173–80.CrossRef
20.
go back to reference Liu CCH, Chang C-H, Su M-C, Chu H-T, Hung S-H, Wong J-M, Wang P-C. RFID-initiated workflow control to facilitate patient safety and utilization efficiency in operation theater. Comput Methods Programs Biomed. 2011;104:435–42.CrossRefPubMed Liu CCH, Chang C-H, Su M-C, Chu H-T, Hung S-H, Wong J-M, Wang P-C. RFID-initiated workflow control to facilitate patient safety and utilization efficiency in operation theater. Comput Methods Programs Biomed. 2011;104:435–42.CrossRefPubMed
21.
go back to reference Kranzfelder M, Zywitza D, Jell T, Schneider A, Gillen S, Friess H, Feussner H. Real-time monitoring for detection of retained surgical sponges and team motion in the surgical operation room using radio-frequency-identification (RFID) technology: a preclinical evaluation. J Surg Res. 2012;175(2):191–8. doi:10.1016/j.jss.2011.03.029.CrossRefPubMed Kranzfelder M, Zywitza D, Jell T, Schneider A, Gillen S, Friess H, Feussner H. Real-time monitoring for detection of retained surgical sponges and team motion in the surgical operation room using radio-frequency-identification (RFID) technology: a preclinical evaluation. J Surg Res. 2012;175(2):191–8. doi:10.​1016/​j.​jss.​2011.​03.​029.CrossRefPubMed
22.
go back to reference Voruganti A, Mayoral R, Vazquez A, Burgert, O. A modular video streaming method for surgical assistance in operating room networks. Int J Comput Assist Radiol Surg 5:489–499. Voruganti A, Mayoral R, Vazquez A, Burgert, O. A modular video streaming method for surgical assistance in operating room networks. Int J Comput Assist Radiol Surg 5:489–499.
23.
go back to reference Taniguchi A, Nakamura E, Yaegashi K. Introduction of a simple audio recording system to the operating room–experience at a small local hospital. Masui. 2012;61(10):1156–8.PubMed Taniguchi A, Nakamura E, Yaegashi K. Introduction of a simple audio recording system to the operating room–experience at a small local hospital. Masui. 2012;61(10):1156–8.PubMed
24.
go back to reference Orza B, Cordos A, Vlaicu A, Meza S, Petrovan B. An integrated eHealth system using medical information standards. In: Proceedings of the 14th WSEAS international conference on computers: part of the 14th WSEAS CSCC multiconference-Volume I. World Scientific and Engineering Academy and Society (WSEAS), pp. 63–68. Orza B, Cordos A, Vlaicu A, Meza S, Petrovan B. An integrated eHealth system using medical information standards. In: Proceedings of the 14th WSEAS international conference on computers: part of the 14th WSEAS CSCC multiconference-Volume I. World Scientific and Engineering Academy and Society (WSEAS), pp. 63–68.
25.
go back to reference Ang S. Experience with an innovative operating room dashboard system to improve quality and efficiency in an Academic Medical Center in Singapore. Anaesth Intensive Care. 2013;41(6):821.PubMed Ang S. Experience with an innovative operating room dashboard system to improve quality and efficiency in an Academic Medical Center in Singapore. Anaesth Intensive Care. 2013;41(6):821.PubMed
26.
go back to reference Nagy PG, Konewko R, Warnock M, Bernstein W, Seagull J, Xiao Y, George I, Park A. Novel, web-based, information-exploration approach for improving operating room logistics and system processes. Surg Innov. 2008;15:7–16.CrossRefPubMed Nagy PG, Konewko R, Warnock M, Bernstein W, Seagull J, Xiao Y, George I, Park A. Novel, web-based, information-exploration approach for improving operating room logistics and system processes. Surg Innov. 2008;15:7–16.CrossRefPubMed
27.
go back to reference Jacobs B, Duncan JR, Street M, Murray D. Audio and video recording system for routine documentation of fluoroscopic procedures. J Vasc Interv Radiol. 2010;21(5):725–9. Jacobs B, Duncan JR, Street M, Murray D. Audio and video recording system for routine documentation of fluoroscopic procedures. J Vasc Interv Radiol. 2010;21(5):725–9.
Metadata
Title
A comprehensive operating room information system using the Kinect sensors and RFID
Authors
Mahyar Taghizadeh Nouei
Ali Vahidian Kamyad
Ahmad Reza Soroush
Somayeh Ghazalbash
Publication date
01-04-2015
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 2/2015
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-014-9591-5

Other articles of this Issue 2/2015

Journal of Clinical Monitoring and Computing 2/2015 Go to the issue

Letter to Editor

To the Editor