In-line pressure within a HOTLINE® Fluid Warmer, under various flow conditions

Authors: Midoriko Higashi, Ken Yamaura, Yukie Matsubara, Takuya Fukudome, Sumio Hoka

Published in: Journal of Clinical Monitoring and Computing | Issue 2/2015

Login to get access

Abstract

Roller pump infusion devices are widely used for rapid infusion, and may be combined with separate warming devices. There may be instances however, where the pressures generated by the roller pump may not be compatible with the warming device. We assessed a commonly used roller pump in combination with a HOTLINE® Fluid Warmer, and found that it could generate pressures exceeding the HOTLINE® manufacturers specifications. This was of concern because the HOTLINE® manufacturer guideline states that not for use with pressure devices generating over 300 mmHg. Pressure greater than 300 mmHg may compromise the integrity of the HOTLINE® Fluid Warming Set. The aim of this study was to compare in-line pressure within a HOTLINE® Fluid Warmer at different infusion rates of a roller pump using various sizes of intravenous cannulae. The rapid infusion system comprised a 500 mL-normal saline bag, roller pump type infusion device, HOTLINE® Fluid Warmer (blood and fluid warmer system), and six different sizes of intravenous cannulae. In-line pressure was measured proximal to the HOTLINE® (pre-warmer) and proximal to the cannula (post-warmer), at flow rate of 50–160 mL/min. The in-line pressures increased significantly with increasing flow rate. The pre-warmer pressures exceeded 300 mmHg when the flow rate was ≥120 mL/min with 20-gauge, 48 mm length cannula, 130 with 20-gauge, 25 mm cannula, and 160 mL/min with 18-gauge, 48 mm cannula. However, they were <300 mmHg at any flow rates with 18-gauge, 30 mm cannula and 16-gauge cannulae. The post-warmer pressures exceeded 300 mmHg at the flow rate of 140 mL/min with 20-gauge, 48 mm cannula, and 160 mL/min with 20-gauge, 25 mm cannula, while they were <300 mmHg at any flow rates with 18 and 16-gauge cannulae. The in-line pressure within a HOTLINE® could exceed 300 mmHg, depending on the flow rate and size and length of cannula. It is important to pay attention to the size and length of cannulae and flow rate to keep the maximum in-line pressure <300 mmHg when a roller pump type infusion device is used.
Literature
1.
2.
go back to reference Schmied H, Kurz A, Sessler DI, Kozek S, Reiter A. Mild hypothermia increases blood loss and transfusion requirements during total hip arthroplasty. Lancet. 1996;347:289–92.CrossRefPubMed Schmied H, Kurz A, Sessler DI, Kozek S, Reiter A. Mild hypothermia increases blood loss and transfusion requirements during total hip arthroplasty. Lancet. 1996;347:289–92.CrossRefPubMed
3.
go back to reference Kurz A, Sessler DI, Lenhardt R. Perioperative normothermia to reduce the incidence of surgical-wound infection and shorten hostpitalization. Study of Wound Infection and Temperature Group. N Engl J Med. 1996;334:1209–15.CrossRefPubMed Kurz A, Sessler DI, Lenhardt R. Perioperative normothermia to reduce the incidence of surgical-wound infection and shorten hostpitalization. Study of Wound Infection and Temperature Group. N Engl J Med. 1996;334:1209–15.CrossRefPubMed
4.
go back to reference Frank SM, Fleisher LA, Breslow MJ, Higgins MS, Olson KF, Kelly S, Beattie C. Perioperative maintenance of normothermia reduces the incidence of morbid cardiac events. A randomized clinical trial. JAMA. 1997;277:1127–34.CrossRefPubMed Frank SM, Fleisher LA, Breslow MJ, Higgins MS, Olson KF, Kelly S, Beattie C. Perioperative maintenance of normothermia reduces the incidence of morbid cardiac events. A randomized clinical trial. JAMA. 1997;277:1127–34.CrossRefPubMed
5.
go back to reference Hotline® Fluid Warming Set: REF L-70 [package insert] Smiths Medical ASD, Inc., MA, USA. Hotline® Fluid Warming Set: REF L-70 [package insert] Smiths Medical ASD, Inc., MA, USA.
6.
go back to reference Patel N, Knapke DM, Smith CE, Napora TE, Pinchak AC, Hagen JF. Simulated clinical evaluation of conventional and newer fluid-warming devices. Anesth Analg. 1996;82:517–24.PubMed Patel N, Knapke DM, Smith CE, Napora TE, Pinchak AC, Hagen JF. Simulated clinical evaluation of conventional and newer fluid-warming devices. Anesth Analg. 1996;82:517–24.PubMed
7.
go back to reference Horowitz PE, Delagarza MA, Pulaski JJ, Smith RA. Flow rates and warming efficacy with Hotline and Ranger blood/fluid warmers. Anesth Analg. 2004;99:788–92.CrossRefPubMed Horowitz PE, Delagarza MA, Pulaski JJ, Smith RA. Flow rates and warming efficacy with Hotline and Ranger blood/fluid warmers. Anesth Analg. 2004;99:788–92.CrossRefPubMed
8.
go back to reference Smart CM, Primrose CW, Peters AL, Speirits EJ. The properties of an improvised piston pump for the rapid delivery of intravenous fluids. Anaesthesia. 2014;69:110–7. Smart CM, Primrose CW, Peters AL, Speirits EJ. The properties of an improvised piston pump for the rapid delivery of intravenous fluids. Anaesthesia. 2014;69:110–7.
9.
go back to reference Goodie DB. The effect of manual bulb pump infusion systems on venous luminal pressure and vein wall integrity. Anesth Analg. 1995;80:552–6.PubMed Goodie DB. The effect of manual bulb pump infusion systems on venous luminal pressure and vein wall integrity. Anesth Analg. 1995;80:552–6.PubMed
10.
go back to reference Mateer JR, Perry BW, Thompson BM, Tucker JF, Aprahamian CA. Effects of rapid infusion with high pressure and large-bore IV tubing on red blood cell lysis and warming. Ann Emerg Med. 1985;14:966–9.CrossRefPubMed Mateer JR, Perry BW, Thompson BM, Tucker JF, Aprahamian CA. Effects of rapid infusion with high pressure and large-bore IV tubing on red blood cell lysis and warming. Ann Emerg Med. 1985;14:966–9.CrossRefPubMed
Metadata
Title
In-line pressure within a HOTLINE® Fluid Warmer, under various flow conditions
Authors
Midoriko Higashi
Ken Yamaura
Yukie Matsubara
Takuya Fukudome
Sumio Hoka
Publication date
01-04-2015
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 2/2015
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-014-9605-3

Other articles of this Issue 2/2015

Journal of Clinical Monitoring and Computing 2/2015 Go to the issue

Letter to Editor

To the Editor