Skip to main content
Top
Published in: Heart and Vessels 7/2018

01-07-2018 | Original Article

3D-computed tomography to compare the dimensions of the left atrial appendage in patients with normal sinus rhythm and those with paroxysmal atrial fibrillation

Authors: Maiko Hozawa, Yoshihiro Morino, Yuki Matsumoto, Ryoichi Tanaka, Kyohei Nagata, Akiko Kumagai, Atsushi Tashiro, Akio Doi, Kunihiro Yoshioka

Published in: Heart and Vessels | Issue 7/2018

Login to get access

Abstract

Although paroxysmal atrial fibrillation (PAF) is an important cause of cardioembolic stroke, in contrast to chronic AF patients, the anatomical features of the left atrial appendage (LAA) in PAF patients remain unknown. Here, we investigated differences in LAA structures in patients with PAF and those with normal sinus rhythms (NSR) using 3D-computed tomography (3D-CT), which allows us to visualize complicated LAA structures at high spatial resolution. Study subjects were 30 consecutive PAF and 30 NSR patients with complete enhanced cardiac 3D-CT images available. After reconstruction of 3D LAA images, anatomical parameters of the LAA were measured and compared according to three proposed definitions of the LAA orifice plane determined by the following anatomical landmarks: DEF#1, center of warfarin ridge and centerline of proximal left circumflex artery; DEF#2, slope of warfarin ridge and mitral valve annulus; DEF#3, observers’ discretion by progressive rotation using the observers’ best estimate without the use of landmarks. The LAA volumes of the PAF groups were significantly greater than the NSR group according to all 3 definitions (DEF#1: 1.43 times, DEF#2: 1.44 times, and DEF#3: 1.36 times greater). The LAA orifice area was significantly larger in PAF than in NSR according to DEF#2, but was similar by DEF#1 and DEF#3. Intra-observer and inter-observer variations for any LAA measurements were very low. In conclusion, 3D-CT-based quantitative assessment of the LAA provides highly reproducible and detailed measurements, which can successfully discriminate differences of LAA volume between patients with NSR and those with PAF, suggesting significantly greater volumes in the latter.
Literature
1.
go back to reference Disertori M, Franzosi MG, Barlera S, Cosmi F, Quintarelli S, Favero C, Cappellini G, Fabbri G, Maggioni AP, Staszewsky L, Moroni LA, Latini R, Investigators G-A (2013) Thromboembolic event rate in paroxysmal and persistent atrial fibrillation: data from the GISSI-AF trial. BMC Cardiovasc Disord 13:28CrossRefPubMedPubMedCentral Disertori M, Franzosi MG, Barlera S, Cosmi F, Quintarelli S, Favero C, Cappellini G, Fabbri G, Maggioni AP, Staszewsky L, Moroni LA, Latini R, Investigators G-A (2013) Thromboembolic event rate in paroxysmal and persistent atrial fibrillation: data from the GISSI-AF trial. BMC Cardiovasc Disord 13:28CrossRefPubMedPubMedCentral
2.
go back to reference Agmon Y, Khandheria BK, Gentile F, Seward JB (1999) Echocardiographic assessment of the left atrial appendage. J Am Coll Cardiol 34:1867–1877CrossRefPubMed Agmon Y, Khandheria BK, Gentile F, Seward JB (1999) Echocardiographic assessment of the left atrial appendage. J Am Coll Cardiol 34:1867–1877CrossRefPubMed
3.
go back to reference Narumiya T, Sakamaki T, Sato Y, Kanmatsuse K (2003) Relationship between left atrial appendage function and left atrial thrombus in patients with nonvalvular chronic atrial fibrillation and atrial flutter. Circ J 67:68–72CrossRefPubMed Narumiya T, Sakamaki T, Sato Y, Kanmatsuse K (2003) Relationship between left atrial appendage function and left atrial thrombus in patients with nonvalvular chronic atrial fibrillation and atrial flutter. Circ J 67:68–72CrossRefPubMed
4.
go back to reference Burrell LD, Horne BD, Anderson JL, Muhlestein JB, Whisenant BK (2013) Usefulness of left atrial appendage volume as a predictor of embolic stroke in patients with atrial fibrillation. Am J Cardiol 112:1148–1152CrossRefPubMed Burrell LD, Horne BD, Anderson JL, Muhlestein JB, Whisenant BK (2013) Usefulness of left atrial appendage volume as a predictor of embolic stroke in patients with atrial fibrillation. Am J Cardiol 112:1148–1152CrossRefPubMed
5.
go back to reference Nucifora G, Faletra FF, Regoli F, Pasotti E, Pedrazzini G, Moccetti T, Auricchio A (2011) Evaluation of the left atrial appendage with real-time 3-dimensional transesophageal echocardiography: implications for catheter-based left atrial appendage closure. Circ Cardiovasc Imaging 4:514–523CrossRefPubMed Nucifora G, Faletra FF, Regoli F, Pasotti E, Pedrazzini G, Moccetti T, Auricchio A (2011) Evaluation of the left atrial appendage with real-time 3-dimensional transesophageal echocardiography: implications for catheter-based left atrial appendage closure. Circ Cardiovasc Imaging 4:514–523CrossRefPubMed
6.
go back to reference Matsumoto Y, Morino Y, Kumagai A, Hozawa M, Nakamura M, Terayama Y, Tashiro A (2017) Characteristics of anatomy and function of the left atrial appendage and their relationships in patients with cardioembolic stroke: a 3-dimensional transesophageal echocardiography study. J Stroke Cerebrovasc Dis 26:470–479CrossRefPubMed Matsumoto Y, Morino Y, Kumagai A, Hozawa M, Nakamura M, Terayama Y, Tashiro A (2017) Characteristics of anatomy and function of the left atrial appendage and their relationships in patients with cardioembolic stroke: a 3-dimensional transesophageal echocardiography study. J Stroke Cerebrovasc Dis 26:470–479CrossRefPubMed
7.
go back to reference Doi A, Takahashi H, Syuto B, Katayama M, Nagashima H, Okumura M (2013) Tailor-made plate design and manufacturing system for treating bone fractures in small animals. J Adv Comput Intell Intell Inform 17:1–10CrossRef Doi A, Takahashi H, Syuto B, Katayama M, Nagashima H, Okumura M (2013) Tailor-made plate design and manufacturing system for treating bone fractures in small animals. J Adv Comput Intell Intell Inform 17:1–10CrossRef
8.
go back to reference Budge LP, Shaffer KM, Moorman JR, Lake DE, Ferguson JD, Mangrum JM (2008) Analysis of in vivo left atrial appendage morphology in patients with atrial fibrillation: a direct comparison of transesophageal echocardiography, planar cardiac CT, and segmented three-dimensional cardiac CT. J Interv Card Electrophysiol 23:87–93CrossRefPubMed Budge LP, Shaffer KM, Moorman JR, Lake DE, Ferguson JD, Mangrum JM (2008) Analysis of in vivo left atrial appendage morphology in patients with atrial fibrillation: a direct comparison of transesophageal echocardiography, planar cardiac CT, and segmented three-dimensional cardiac CT. J Interv Card Electrophysiol 23:87–93CrossRefPubMed
9.
go back to reference Yosefy C, Laish-Farkash A, Azhibekov Y, Khalameizer V, Brodkin B, Katz A (2016) A new method for direct three-dimensional measurement of left atrial appendage dimensions during transesophageal echocardiography. Echocardiography 33:69–76CrossRefPubMed Yosefy C, Laish-Farkash A, Azhibekov Y, Khalameizer V, Brodkin B, Katz A (2016) A new method for direct three-dimensional measurement of left atrial appendage dimensions during transesophageal echocardiography. Echocardiography 33:69–76CrossRefPubMed
10.
go back to reference Mobius-Winkler S, Sandri M, Mangner N, Lurz P, Dahnert I, Schuler G (2012) The WATCHMAN left atrial appendage closure device for atrial fibrillation. J Vis Exp 60:3671 Mobius-Winkler S, Sandri M, Mangner N, Lurz P, Dahnert I, Schuler G (2012) The WATCHMAN left atrial appendage closure device for atrial fibrillation. J Vis Exp 60:3671
11.
go back to reference Masoudi FA, Calkins H, Kavinsky CJ, Drozda JP Jr, Gainsley P, Slotwiner DJ, Turi ZG (2015) 2015 ACC/HRS/SCAI left atrial appendage occlusion device societal overview. J Am Coll Cardiol 66:1497–1513CrossRefPubMed Masoudi FA, Calkins H, Kavinsky CJ, Drozda JP Jr, Gainsley P, Slotwiner DJ, Turi ZG (2015) 2015 ACC/HRS/SCAI left atrial appendage occlusion device societal overview. J Am Coll Cardiol 66:1497–1513CrossRefPubMed
12.
go back to reference Walker DT, Humphries JA, Phillips KP (2012) Anatomical analysis of the left atrial appendage using segmented, three-dimensional cardiac CT: a comparison of patients with paroxysmal and persistent forms of atrial fibrillation. J Interv Card Electrophysiol 34:173–179CrossRefPubMed Walker DT, Humphries JA, Phillips KP (2012) Anatomical analysis of the left atrial appendage using segmented, three-dimensional cardiac CT: a comparison of patients with paroxysmal and persistent forms of atrial fibrillation. J Interv Card Electrophysiol 34:173–179CrossRefPubMed
13.
go back to reference Imada M, Funabashi N, Asano M, Uehara M, Ueda M, Komuro I (2007) Anatomical remodeling of left atria in subjects with chronic and paroxysmal atrial fibrillation evaluated by multislice computed tomography. Int J Cardiol 119:384–388CrossRefPubMed Imada M, Funabashi N, Asano M, Uehara M, Ueda M, Komuro I (2007) Anatomical remodeling of left atria in subjects with chronic and paroxysmal atrial fibrillation evaluated by multislice computed tomography. Int J Cardiol 119:384–388CrossRefPubMed
14.
go back to reference Lacomis JM, Goitein O, Deible C, Moran PL, Mamone G, Madan S, Schwartzman D (2007) Dynamic multidimensional imaging of the human left atrial appendage. Europace 9:1134–1140CrossRefPubMed Lacomis JM, Goitein O, Deible C, Moran PL, Mamone G, Madan S, Schwartzman D (2007) Dynamic multidimensional imaging of the human left atrial appendage. Europace 9:1134–1140CrossRefPubMed
15.
go back to reference Ito T, Suwa M, Kobashi A, Yagi H, Hirota Y, Kawamura K (1998) Influence of altered loading conditions on left atrial appendage function in vivo. Am J Cardiol 81:1056–1059CrossRefPubMed Ito T, Suwa M, Kobashi A, Yagi H, Hirota Y, Kawamura K (1998) Influence of altered loading conditions on left atrial appendage function in vivo. Am J Cardiol 81:1056–1059CrossRefPubMed
16.
go back to reference Tabata T, Oki T, Yamada H, Abe M, Onose Y, Thomas JD (2000) Relationship between left atrial appendage function and plasma concentration of atrial natriuretic peptide. Eur J Echocardiogr 1:130–137CrossRefPubMed Tabata T, Oki T, Yamada H, Abe M, Onose Y, Thomas JD (2000) Relationship between left atrial appendage function and plasma concentration of atrial natriuretic peptide. Eur J Echocardiogr 1:130–137CrossRefPubMed
17.
go back to reference Di Biase L, Santangeli P, Anselmino M, Mohanty P, Salvetti I, Gili S, Horton R, Sanchez JE, Bai R, Mohanty S, Pump A, Cereceda Brantes M, Gallinghouse GJ, Burkhardt JD, Cesarani F, Scaglione M, Natale A, Gaita F (2012) Does the left atrial appendage morphology correlate with the risk of stroke in patients with atrial fibrillation? Results from a multicenter study. J Am Coll Cardiol 60:531–538CrossRefPubMed Di Biase L, Santangeli P, Anselmino M, Mohanty P, Salvetti I, Gili S, Horton R, Sanchez JE, Bai R, Mohanty S, Pump A, Cereceda Brantes M, Gallinghouse GJ, Burkhardt JD, Cesarani F, Scaglione M, Natale A, Gaita F (2012) Does the left atrial appendage morphology correlate with the risk of stroke in patients with atrial fibrillation? Results from a multicenter study. J Am Coll Cardiol 60:531–538CrossRefPubMed
18.
go back to reference Beutler DS, Gerkin RD, Loli AI (2014) The morphology of left atrial appendage lobes: a novel characteristic naming scheme derived through three-dimensional cardiac computed tomography. World J Cardiovasc Surg 4:17–24CrossRef Beutler DS, Gerkin RD, Loli AI (2014) The morphology of left atrial appendage lobes: a novel characteristic naming scheme derived through three-dimensional cardiac computed tomography. World J Cardiovasc Surg 4:17–24CrossRef
19.
go back to reference Wang Y, Di Biase L, Horton RP, Nguyen T, Morhanty P, Natale A (2010) Left atrial appendage studied by computed tomography to help planning for appendage closure device placement. J Cardiovasc Electrophysiol 21:973–982CrossRefPubMed Wang Y, Di Biase L, Horton RP, Nguyen T, Morhanty P, Natale A (2010) Left atrial appendage studied by computed tomography to help planning for appendage closure device placement. J Cardiovasc Electrophysiol 21:973–982CrossRefPubMed
20.
21.
go back to reference Taina M, Vanninen R, Hedman M, Jakala P, Karkkainen S, Tapiola T, Sipola P (2013) Left atrial appendage volume increased in more than half of patients with cryptogenic stroke. PLoS One 8:e79519CrossRefPubMedPubMedCentral Taina M, Vanninen R, Hedman M, Jakala P, Karkkainen S, Tapiola T, Sipola P (2013) Left atrial appendage volume increased in more than half of patients with cryptogenic stroke. PLoS One 8:e79519CrossRefPubMedPubMedCentral
22.
go back to reference Chung H, Jeon B, Chang HJ, Han D, Shim H, Cho IJ, Shim CY, Hong GR, Kim JS, Jang Y, Chung N (2015) Predicting peri-device leakage of left atrial appendage device closure using novel three-dimensional geometric CT analysis. J Cardiovasc Ultrasound 23:211–218CrossRefPubMedPubMedCentral Chung H, Jeon B, Chang HJ, Han D, Shim H, Cho IJ, Shim CY, Hong GR, Kim JS, Jang Y, Chung N (2015) Predicting peri-device leakage of left atrial appendage device closure using novel three-dimensional geometric CT analysis. J Cardiovasc Ultrasound 23:211–218CrossRefPubMedPubMedCentral
23.
go back to reference Holmes DR, Reddy VY, Turi ZG, Doshi SK, Sievert H, Buchbinder M, Mullin CM, Sick P, Investigators PA (2009) Percutaneous closure of the left atrial appendage versus warfarin therapy for prevention of stroke in patients with atrial fibrillation: a randomised non-inferiority trial. Lancet 374:534–542CrossRefPubMed Holmes DR, Reddy VY, Turi ZG, Doshi SK, Sievert H, Buchbinder M, Mullin CM, Sick P, Investigators PA (2009) Percutaneous closure of the left atrial appendage versus warfarin therapy for prevention of stroke in patients with atrial fibrillation: a randomised non-inferiority trial. Lancet 374:534–542CrossRefPubMed
24.
go back to reference Reddy VY, Doshi SK, Sievert H, Buchbinder M, Neuzil P, Huber K, Halperin JL, Holmes D, Investigators PA (2013) Percutaneous left atrial appendage closure for stroke prophylaxis in patients with atrial fibrillation: 2.3-Year Follow-up of the PROTECT AF (Watchman Left Atrial Appendage System for Embolic Protection in Patients with Atrial Fibrillation) Trial. Circulation 127:720–729CrossRefPubMed Reddy VY, Doshi SK, Sievert H, Buchbinder M, Neuzil P, Huber K, Halperin JL, Holmes D, Investigators PA (2013) Percutaneous left atrial appendage closure for stroke prophylaxis in patients with atrial fibrillation: 2.3-Year Follow-up of the PROTECT AF (Watchman Left Atrial Appendage System for Embolic Protection in Patients with Atrial Fibrillation) Trial. Circulation 127:720–729CrossRefPubMed
25.
go back to reference Otton JM, Spina R, Sulas R, Subbiah RN, Jacobs N, Muller DW, Gunalingam B (2015) Left atrial appendage closure guided by personalized 3D-printed cardiac reconstruction. JACC Cardiovasc Interv 8:1004–1006CrossRefPubMed Otton JM, Spina R, Sulas R, Subbiah RN, Jacobs N, Muller DW, Gunalingam B (2015) Left atrial appendage closure guided by personalized 3D-printed cardiac reconstruction. JACC Cardiovasc Interv 8:1004–1006CrossRefPubMed
26.
go back to reference Pracon R, Grygoruk R, Dzielinska Z, Kepka C, Dabrowska A, Konka M, Jazwiec P, Reczuch K, Witkowski A, Demkow M (2016) Percutaneous occlusion of the left atrial appendage with complex anatomy facilitated with 3D-printed model of the heart. EuroIntervention 12:927CrossRefPubMed Pracon R, Grygoruk R, Dzielinska Z, Kepka C, Dabrowska A, Konka M, Jazwiec P, Reczuch K, Witkowski A, Demkow M (2016) Percutaneous occlusion of the left atrial appendage with complex anatomy facilitated with 3D-printed model of the heart. EuroIntervention 12:927CrossRefPubMed
27.
go back to reference Boucebci S, Pambrun T, Velasco S, Duboe PO, Ingrand P, Tasu JP (2016) Assessment of normal left atrial appendage anatomy and function over gender and ages by dynamic cardiac CT. Eur Radiol 26:1512–1520CrossRefPubMed Boucebci S, Pambrun T, Velasco S, Duboe PO, Ingrand P, Tasu JP (2016) Assessment of normal left atrial appendage anatomy and function over gender and ages by dynamic cardiac CT. Eur Radiol 26:1512–1520CrossRefPubMed
28.
go back to reference Veinot JP, Harrity PJ, Gentile F, Khandheria BK, Bailey KR, Eickholt JT, Seward JB, Tajik AJ, Edwards WD (1997) Anatomy of the normal left atrial appendage: a quantitative study of age-related changes in 500 autopsy hearts: implications for echocardiographic examination. Circulation 96:3112–3115CrossRefPubMed Veinot JP, Harrity PJ, Gentile F, Khandheria BK, Bailey KR, Eickholt JT, Seward JB, Tajik AJ, Edwards WD (1997) Anatomy of the normal left atrial appendage: a quantitative study of age-related changes in 500 autopsy hearts: implications for echocardiographic examination. Circulation 96:3112–3115CrossRefPubMed
29.
go back to reference Erol B, Karcaaltincaba M, Aytemir K, Cay N, Hazirolan T, Akata D (2011) Analysis of left atrial appendix by dual-source CT coronary angiography: morphologic classification and imaging by volume rendered CT images. Eur J Radiol 80:e346–e350CrossRefPubMed Erol B, Karcaaltincaba M, Aytemir K, Cay N, Hazirolan T, Akata D (2011) Analysis of left atrial appendix by dual-source CT coronary angiography: morphologic classification and imaging by volume rendered CT images. Eur J Radiol 80:e346–e350CrossRefPubMed
30.
go back to reference Spencer RJ, DeJong P, Fahmy P, Lempereur M, Tsang MY, Gin KG, Lee PK, Nair P, Tsang TS, Jue J, Saw J (2015) Changes in left atrial appendage dimensions following volume loading during percutaneous left atrial appendage closure. JACC Cardiovasc Interv 8:1935–1941CrossRefPubMed Spencer RJ, DeJong P, Fahmy P, Lempereur M, Tsang MY, Gin KG, Lee PK, Nair P, Tsang TS, Jue J, Saw J (2015) Changes in left atrial appendage dimensions following volume loading during percutaneous left atrial appendage closure. JACC Cardiovasc Interv 8:1935–1941CrossRefPubMed
31.
go back to reference Fukushima K, Fukushima N, Kato K, Ejima K, Sato H, Fukushima K, Saito C, Hayashi K, Arai K, Manaka T, Ashihara K, Shoda M, Hagiwara N (2016) Correlation between left atrial appendage morphology and flow velocity in patients with paroxysmal atrial fibrillation. Eur Heart J Cardiovasc Imaging 17:59–66PubMed Fukushima K, Fukushima N, Kato K, Ejima K, Sato H, Fukushima K, Saito C, Hayashi K, Arai K, Manaka T, Ashihara K, Shoda M, Hagiwara N (2016) Correlation between left atrial appendage morphology and flow velocity in patients with paroxysmal atrial fibrillation. Eur Heart J Cardiovasc Imaging 17:59–66PubMed
Metadata
Title
3D-computed tomography to compare the dimensions of the left atrial appendage in patients with normal sinus rhythm and those with paroxysmal atrial fibrillation
Authors
Maiko Hozawa
Yoshihiro Morino
Yuki Matsumoto
Ryoichi Tanaka
Kyohei Nagata
Akiko Kumagai
Atsushi Tashiro
Akio Doi
Kunihiro Yoshioka
Publication date
01-07-2018
Publisher
Springer Japan
Published in
Heart and Vessels / Issue 7/2018
Print ISSN: 0910-8327
Electronic ISSN: 1615-2573
DOI
https://doi.org/10.1007/s00380-018-1119-3

Other articles of this Issue 7/2018

Heart and Vessels 7/2018 Go to the issue