Skip to main content
Top
Published in: Documenta Ophthalmologica 3/2019

01-06-2019 | Zonisamide | Original Research Article

Hand-held, dilation-free, electroretinography in children under 3 years of age treated with vigabatrin

Authors: Xiang Ji, Michelle McFarlane, Henry Liu, Annie Dupuis, Carol A. Westall

Published in: Documenta Ophthalmologica | Issue 3/2019

Login to get access

Abstract

Purpose

The anti-epileptic drug vigabatrin is associated with reduction in light-adapted 30-Hz flicker electroretinogram (ERG) amplitude. Ophthalmological assessments, including ERGs, monitor retinal health during vigabatrin treatment. RETeval™ is a hand-held ERG device adapted for dilation-free ERG assessment. To evaluate the usefulness of RETeval™ for vigabatrin ERG assessment, we evaluated intra-visit reliability and clinical feasibility of RETeval™ ERG assessment in children under 3 years of age undergoing vigabatrin treatment.

Methods

In this prospective study, children underwent 30-Hz flicker ERG assessment with RETeval™ before routine vigabatrin monitoring including sedated-ERG using the Espion E2 Colour Dome. Intraclass correlation coefficient (ICC) statistics identified the degree of intra-visit reliability from two repeated measurements of the same participant within one testing session. The omega squared (ω2) statistic identified the level of association between RETeval™ and Espion light-adapted 30-Hz flicker responses.

Results

Nine children completed RETeval™ ERG testing. The intra-visit ICCs for the RETeval™ 30-Hz flicker amplitude (µV) were high: 0.81 (right eye) and 0.86 (left eye), while the implicit times (ms) were 0.79 (right eye) and 0.42 (left eye). The RETeval™ 30-Hz flicker amplitude was positively associated with the Espion 30-Hz flicker response (ω2 = 0.71). The Bland–Altman plot showed no bias in the mean difference of amplitudes between the two systems.

Conclusion

This is the first study to assess the utility of RETeval™ device in children under 3 years of age undergoing vigabatrin treatment. RETeval™ demonstrated high intra-visit reliability with responses consistent with the standard Espion ERG. RETeval™ may be beneficial for assessment of retinal toxicity in young children treated with vigabatrin.
Literature
1.
go back to reference Riikonen R, Donner M (1979) Incidence and aetiology of infantile spasms from 1960 to 1976: a population study in Finland. Dev Med Child Neurol 21:333–343CrossRefPubMed Riikonen R, Donner M (1979) Incidence and aetiology of infantile spasms from 1960 to 1976: a population study in Finland. Dev Med Child Neurol 21:333–343CrossRefPubMed
2.
go back to reference Sidenvall R, Eeg-Olofsson O (1995) Epidemiology of infantile spasms in Sweden. Epilepsia 36:572–574CrossRefPubMed Sidenvall R, Eeg-Olofsson O (1995) Epidemiology of infantile spasms in Sweden. Epilepsia 36:572–574CrossRefPubMed
3.
go back to reference Rantala H, Putkonen T (1999) Occurrence, outcome, and prognostic factors of infantile spasms and Lennox-Gastaut syndrome. Epilepsia 40:286–289CrossRefPubMed Rantala H, Putkonen T (1999) Occurrence, outcome, and prognostic factors of infantile spasms and Lennox-Gastaut syndrome. Epilepsia 40:286–289CrossRefPubMed
5.
go back to reference Chiron C, Dumas C, Jambaqué I et al (1997) Randomized trial comparing vigabatrin and hydrocortisone in infantile spasms due to tuberous sclerosis. Epilepsy Res 26:389–395CrossRefPubMed Chiron C, Dumas C, Jambaqué I et al (1997) Randomized trial comparing vigabatrin and hydrocortisone in infantile spasms due to tuberous sclerosis. Epilepsy Res 26:389–395CrossRefPubMed
6.
go back to reference Jones K, Go C, Boyd J et al (2015) Vigabatrin as first-line treatment for infantile spasms not related to tuberous sclerosis complex. Pediatr Neurol 53:141–145CrossRefPubMed Jones K, Go C, Boyd J et al (2015) Vigabatrin as first-line treatment for infantile spasms not related to tuberous sclerosis complex. Pediatr Neurol 53:141–145CrossRefPubMed
7.
go back to reference Eke T, Talbot JF, Lawden MC (1997) Severe persistent visual field constriction associated with vigabatrin. Br Med J 314:180–181CrossRef Eke T, Talbot JF, Lawden MC (1997) Severe persistent visual field constriction associated with vigabatrin. Br Med J 314:180–181CrossRef
9.
go back to reference Harding GF, Wild JM, Robertson KA et al (2000) Separating the retinal electrophysiologic effects of vigabatrin: treatment versus field loss. Am J Ophthalmol 55:347–352 Harding GF, Wild JM, Robertson KA et al (2000) Separating the retinal electrophysiologic effects of vigabatrin: treatment versus field loss. Am J Ophthalmol 55:347–352
10.
go back to reference Good WV (2011) Measuring field loss in children administered vigabatrin: a problem in search of a solution. J AAPOS 15:411–412CrossRefPubMed Good WV (2011) Measuring field loss in children administered vigabatrin: a problem in search of a solution. J AAPOS 15:411–412CrossRefPubMed
11.
go back to reference McCulloch DL, Marmor MF, Brigell MG et al (2015) ISCEV Standard for full-field clinical electroretinography (2015 update). Doc Ophthalmol 130:1–12CrossRef McCulloch DL, Marmor MF, Brigell MG et al (2015) ISCEV Standard for full-field clinical electroretinography (2015 update). Doc Ophthalmol 130:1–12CrossRef
12.
go back to reference Westall CA, Wright T, Cortese F et al (2014) Vigabatrin retinal toxicity in children with infantile spasms: an observational cohort study. Neurology 83:2262–2268CrossRefPubMedPubMedCentral Westall CA, Wright T, Cortese F et al (2014) Vigabatrin retinal toxicity in children with infantile spasms: an observational cohort study. Neurology 83:2262–2268CrossRefPubMedPubMedCentral
13.
go back to reference Sun L (2010) Early childhood general anaesthesia exposure and neurocognitive development. BJA Br J Anaesth 105:i61–i68CrossRefPubMed Sun L (2010) Early childhood general anaesthesia exposure and neurocognitive development. BJA Br J Anaesth 105:i61–i68CrossRefPubMed
14.
go back to reference Zhang H, Du L, Du Z et al (2015) Association between childhood exposure to single general anesthesia and neurodevelopment: a systematic review and meta-analysis of cohort study. J Anesth 29:749–757CrossRefPubMed Zhang H, Du L, Du Z et al (2015) Association between childhood exposure to single general anesthesia and neurodevelopment: a systematic review and meta-analysis of cohort study. J Anesth 29:749–757CrossRefPubMed
15.
go back to reference Davidson AJ, Becke K, De Graaff J et al (2015) Anesthesia and the developing brain: a way forward for clinical research. Paediatr Anaesth 25:447–452CrossRefPubMed Davidson AJ, Becke K, De Graaff J et al (2015) Anesthesia and the developing brain: a way forward for clinical research. Paediatr Anaesth 25:447–452CrossRefPubMed
16.
go back to reference Kato K, Kondo M, Sugimoto M et al (2015) Effect of pupil size on flicker ERGs recorded with RETeval system: new mydriasis-free full-field ERG system. Investig Ophthalmol Vis Sci 56:3684–3690CrossRef Kato K, Kondo M, Sugimoto M et al (2015) Effect of pupil size on flicker ERGs recorded with RETeval system: new mydriasis-free full-field ERG system. Investig Ophthalmol Vis Sci 56:3684–3690CrossRef
17.
go back to reference Grace SF, Lam BL, Feuer WJ et al (2017) Nonsedated handheld electroretinogram as a screening test of retinal dysfunction in pediatric patients with nystagmus. J AAPOS 21:384–388CrossRefPubMed Grace SF, Lam BL, Feuer WJ et al (2017) Nonsedated handheld electroretinogram as a screening test of retinal dysfunction in pediatric patients with nystagmus. J AAPOS 21:384–388CrossRefPubMed
18.
go back to reference Al-Otaibi H, Al-Otaibi MD, Khandekar R et al (2017) Validity, usefulness and cost of RET eval system for diabetic retinopathy screening. Transl Vis Sci Technol 6:3CrossRefPubMedPubMedCentral Al-Otaibi H, Al-Otaibi MD, Khandekar R et al (2017) Validity, usefulness and cost of RET eval system for diabetic retinopathy screening. Transl Vis Sci Technol 6:3CrossRefPubMedPubMedCentral
19.
go back to reference Miura G, Nakamura Y, Sato E, Yamamoto S (2016) Effects of cataracts on flicker electroretinograms recorded with RETevalTM system: new mydriasis-free ERG device. BMC Ophthalmol 16:22CrossRefPubMedPubMedCentral Miura G, Nakamura Y, Sato E, Yamamoto S (2016) Effects of cataracts on flicker electroretinograms recorded with RETevalTM system: new mydriasis-free ERG device. BMC Ophthalmol 16:22CrossRefPubMedPubMedCentral
20.
go back to reference Asakawa K, Amino K, Iwase M et al (2017) New mydriasis-free electroretinogram recorded with skin electrodes in healthy subjects. Biomed Res Int 2017:1–7CrossRef Asakawa K, Amino K, Iwase M et al (2017) New mydriasis-free electroretinogram recorded with skin electrodes in healthy subjects. Biomed Res Int 2017:1–7CrossRef
21.
go back to reference Liu H, Ji X, Dhaliwal S et al (2018) Evaluation of light- and dark-adapted ERGs using a mydriasis-free, portable system: clinical classifications and normative data. Doc Ophthalmol 137:169–181CrossRefPubMed Liu H, Ji X, Dhaliwal S et al (2018) Evaluation of light- and dark-adapted ERGs using a mydriasis-free, portable system: clinical classifications and normative data. Doc Ophthalmol 137:169–181CrossRefPubMed
22.
go back to reference Davis CQ, Kraszewska O, Manning C (2017) Constant luminance (cd·s/m2) versus constant retinal illuminance (Td·s) stimulation in flicker ERGs. Doc Ophthalmol 134:75–87CrossRefPubMedPubMedCentral Davis CQ, Kraszewska O, Manning C (2017) Constant luminance (cd·s/m2) versus constant retinal illuminance (Td·s) stimulation in flicker ERGs. Doc Ophthalmol 134:75–87CrossRefPubMedPubMedCentral
23.
go back to reference Nakamura N, Fujinami K, Mizuno Y et al (2016) Evaluation of cone function by a handheld non-mydriatic flicker electroretinogram device. Clin Ophthalmol 10:1175–1185CrossRefPubMedPubMedCentral Nakamura N, Fujinami K, Mizuno Y et al (2016) Evaluation of cone function by a handheld non-mydriatic flicker electroretinogram device. Clin Ophthalmol 10:1175–1185CrossRefPubMedPubMedCentral
Metadata
Title
Hand-held, dilation-free, electroretinography in children under 3 years of age treated with vigabatrin
Authors
Xiang Ji
Michelle McFarlane
Henry Liu
Annie Dupuis
Carol A. Westall
Publication date
01-06-2019
Publisher
Springer Berlin Heidelberg
Published in
Documenta Ophthalmologica / Issue 3/2019
Print ISSN: 0012-4486
Electronic ISSN: 1573-2622
DOI
https://doi.org/10.1007/s10633-019-09684-9

Other articles of this Issue 3/2019

Documenta Ophthalmologica 3/2019 Go to the issue