Published in: BMC Public Health 1/2019

Open Access 01-12-2019 | Research article

Validation of automatic wear-time detection algorithms in a free-living setting of wrist-worn and hip-worn ActiGraph GT3X+

Authors: Raphael Knaier, Christoph Höchsmann, Denis Infanger, Timo Hinrichs, Arno Schmidt-Trucksäss

Published in: BMC Public Health | Issue 1/2019

Login to get access

Abstract

Background

Wrist-worn accelerometers are increasingly used in epidemiological studies to record physical activity. The accelerometer data are usually only analyzed if the convention for compliant wear time is met (i.e. ≥ 10 h per day) but the algorithms to detect wear time have been developed based on data from hip-worn devices only and have not been tested in a free-living setting. The aim of this study was to validate the automatic wear time detection algorithms of one of the most frequently used devices in a free-living setting.

Methods

Sixty-eight adults wore one ActiGraph GT3X+ accelerometer on the wrist and one on the hip and additionally recorded wear times for each device separately in a diary. Monitoring phase was during three consecutive days in a free-living setting. Wear time was computed by the algorithms of Troiano and Choi and compared to the diary recordings.

Results

Mean wear time was over 1420 min per day for both devices on all days. Lin’s concordance correlation coefficient for the wrist-worn wear time was 0.73 (0.60; 0.82) when comparing the diary with Troiano and 0.78 (0.67; 0.86) when comparing the diary with Choi. For hip-worn devices the respective values were 0.23 (0.13; 0.33) for Troiano and 0.92 (0.88; 0.95) for Choi. Mean and standard deviation values for absolute percentage errors for wrist-worn devices were − 1.3 ± 8.1% in Troiano and 0.9 ± 7.7% in Choi. The respective values for hip-worn devices were − 17.5 ± 10% in Troiano and − 0.8 ± 4.6% in Choi.

Conclusions

Hip worn devices may be preferred due to their higher accuracy in physical activity measurement. Automatic wear-time detection can show high errors in individuals, but on a group level, type I, type II, and total errors are generally low when the Choi algorithm is used. In a real-life setting and participants with a high compliance, the algorithm by Choi is sufficient to distinguish wear time from non-wear time on a group level.
Literature
1.
go back to reference Lipert A, Jegier A. Comparison of different physical activity measurement methods in adults aged 45 to 64 years under free-living conditions. Clin J Sport Med 2016;0:1–9. Lipert A, Jegier A. Comparison of different physical activity measurement methods in adults aged 45 to 64 years under free-living conditions. Clin J Sport Med 2016;0:1–9.
2.
go back to reference Freedson PS, John D. Comment on “Estimating Activity and Sedentary Behavior from an Accelerometer on the Hip and Wrist”. Med Sci Sports Exerc. 2013;45(5):962–3.CrossRef Freedson PS, John D. Comment on “Estimating Activity and Sedentary Behavior from an Accelerometer on the Hip and Wrist”. Med Sci Sports Exerc. 2013;45(5):962–3.CrossRef
3.
go back to reference Kerr J, Marinac CR, Ellis K, Godbole S, Hipp A, Glanz K, et al. Comparison of Accelerometry methods for estimating physical activity. Med Sci Sports Exerc. 2017;49(3):617–24.CrossRef Kerr J, Marinac CR, Ellis K, Godbole S, Hipp A, Glanz K, et al. Comparison of Accelerometry methods for estimating physical activity. Med Sci Sports Exerc. 2017;49(3):617–24.CrossRef
4.
go back to reference Doherty A, Jackson D, Hammerla N, Plötz T, Olivier P, Granat MH, et al. Large scale population assessment of physical activity using wrist worn accelerometers: the UK biobank study. Buchowski M, editor. PLoS One 2017;12(2):e0169649. Doherty A, Jackson D, Hammerla N, Plötz T, Olivier P, Granat MH, et al. Large scale population assessment of physical activity using wrist worn accelerometers: the UK biobank study. Buchowski M, editor. PLoS One 2017;12(2):e0169649.
5.
go back to reference White T, Westgate K, Wareham NJ, Brage S. Estimation of physical activity energy expenditure during free-living from wrist Accelerometry in UK adults. Song H, editor. PLoS One 2016;11(12):e0167472. White T, Westgate K, Wareham NJ, Brage S. Estimation of physical activity energy expenditure during free-living from wrist Accelerometry in UK adults. Song H, editor. PLoS One 2016;11(12):e0167472.
6.
go back to reference Migueles JH, Cadenas-Sanchez C, Ekelund U, Delisle Nyström C, Mora-Gonzalez J, Löf M, et al. Accelerometer data collection and processing criteria to assess physical activity and other outcomes: a systematic review and practical considerations. Sports Med Auckl NZ. 2017;16. Migueles JH, Cadenas-Sanchez C, Ekelund U, Delisle Nyström C, Mora-Gonzalez J, Löf M, et al. Accelerometer data collection and processing criteria to assess physical activity and other outcomes: a systematic review and practical considerations. Sports Med Auckl NZ. 2017;16.
7.
go back to reference Lee I-M, Shiroma EJ, Evenson KR, Kamada M, LaCroix AZ, Buring JE. Accelerometer-measured physical activity and sedentary behavior in relation to all-cause mortality: the Women’s health study. Circulation. 2017 Nov 6;CIRCULATIONAHA.117.031300. Lee I-M, Shiroma EJ, Evenson KR, Kamada M, LaCroix AZ, Buring JE. Accelerometer-measured physical activity and sedentary behavior in relation to all-cause mortality: the Women’s health study. Circulation. 2017 Nov 6;CIRCULATIONAHA.117.031300.
8.
go back to reference Wijndaele K, Westgate K, Stephens SK, Blair SN, Bull FC, Chastin SFM, et al. Utilization and harmonization of adult Accelerometry data: review and expert consensus. Med Sci Sports Exerc. 2015;47(10):2129–39.CrossRef Wijndaele K, Westgate K, Stephens SK, Blair SN, Bull FC, Chastin SFM, et al. Utilization and harmonization of adult Accelerometry data: review and expert consensus. Med Sci Sports Exerc. 2015;47(10):2129–39.CrossRef
9.
go back to reference Choi L, Liu Z, Matthews CE, Buchowski MS. Validation of accelerometer wear and nonwear time classification algorithm. Med Sci Sports Exerc. 2011;43(2):357–64.CrossRef Choi L, Liu Z, Matthews CE, Buchowski MS. Validation of accelerometer wear and nonwear time classification algorithm. Med Sci Sports Exerc. 2011;43(2):357–64.CrossRef
10.
go back to reference Mattocks C, Ness A, Leary S, Tilling K, Blair SN, Shield J, et al. Use of accelerometers in a large field-based study of children: protocols, design issues, and effects on precision. J Phys Act Health. 2008;5(Suppl 1):S98–111.CrossRef Mattocks C, Ness A, Leary S, Tilling K, Blair SN, Shield J, et al. Use of accelerometers in a large field-based study of children: protocols, design issues, and effects on precision. J Phys Act Health. 2008;5(Suppl 1):S98–111.CrossRef
11.
go back to reference Watson PF, Petrie A. Method agreement analysis: a review of correct methodology. Theriogenology. 2010;73(9):1167–79.CrossRef Watson PF, Petrie A. Method agreement analysis: a review of correct methodology. Theriogenology. 2010;73(9):1167–79.CrossRef
12.
go back to reference Zhou S-M, Hill RA, Morgan K, Stratton G, Gravenor MB, Bijlsma G, et al. Classification of accelerometer wear and non-wear events in seconds for monitoring free-living physical activity. BMJ Open. 2015;5(5):e007447.CrossRef Zhou S-M, Hill RA, Morgan K, Stratton G, Gravenor MB, Bijlsma G, et al. Classification of accelerometer wear and non-wear events in seconds for monitoring free-living physical activity. BMJ Open. 2015;5(5):e007447.CrossRef
13.
go back to reference Choi L, Ward SC, Schnelle JF, Buchowski MS. Assessment of Wear/nonwear time classification algorithms for Triaxial accelerometer. Med Sci Sports Exerc. 2012;44(10):2009–16.CrossRef Choi L, Ward SC, Schnelle JF, Buchowski MS. Assessment of Wear/nonwear time classification algorithms for Triaxial accelerometer. Med Sci Sports Exerc. 2012;44(10):2009–16.CrossRef
Metadata
Title
Validation of automatic wear-time detection algorithms in a free-living setting of wrist-worn and hip-worn ActiGraph GT3X+
Authors
Raphael Knaier
Christoph Höchsmann
Denis Infanger
Timo Hinrichs
Arno Schmidt-Trucksäss
Publication date
01-12-2019
Publisher
BioMed Central
Published in
BMC Public Health / Issue 1/2019
Electronic ISSN: 1471-2458
DOI
https://doi.org/10.1186/s12889-019-6568-9

Other articles of this Issue 1/2019

BMC Public Health 1/2019 Go to the issue