Skip to main content
Top
Published in: European Journal of Pediatrics 8/2023

Open Access 01-06-2023 | RESEARCH

Validation of an accelerometer system for measuring physical activity and sedentary behavior in healthy children and adolescents

Authors: Camilla Milther, Lærke Winther, Michelle Stahlhut, Derek John Curtis, Mette Aadahl, Morten Tange Kristensen, Jette Led Sørensen, Christian Have Dall

Published in: European Journal of Pediatrics | Issue 8/2023

Login to get access

Abstract

The study aims to assess the concurrent validity of the SENS motion® accelerometer system for device-based measurement of physical activity and sedentary behavior in healthy children and adolescents. Thirty-six healthy children and adolescents (mean ± standard deviation (SD) age, 10.2 ± 2.3 years) were fitted with three SENS sensors while performing standardized activities including walking, fast walking, sitting/lying, and arm movements. Data from the sensors were compared with video observations (reference criteria). The agreement between SENS motion® and observation was analyzed using Student’s t-test and illustrated in Bland–Altman plots. The concurrent validity was further evaluated using intraclass correlation coefficient (ICC) and was expressed as standard error of measurement (SEM) and minimal detectable change (MDC). Strong agreement was found between SENS and observation for walking time, sedentary time, and lying time. In contrast, moderate agreement was observed for number of steps, sitting time, and time with and without arm movement. ICC2.1 values were overall moderate to excellent (0.5–0.94), with correspondingly low SEM% for walking time, sedentary time, lying time, and time with arm movement (2–9%). An acceptable SEM% level was reached for both steps and sitting time (11% and 12%). For fast walking time, the results showed a weak agreement between the measurement methods, and the ICC value was poor.
Conclusion: SENS motion® seems valid for detecting physical activity and sedentary behavior in healthy children and adolescents with strong agreement and moderate to excellent ICC values. Furthermore, the explorative results on arm movements seem promising.
What is Known:
• Inactivity and sedentary behavior follow an increasing trend among children and adolescents.
• SENS motion® seems to be valid for measuring physical activity and sedentary behavior in adults and elderly patients.
What is New:
• SENS motion® seems valid with strong agreement between video observations and SENS measurement, and ICC values are moderate to excellent when measuring physical activity and sedentary behavior in healthy children and adolescents.
• SENS motion® seems promising for detection of arm movements.
Literature
1.
go back to reference Guthold R, Stevens GA, Riley LM, Bull FC (2018) Worldwide trends in insufficient physical activity from 2001 to 2016: a pooled analysis of 358 population-based surveys with 1·9 million participants. Lancet Glob Heal 6(10):e1077–e1086CrossRef Guthold R, Stevens GA, Riley LM, Bull FC (2018) Worldwide trends in insufficient physical activity from 2001 to 2016: a pooled analysis of 358 population-based surveys with 1·9 million participants. Lancet Glob Heal 6(10):e1077–e1086CrossRef
2.
go back to reference Guthold R, Stevens GA, Riley LM, Bull FC (2020) Global trends in insufficient physical activity among adolescents: a pooled analysis of 298 population-based surveys with 1·6 million participants. Lancet Child Adolesc Heal [Internet] 4(1):23–35. Available from: https://doi.org/10.1016/S2352-4642(19)30323-2 Guthold R, Stevens GA, Riley LM, Bull FC (2020) Global trends in insufficient physical activity among adolescents: a pooled analysis of 298 population-based surveys with 1·6 million participants. Lancet Child Adolesc Heal [Internet] 4(1):23–35. Available from: https://​doi.​org/​10.​1016/​S2352-4642(19)30323-2
3.
go back to reference Steene-Johannessen J, Hansen BH, Dalene KE, Kolle E, Northstone K, Møller NC et al (2020) Variations in accelerometry measured physical activity and sedentary time across Europe — harmonized analyses of 47,497 children and adolescents. Int J Behav Nutr Phys Act 17(1):38CrossRefPubMedPubMedCentral Steene-Johannessen J, Hansen BH, Dalene KE, Kolle E, Northstone K, Møller NC et al (2020) Variations in accelerometry measured physical activity and sedentary time across Europe — harmonized analyses of 47,497 children and adolescents. Int J Behav Nutr Phys Act 17(1):38CrossRefPubMedPubMedCentral
4.
go back to reference Cooper AR, Goodman A, Page AS, Sherar LB, Esliger DW, van Sluijs EMF et al (2015) Objectively measured physical activity and sedentary time in youth: the International Children’s Accelerometry Database (ICAD). Int J Behav Nutr Phys Act 12:113CrossRefPubMedPubMedCentral Cooper AR, Goodman A, Page AS, Sherar LB, Esliger DW, van Sluijs EMF et al (2015) Objectively measured physical activity and sedentary time in youth: the International Children’s Accelerometry Database (ICAD). Int J Behav Nutr Phys Act 12:113CrossRefPubMedPubMedCentral
5.
go back to reference Westerterp KR (2014) Reliable assessment of physical activity in disease: an update on activity monitors. Curr Opin Clin Nutr Metab Care 17(5):401–406CrossRefPubMed Westerterp KR (2014) Reliable assessment of physical activity in disease: an update on activity monitors. Curr Opin Clin Nutr Metab Care 17(5):401–406CrossRefPubMed
6.
go back to reference Arvidsson D, Fridolfsson J, Börjesson M (2019) Measurement of physical activity in clinical practice using accelerometers. J Intern Med 286(2):137–153PubMed Arvidsson D, Fridolfsson J, Börjesson M (2019) Measurement of physical activity in clinical practice using accelerometers. J Intern Med 286(2):137–153PubMed
7.
go back to reference Giurgiu M, Timm I, Becker M, Schmidt S, Wunsch K, Nissen R et al (2022) Quality evaluation of free-living validation studies for the assessment of 24-hour physical behavior in adults via wearables: systematic review [Internet]. Vol. 10, JMIR mHealth and uHealth. [cited 2023 Feb 23]. Available from: https://mhealth.jmir.org/2022/6/e36377 Giurgiu M, Timm I, Becker M, Schmidt S, Wunsch K, Nissen R et al (2022) Quality evaluation of free-living validation studies for the assessment of 24-hour physical behavior in adults via wearables: systematic review [Internet]. Vol. 10, JMIR mHealth and uHealth. [cited 2023 Feb 23]. Available from: https://​mhealth.​jmir.​org/​2022/​6/​e36377
8.
go back to reference Pedersen BS, Kristensen MT, Josefsen CO, Lykkegaard KL, Jønsson LR, Pedersen MM (2022) Validation of two activity monitors in slow and fast walking hospitalized patients. Rehabil Res Pract 2022:9230081PubMedPubMedCentral Pedersen BS, Kristensen MT, Josefsen CO, Lykkegaard KL, Jønsson LR, Pedersen MM (2022) Validation of two activity monitors in slow and fast walking hospitalized patients. Rehabil Res Pract 2022:9230081PubMedPubMedCentral
9.
go back to reference Bartholdy C, Gudbergsen H, Bliddal H, Kjærgaard M, Lykkegaard KL, Henriksen M (2018) Reliability and construct validity of the SENS motion® activity measurement system as a tool to detect sedentary behaviour in patients with knee osteoarthritis. Arthritis 2018:6596278CrossRefPubMedPubMedCentral Bartholdy C, Gudbergsen H, Bliddal H, Kjærgaard M, Lykkegaard KL, Henriksen M (2018) Reliability and construct validity of the SENS motion® activity measurement system as a tool to detect sedentary behaviour in patients with knee osteoarthritis. Arthritis 2018:6596278CrossRefPubMedPubMedCentral
10.
go back to reference Bailey RC, Olson J, Pepper SL, Porszasz J, Barstow TJ, Cooper DM (1995) The level and tempo of children’s physical activities: an observational study. Med Sci Sports Exerc 27(7):1033–1041CrossRefPubMed Bailey RC, Olson J, Pepper SL, Porszasz J, Barstow TJ, Cooper DM (1995) The level and tempo of children’s physical activities: an observational study. Med Sci Sports Exerc 27(7):1033–1041CrossRefPubMed
11.
go back to reference Welk GJ, Corbin CB, Dale D (2000) Measurement issues in the assessment of physical activity in children. Res Q Exerc Sport 71(Suppl 2):59–73CrossRefPubMed Welk GJ, Corbin CB, Dale D (2000) Measurement issues in the assessment of physical activity in children. Res Q Exerc Sport 71(Suppl 2):59–73CrossRefPubMed
12.
go back to reference Flameling LJ, Mesman J (2022) Using video observation in the family context: the association between camera-related behaviors and parental sensitivity. Infancy 27(1):115–134CrossRefPubMed Flameling LJ, Mesman J (2022) Using video observation in the family context: the association between camera-related behaviors and parental sensitivity. Infancy 27(1):115–134CrossRefPubMed
13.
go back to reference Lindemann U, Zijlstra W, Aminian K, Chastin SFM, de Bruin ED, Helbostad JL et al (2014) Recommendations for standardizing validation procedures assessing physical activity of older persons by monitoring body postures and movements. Sensors (Basel) 14(1):1267–1277CrossRefPubMed Lindemann U, Zijlstra W, Aminian K, Chastin SFM, de Bruin ED, Helbostad JL et al (2014) Recommendations for standardizing validation procedures assessing physical activity of older persons by monitoring body postures and movements. Sensors (Basel) 14(1):1267–1277CrossRefPubMed
15.
go back to reference Stewart T, Narayanan A, Hedayatrad L, Neville J, Mackay L, Duncan S (2018) A dual-accelerometer system for classifying physical activity in children and adults. Med Sci Sports Exerc 50(12):2595–2602CrossRefPubMed Stewart T, Narayanan A, Hedayatrad L, Neville J, Mackay L, Duncan S (2018) A dual-accelerometer system for classifying physical activity in children and adults. Med Sci Sports Exerc 50(12):2595–2602CrossRefPubMed
16.
go back to reference McAloon MT, Hutchins S, Twiste M, Jones R, Forchtner S (2014) Validation of the activPAL activity monitor in children with hemiplegic gait patterns resultant from cerebral palsy. Prosthet Orthot Int 38(5):393–399CrossRefPubMed McAloon MT, Hutchins S, Twiste M, Jones R, Forchtner S (2014) Validation of the activPAL activity monitor in children with hemiplegic gait patterns resultant from cerebral palsy. Prosthet Orthot Int 38(5):393–399CrossRefPubMed
17.
go back to reference Lynch BA, Kaufman TK, Rajjo TI, Mohammed K, Kumar S, Murad MH et al (2019) Accuracy of accelerometers for measuring physical activity and levels of sedentary behavior in children: a systematic review. J Prim Care Community Health 10:2150132719874252CrossRefPubMed Lynch BA, Kaufman TK, Rajjo TI, Mohammed K, Kumar S, Murad MH et al (2019) Accuracy of accelerometers for measuring physical activity and levels of sedentary behavior in children: a systematic review. J Prim Care Community Health 10:2150132719874252CrossRefPubMed
18.
go back to reference Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet (London, England) 1(8476):307–310CrossRefPubMed Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet (London, England) 1(8476):307–310CrossRefPubMed
19.
go back to reference Bland JM, Altman DG (1999) Measuring agreement in method comparison studies. Stat Methods Med Res 8(2):135–160CrossRefPubMed Bland JM, Altman DG (1999) Measuring agreement in method comparison studies. Stat Methods Med Res 8(2):135–160CrossRefPubMed
20.
go back to reference Koo TK, Li MY (2016) A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med 15(2):155–163CrossRefPubMedPubMedCentral Koo TK, Li MY (2016) A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med 15(2):155–163CrossRefPubMedPubMedCentral
21.
go back to reference Beckerman H, Roebroeck ME, Lankhorst GJ, Becher JG, Bezemer PD, Verbeek ALM (2001) Smallest real difference, a link between reproducibility and responsiveness. Qual Life Res 10(7):571–578CrossRefPubMed Beckerman H, Roebroeck ME, Lankhorst GJ, Becher JG, Bezemer PD, Verbeek ALM (2001) Smallest real difference, a link between reproducibility and responsiveness. Qual Life Res 10(7):571–578CrossRefPubMed
22.
go back to reference Welk GJ, Bai Y, Lee JM, Godino JOB, Saint-Maurice PF, Carr L (2019) Standardizing analytic methods and reporting in activity monitor validation studies. Med Sci Sports Exerc 51(8):1767–1780CrossRefPubMedPubMedCentral Welk GJ, Bai Y, Lee JM, Godino JOB, Saint-Maurice PF, Carr L (2019) Standardizing analytic methods and reporting in activity monitor validation studies. Med Sci Sports Exerc 51(8):1767–1780CrossRefPubMedPubMedCentral
23.
go back to reference Aminian S, Hinckson EA (2012) Examining the validity of the ActivPAL monitor in measuring posture and ambulatory movement in children. Int J Behav Nutr Phys Act 9:119CrossRefPubMedPubMedCentral Aminian S, Hinckson EA (2012) Examining the validity of the ActivPAL monitor in measuring posture and ambulatory movement in children. Int J Behav Nutr Phys Act 9:119CrossRefPubMedPubMedCentral
25.
go back to reference Rispens SM, Cox LGE, Ejupi A, Delbaere K, Annegarn J, Bonomi AG (2021) Validation of walking speed estimation from trunk mounted accelerometers for a range of walking speeds. Sensors (Basel) 21(5) Rispens SM, Cox LGE, Ejupi A, Delbaere K, Annegarn J, Bonomi AG (2021) Validation of walking speed estimation from trunk mounted accelerometers for a range of walking speeds. Sensors (Basel) 21(5)
26.
go back to reference Rosenkranz RR, Rosenkranz SK, Weber C (2011) Validity of the Actical accelerometer step-count function in children. Pediatr Exerc Sci 23(3):355–365CrossRefPubMed Rosenkranz RR, Rosenkranz SK, Weber C (2011) Validity of the Actical accelerometer step-count function in children. Pediatr Exerc Sci 23(3):355–365CrossRefPubMed
27.
go back to reference Lubans DR, Hesketh K, Cliff DP, Barnett LM, Salmon J, Dollman J et al (2011) A systematic review of the validity and reliability of sedentary behaviour measures used with children and adolescents. Obes Rev an Off J Int Assoc Study Obes 12(10):781–799CrossRef Lubans DR, Hesketh K, Cliff DP, Barnett LM, Salmon J, Dollman J et al (2011) A systematic review of the validity and reliability of sedentary behaviour measures used with children and adolescents. Obes Rev an Off J Int Assoc Study Obes 12(10):781–799CrossRef
28.
go back to reference Hollewand AM, Spijkerman AG, Bilo HJG, Kleefstra N, Kamsma Y, van Hateren KJJ (2016) Validity of an accelerometer-based activity monitor system for measuring physical activity in frail older adults. J Aging Phys Act 24(4):555–558CrossRefPubMed Hollewand AM, Spijkerman AG, Bilo HJG, Kleefstra N, Kamsma Y, van Hateren KJJ (2016) Validity of an accelerometer-based activity monitor system for measuring physical activity in frail older adults. J Aging Phys Act 24(4):555–558CrossRefPubMed
29.
go back to reference Ridley K, Ridgers ND, Salmon J (2016) Criterion validity of the activPAL™ and ActiGraph for assessing children’s sitting and standing time in a school classroom setting. Int J Behav Nutr Phys Act 13:75CrossRefPubMedPubMedCentral Ridley K, Ridgers ND, Salmon J (2016) Criterion validity of the activPAL™ and ActiGraph for assessing children’s sitting and standing time in a school classroom setting. Int J Behav Nutr Phys Act 13:75CrossRefPubMedPubMedCentral
30.
go back to reference Troiano RP, McClain JJ, Brychta RJ, Chen KY (2014) Evolution of accelerometer methods for physical activity research. Br J Sports Med 48(13):1019–1023CrossRefPubMed Troiano RP, McClain JJ, Brychta RJ, Chen KY (2014) Evolution of accelerometer methods for physical activity research. Br J Sports Med 48(13):1019–1023CrossRefPubMed
31.
go back to reference Hislop J, Palmer N, Anand P, Aldin T (2016) Validity of wrist worn accelerometers and comparability between hip and wrist placement sites in estimating physical activity behaviour in preschool children. Physiol Meas 37(10):1701–1714CrossRefPubMed Hislop J, Palmer N, Anand P, Aldin T (2016) Validity of wrist worn accelerometers and comparability between hip and wrist placement sites in estimating physical activity behaviour in preschool children. Physiol Meas 37(10):1701–1714CrossRefPubMed
32.
go back to reference Ekblom O, Nyberg G, Bak EE, Ekelund U, Marcus C (2012) Validity and comparability of a wrist-worn accelerometer in children. J Phys Act Health 9(3):389–393CrossRefPubMed Ekblom O, Nyberg G, Bak EE, Ekelund U, Marcus C (2012) Validity and comparability of a wrist-worn accelerometer in children. J Phys Act Health 9(3):389–393CrossRefPubMed
33.
go back to reference Duncan MJ, Wilson S, Tallis J, Eyre E (2016) Validation of the Phillips et al. GENEActiv accelerometer wrist cut-points in children aged 5–8 years old. Eur J Pediatr 175(12):2019–2021CrossRefPubMed Duncan MJ, Wilson S, Tallis J, Eyre E (2016) Validation of the Phillips et al. GENEActiv accelerometer wrist cut-points in children aged 5–8 years old. Eur J Pediatr 175(12):2019–2021CrossRefPubMed
34.
go back to reference Hao Y, Ma X-K, Zhu Z, Cao Z-B (2021) Validity of wrist-wearable activity devices for estimating physical activity in adolescents: comparative study. JMIR mHealth uHealth 9(1):e18320CrossRefPubMedPubMedCentral Hao Y, Ma X-K, Zhu Z, Cao Z-B (2021) Validity of wrist-wearable activity devices for estimating physical activity in adolescents: comparative study. JMIR mHealth uHealth 9(1):e18320CrossRefPubMedPubMedCentral
35.
go back to reference Zoccolillo L, Morelli D, Cincotti F, Muzzioli L, Gobbetti T, Paolucci S et al (2015) Video-game based therapy performed by children with cerebral palsy: a cross-over randomized controlled trial and a cross-sectional quantitative measure of physical activity. Eur J Phys Rehabil Med 51(6):669–676PubMed Zoccolillo L, Morelli D, Cincotti F, Muzzioli L, Gobbetti T, Paolucci S et al (2015) Video-game based therapy performed by children with cerebral palsy: a cross-over randomized controlled trial and a cross-sectional quantitative measure of physical activity. Eur J Phys Rehabil Med 51(6):669–676PubMed
36.
go back to reference Kaneko M, Yamashita Y, Iramina K (2016) Quantitative evaluation system of soft neurological signs for children with attention deficit hyperactivity disorder. Sensors (Basel) 16(1) Kaneko M, Yamashita Y, Iramina K (2016) Quantitative evaluation system of soft neurological signs for children with attention deficit hyperactivity disorder. Sensors (Basel) 16(1)
37.
go back to reference O’Neil ME, Fragala-Pinkham M, Lennon N, George A, Forman J, Trost SG (2016) Reliability and validity of objective measures of physical activity in youth with cerebral palsy who are ambulatory. Phys Ther 96(1):37–45CrossRefPubMed O’Neil ME, Fragala-Pinkham M, Lennon N, George A, Forman J, Trost SG (2016) Reliability and validity of objective measures of physical activity in youth with cerebral palsy who are ambulatory. Phys Ther 96(1):37–45CrossRefPubMed
38.
go back to reference Strohrmann C, Labruyère R, Gerber CN, van Hedel HJ, Arnrich B, Tröster G (2013) Monitoring motor capacity changes of children during rehabilitation using body-worn sensors. J Neuroeng Rehabil 10:83CrossRefPubMedPubMedCentral Strohrmann C, Labruyère R, Gerber CN, van Hedel HJ, Arnrich B, Tröster G (2013) Monitoring motor capacity changes of children during rehabilitation using body-worn sensors. J Neuroeng Rehabil 10:83CrossRefPubMedPubMedCentral
39.
go back to reference Rowlands AV, Eston RG (2007) The measurement and interpretation of children’s physical activity. J Sports Sci Med 6(3):270–276PubMedPubMedCentral Rowlands AV, Eston RG (2007) The measurement and interpretation of children’s physical activity. J Sports Sci Med 6(3):270–276PubMedPubMedCentral
40.
go back to reference Phillips SM, Summerbell C, Hobbs M, Hesketh KR, Saxena S, Muir C et al (2021) A systematic review of the validity, reliability, and feasibility of measurement tools used to assess the physical activity and sedentary behaviour of pre-school aged children. Int J Behav Nutr Phys Act 18(1):141CrossRefPubMedPubMedCentral Phillips SM, Summerbell C, Hobbs M, Hesketh KR, Saxena S, Muir C et al (2021) A systematic review of the validity, reliability, and feasibility of measurement tools used to assess the physical activity and sedentary behaviour of pre-school aged children. Int J Behav Nutr Phys Act 18(1):141CrossRefPubMedPubMedCentral
41.
go back to reference Mokkink LB, Prinsen CA, Patrick DL, Alonso J, Bouter LM, Terwee CB (2005) COSMIN Study Design checklist for patient-reported outcome measurement instruments. [cited 2023 Mar 2]; Available from: www.cosmin.nl Mokkink LB, Prinsen CA, Patrick DL, Alonso J, Bouter LM, Terwee CB (2005) COSMIN Study Design checklist for patient-reported outcome measurement instruments. [cited 2023 Mar 2]; Available from: www.​cosmin.​nl
Metadata
Title
Validation of an accelerometer system for measuring physical activity and sedentary behavior in healthy children and adolescents
Authors
Camilla Milther
Lærke Winther
Michelle Stahlhut
Derek John Curtis
Mette Aadahl
Morten Tange Kristensen
Jette Led Sørensen
Christian Have Dall
Publication date
01-06-2023
Publisher
Springer Berlin Heidelberg
Published in
European Journal of Pediatrics / Issue 8/2023
Print ISSN: 0340-6199
Electronic ISSN: 1432-1076
DOI
https://doi.org/10.1007/s00431-023-05014-z

Other articles of this Issue 8/2023

European Journal of Pediatrics 8/2023 Go to the issue