Skip to main content
Top
Published in: Forensic Science, Medicine and Pathology 1/2017

01-03-2017 | Original Article

Validation of alternate light sources for detection of bruises in non-embalmed and embalmed cadavers

Authors: Kelly Olds, Roger W. Byard, Calle Winskog, Neil E. I. Langlois

Published in: Forensic Science, Medicine and Pathology | Issue 1/2017

Login to get access

Abstract

Bruising is frequently documented in cases of violence for use as forensic evidence. However, bruises can be overlooked if they are not visible to the naked eye. Alternate light sources such as ultraviolet, narrow band, and infrared have been used in an attempt to reveal the presence of bruising that is not otherwise apparent. However, there is a significant gap in knowledge surrounding this technique as it has not been validated against histology to confirm that bruising is genuinely being enhanced. A recent study evaluated the ability of alternate light sources to enhance visibility of bruises using a pigskin model. However, histological confirmation of bruising in humans using these light sources has not yet been performed. In this study, embalmed and non-embalmed human cadavers were used. Bodies were surveyed with alternate light sources, and enhanced regions that were unapparent under white light were photographed with the alternate light sources and sampled for histological assessment. Immunohistochemical staining for the red blood cell surface protein glycophorin was used determine if the enhanced area was a bruise (defined by the presence of extravasated erythrocytes). Photographs of areas confirmed to be bruises were analyzed using the program Fiji to measure enhancement, which was defined as an increase in the measured transverse diameter. In the non-embalmed and the embalmed cadavers violet alternate light produced the greatest enhancement of histologically confirmed bruises, followed by blue (both p < 0.0001). Regions that were not confirmed as bruises also enhanced, indicating that light sources may not be specific. This suggests that the use of light sources to enhance the visibility of bruising should be undertaken with caution and further studies are required.
Literature
2.
go back to reference Kaczor K, Pierce MC, Makoroff K, Corey TS. Bruising and physical child abuse. Clin Pediatr Emerg Med. 2006;7:153–60.CrossRef Kaczor K, Pierce MC, Makoroff K, Corey TS. Bruising and physical child abuse. Clin Pediatr Emerg Med. 2006;7:153–60.CrossRef
3.
go back to reference McGregor MJ, Du Mont J, Myhr TL. Sexual assault forensic medical examination: is evidence related to successful prosecution? Ann Emerg Med. 2002;39:639–47.CrossRefPubMed McGregor MJ, Du Mont J, Myhr TL. Sexual assault forensic medical examination: is evidence related to successful prosecution? Ann Emerg Med. 2002;39:639–47.CrossRefPubMed
4.
go back to reference Langlois NE. The science behind the quest to determine the age of bruises—a review of the English language literature. Forensic Sci Med Pathol. 2007;3:241–51.CrossRefPubMed Langlois NE. The science behind the quest to determine the age of bruises—a review of the English language literature. Forensic Sci Med Pathol. 2007;3:241–51.CrossRefPubMed
7.
go back to reference Thavarajah D, Vanezis P, Perrett D. Assessment of bruise age on dark-skinned individuals using tristimulus colorimetry. Med Sci Law. 2012;52:6–11.CrossRefPubMed Thavarajah D, Vanezis P, Perrett D. Assessment of bruise age on dark-skinned individuals using tristimulus colorimetry. Med Sci Law. 2012;52:6–11.CrossRefPubMed
8.
go back to reference Dawson TL. Beyond the visible: ultraviolet and infrared radiation. Rev Prog Color Relat Top. 2005;35:31–41.CrossRef Dawson TL. Beyond the visible: ultraviolet and infrared radiation. Rev Prog Color Relat Top. 2005;35:31–41.CrossRef
9.
go back to reference Alfano RR, Yang Y. Stokes shift emission spectroscopy of human tissue and key biomolecules. IEEE J Sel Topics Quantum Electron. 2003;9:148–53.CrossRef Alfano RR, Yang Y. Stokes shift emission spectroscopy of human tissue and key biomolecules. IEEE J Sel Topics Quantum Electron. 2003;9:148–53.CrossRef
10.
go back to reference Golden GS. Use of an alternative light source illumination in bite mark photography. J Forensic Sci. 1994;39:815–23.CrossRefPubMed Golden GS. Use of an alternative light source illumination in bite mark photography. J Forensic Sci. 1994;39:815–23.CrossRefPubMed
11.
go back to reference Holbrook DS, Jackson MC. Use of an alternative light source to assess strangulation victims. J Forensic Nurs. 2013;9:140–5.CrossRefPubMed Holbrook DS, Jackson MC. Use of an alternative light source to assess strangulation victims. J Forensic Nurs. 2013;9:140–5.CrossRefPubMed
12.
go back to reference Wright FD, Golden GS. The use of full spectrum digital photography for evidence collection and preservation in cases involving forensic odontology. Forensic Sci Int. 2010;201:59–67.CrossRefPubMed Wright FD, Golden GS. The use of full spectrum digital photography for evidence collection and preservation in cases involving forensic odontology. Forensic Sci Int. 2010;201:59–67.CrossRefPubMed
13.
go back to reference Lee W, Khoo B. Forensic light sources for detection of biological evidences in crime scene investigation: a review. Malaysian J Forensic Sci. 2010;1:17–28. Lee W, Khoo B. Forensic light sources for detection of biological evidences in crime scene investigation: a review. Malaysian J Forensic Sci. 2010;1:17–28.
14.
go back to reference Olds K, Byard RW, Winskog C, Langlois NEI. Validation of ultraviolet, infrared and narrow band alternate light sources for detection of bruises in a pigskin model. Forensic Sci Med Pathol. 2016; doi:10.1007/s12024-016-9813-x. Olds K, Byard RW, Winskog C, Langlois NEI. Validation of ultraviolet, infrared and narrow band alternate light sources for detection of bruises in a pigskin model. Forensic Sci Med Pathol. 2016; doi:10.​1007/​s12024-016-9813-x.
15.
go back to reference Hsu SM, Raine L, Fanger H. The use of antiavidin antibody and avidin-biotin-peroxidase complex in immunoperoxidase technics. Am J Clin Pathol. 1981;75:816–21.CrossRefPubMed Hsu SM, Raine L, Fanger H. The use of antiavidin antibody and avidin-biotin-peroxidase complex in immunoperoxidase technics. Am J Clin Pathol. 1981;75:816–21.CrossRefPubMed
16.
go back to reference Hughes V, Ellis P, Burt T, Langlois N. The practical application of reflectance spectrophotometry for the demonstration of haemoglobin and its degradation in bruises. J Clin Pathol. 2004;57:355–9.CrossRefPubMedPubMedCentral Hughes V, Ellis P, Burt T, Langlois N. The practical application of reflectance spectrophotometry for the demonstration of haemoglobin and its degradation in bruises. J Clin Pathol. 2004;57:355–9.CrossRefPubMedPubMedCentral
17.
go back to reference Littel KA. National protocol for sexual assault medical forensic examinations. Publication no. NCJ 206554. Washington, DC: United States Department of Justice, Office on Violence Against Women; 2004. Littel KA. National protocol for sexual assault medical forensic examinations. Publication no. NCJ 206554. Washington, DC: United States Department of Justice, Office on Violence Against Women; 2004.
18.
go back to reference Lombardi M, Canter J, Patrick PA, Altman R. Is fluorescence under an alternate light source sufficient to accurately diagnose subclinical bruising? J Forensic Sci. 2015;60:444–9.CrossRefPubMed Lombardi M, Canter J, Patrick PA, Altman R. Is fluorescence under an alternate light source sufficient to accurately diagnose subclinical bruising? J Forensic Sci. 2015;60:444–9.CrossRefPubMed
19.
go back to reference Tabata N, Morita M. Immunohistochemical demonstration of bleeding in decomposed bodies by using anti-glycophorin a monoclonal antibody. Forensic Sci Int. 1997;87:1–8.CrossRefPubMed Tabata N, Morita M. Immunohistochemical demonstration of bleeding in decomposed bodies by using anti-glycophorin a monoclonal antibody. Forensic Sci Int. 1997;87:1–8.CrossRefPubMed
20.
go back to reference Taborelli A, Andreola S, Di Giancamillo A, Gentile G, Domeneghini C, Grandi M. The use of anti-glycophorin a antibody in the detection of red blood cell residues in human soft tissue lesions decomposed in air and water: a pilot study. Med Sci Law. 2011;51:S16–S9.CrossRefPubMed Taborelli A, Andreola S, Di Giancamillo A, Gentile G, Domeneghini C, Grandi M. The use of anti-glycophorin a antibody in the detection of red blood cell residues in human soft tissue lesions decomposed in air and water: a pilot study. Med Sci Law. 2011;51:S16–S9.CrossRefPubMed
21.
go back to reference Sugawara Y, Kadono E, Suzuki A, Yukuta Y, Shibasaki Y, Nishimura N. Hemichrome formation observed in human haemoglobin a under various buffer conditions. Acta Physiol Scand. 2003;179:49–59.CrossRefPubMed Sugawara Y, Kadono E, Suzuki A, Yukuta Y, Shibasaki Y, Nishimura N. Hemichrome formation observed in human haemoglobin a under various buffer conditions. Acta Physiol Scand. 2003;179:49–59.CrossRefPubMed
22.
go back to reference Li TK, Johnson BP. Optically active heme bands of hemoglobin and methemoglobin derivatives. Correlation with absorption and magnetic properties. Biochemistry. 1969;8:3638–43.CrossRefPubMed Li TK, Johnson BP. Optically active heme bands of hemoglobin and methemoglobin derivatives. Correlation with absorption and magnetic properties. Biochemistry. 1969;8:3638–43.CrossRefPubMed
23.
go back to reference Akuwudike AR, Chikezie PC, Chilaka FC. Absorption spectra of normal adults and patients with sickle cell anaemia treated with hydrogen peroxide at two pH values. IJBC. 2013;5:129–35. Akuwudike AR, Chikezie PC, Chilaka FC. Absorption spectra of normal adults and patients with sickle cell anaemia treated with hydrogen peroxide at two pH values. IJBC. 2013;5:129–35.
24.
25.
go back to reference Hughes VK, Ellis PS, Langlois NEI. Alternative light source (polilight®) illumination with digital image analysis does not assist in determining the age of bruises. Forensic Sci Int. 2006;158:104–7.CrossRefPubMed Hughes VK, Ellis PS, Langlois NEI. Alternative light source (polilight®) illumination with digital image analysis does not assist in determining the age of bruises. Forensic Sci Int. 2006;158:104–7.CrossRefPubMed
Metadata
Title
Validation of alternate light sources for detection of bruises in non-embalmed and embalmed cadavers
Authors
Kelly Olds
Roger W. Byard
Calle Winskog
Neil E. I. Langlois
Publication date
01-03-2017
Publisher
Springer US
Published in
Forensic Science, Medicine and Pathology / Issue 1/2017
Print ISSN: 1547-769X
Electronic ISSN: 1556-2891
DOI
https://doi.org/10.1007/s12024-016-9822-9

Other articles of this Issue 1/2017

Forensic Science, Medicine and Pathology 1/2017 Go to the issue

Images in Forensics

Purulent pericarditis