Abstract

Purpose

To evaluate the effect of a novel valveless trocar system (VTS) on perioperative outcomes in patients undergoing robotic-assisted laparoscopic prostatectomy (RALP).

Methods

A single-institution retrospective review was performed of 792 patients undergoing RALP. Preoperative patient variables, tumor characteristics, and perioperative variables were collected and analyzed. The first 150 patients were excluded from analysis to account for the learning curve of robotic surgery. Univariate and multivariate linear regression models were used to assess factors affecting operative time (ORT).

Results

A total of 257 and 385 patients underwent RALP utilizing the VTS and conventional insufflation, respectively. There were no significant differences in American Society of Anesthesiologist score, body mass index (BMI), prostate volume, final Gleason score, estimated blood loss, and complications between the cohorts. The only difference noted was a significantly shorter mean ORT in the VTS cohort (149.5 vs. 170.1 min, p < 0.0001). In light of this finding, further analysis was performed to identify associations with ORT. Multivariable analysis demonstrated that VTS, BMI, final Gleason score, prostate volume, surgeon, and node dissection were significantly associated with ORT. The use of the VTS decreased mean ORT by 23.2 min when controlling for confounding factors (p < 0.001). The performance of a nerve sparing operation was found to decrease ORT by 15.9 min (p < 0.001), though more often performed for lower-risk disease.

Conclusion

The use of a novel VTS demonstrated decreased ORT in patients undergoing RALP when controlling for confounding factors. Prospective randomized trials are needed to evaluate its ultimate benefit in various surgical cohorts.
Literature
1.
go back to reference Barczynski M, Herman RM (2002) Influence of different pressures of pneumoperitoneum on the autonomic system function during laparoscopy. Folia Med Cracov 43:51–58PubMed Barczynski M, Herman RM (2002) Influence of different pressures of pneumoperitoneum on the autonomic system function during laparoscopy. Folia Med Cracov 43:51–58PubMed
2.
go back to reference Hazebroek EJ, Haitsma JJ, Lachmann B et al (2002) Impact of carbon dioxide and helium insufflation on cardiorespiratory function during prolonged pneumoperitoneum in an experimental rat model. Surg Endosc 16:1073–1078CrossRefPubMed Hazebroek EJ, Haitsma JJ, Lachmann B et al (2002) Impact of carbon dioxide and helium insufflation on cardiorespiratory function during prolonged pneumoperitoneum in an experimental rat model. Surg Endosc 16:1073–1078CrossRefPubMed
3.
go back to reference Herati AS, Andonian S, Rais-Bahrami S et al (2011) Use of the valveless trocar system reduces CO2 absorption during laparoscopy with compared with standard trocars. Urology 77:1126–1132CrossRefPubMed Herati AS, Andonian S, Rais-Bahrami S et al (2011) Use of the valveless trocar system reduces CO2 absorption during laparoscopy with compared with standard trocars. Urology 77:1126–1132CrossRefPubMed
4.
go back to reference Herati AS, Atalla MA, Rais-Bahrami S, Andonian S, Vira MA, Kavoussi LR (2009) A new valveless trocar for urologic laparoscopy: initial evaluation. J Endourol 23(9):1535–1539CrossRefPubMed Herati AS, Atalla MA, Rais-Bahrami S, Andonian S, Vira MA, Kavoussi LR (2009) A new valveless trocar for urologic laparoscopy: initial evaluation. J Endourol 23(9):1535–1539CrossRefPubMed
5.
go back to reference Tollefson MK, Frank I, Gettman MT (2011) Robotic-assisted radical prostatectomy decreases the incidence and morbidity of surgical site infections. Urology 78(4):827–831CrossRefPubMed Tollefson MK, Frank I, Gettman MT (2011) Robotic-assisted radical prostatectomy decreases the incidence and morbidity of surgical site infections. Urology 78(4):827–831CrossRefPubMed
6.
go back to reference Kordan Y, Barocas DA, Altamar HO et al (2010) Comparison of transfusion requirements between open and robotic-assisted laparoscopic radical prostatectomy. BJU Int 106(7):1036–1040CrossRefPubMed Kordan Y, Barocas DA, Altamar HO et al (2010) Comparison of transfusion requirements between open and robotic-assisted laparoscopic radical prostatectomy. BJU Int 106(7):1036–1040CrossRefPubMed
7.
go back to reference George AK, Herati AS, Srinivasan AK et al (2013) Perioperative outcomes of off-clamp vs complete hilar control laparoscopic partial nephrectomy. BJU Int 111(4 Pt B):E235–E241CrossRefPubMed George AK, Herati AS, Srinivasan AK et al (2013) Perioperative outcomes of off-clamp vs complete hilar control laparoscopic partial nephrectomy. BJU Int 111(4 Pt B):E235–E241CrossRefPubMed
8.
go back to reference George AK, Herati AS, Rais-Bahrami S, Waingankar N, Kavoussi LR (2014) Laparoscopic partial nephrectomy for hilar tumors: oncologic and renal functional outcomes. Urology 83(1):111–115CrossRefPubMed George AK, Herati AS, Rais-Bahrami S, Waingankar N, Kavoussi LR (2014) Laparoscopic partial nephrectomy for hilar tumors: oncologic and renal functional outcomes. Urology 83(1):111–115CrossRefPubMed
9.
go back to reference Hillelsohn JH, Friedlander JI, Bagadiya N et al (2012) Masked Pneumothorax: risk of valveless trocar systems. J Urol 189:955–959CrossRefPubMed Hillelsohn JH, Friedlander JI, Bagadiya N et al (2012) Masked Pneumothorax: risk of valveless trocar systems. J Urol 189:955–959CrossRefPubMed
10.
go back to reference Rais-Bahrami S, George AK, Herati AS, Srinivasan AK, Richstone L, Kavoussi LR (2012) Off-clamp versus complete hilar control laparoscopic partial nephrectomy: comparison by clinical stage. BJU Int 109(9):1376–1381CrossRefPubMed Rais-Bahrami S, George AK, Herati AS, Srinivasan AK, Richstone L, Kavoussi LR (2012) Off-clamp versus complete hilar control laparoscopic partial nephrectomy: comparison by clinical stage. BJU Int 109(9):1376–1381CrossRefPubMed
11.
go back to reference Leppert JT, Breda A, Harper JD, Schulam PG (2011) Laparoendoscopic single-site porcine nephrectomy using a novel valveless trocar system. J Endourol 25(1):119–122CrossRefPubMed Leppert JT, Breda A, Harper JD, Schulam PG (2011) Laparoendoscopic single-site porcine nephrectomy using a novel valveless trocar system. J Endourol 25(1):119–122CrossRefPubMed
12.
go back to reference Gurusamy KS, Samraj K, Davidson BR (2009) Low pressure versus standard pressure pneumoperitoneum in laparoscopic cholecystectomy. Cochrane Database Syst Rev 15(2):CD006930 Gurusamy KS, Samraj K, Davidson BR (2009) Low pressure versus standard pressure pneumoperitoneum in laparoscopic cholecystectomy. Cochrane Database Syst Rev 15(2):CD006930
13.
go back to reference Samadi D, Levinson A, Hakimi A, Shabsigh R, Benson MC (2007) From proficiency to expert, when does the learning curve for robotic-assisted prostatectomies plateau? The Columbia University experience. World J Urol 25(1):105–110CrossRefPubMed Samadi D, Levinson A, Hakimi A, Shabsigh R, Benson MC (2007) From proficiency to expert, when does the learning curve for robotic-assisted prostatectomies plateau? The Columbia University experience. World J Urol 25(1):105–110CrossRefPubMed
Metadata
Title
Utilization of a novel valveless trocar system during robotic-assisted laparoscopic prostatectomy
Authors
Arvin K. George
Reinhard Wimhofer
Kate V. Viola
Markus Pernegger
Walter Costamoling
Louis R. Kavoussi
Wolfgang Loidl
Publication date
01-11-2015
Publisher
Springer Berlin Heidelberg
Published in
World Journal of Urology / Issue 11/2015
Print ISSN: 0724-4983
Electronic ISSN: 1433-8726
DOI
https://doi.org/10.1007/s00345-015-1521-8

Other articles of this Issue 11/2015

World Journal of Urology 11/2015 Go to the issue