Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 7/2015

01-07-2015 | Knee

Using fibula as a reference can be beneficial for the tibial component alignment after total knee arthroplasty, a retrospective study

Authors: Mehmet Erdem, Deniz Gulabi, Gultekin Sitki Cecen, Cem Coskun Avci, Murat Asci, Fevzi Saglam

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 7/2015

Login to get access

Abstract

Purpose

One of the important factors in a successful arthroplasty is component alignment. The primary objective of this study was to determine whether the fibular shaft reference technique is beneficial for the tibial component position on the postoperative plain radiograph after total knee arthroplasty.

Methods

A total of 42 patients between 2009 and 2011 were analysed retrospectively. The surgeon prepared the tibia using an extramedullary cutting guide and set the posterior tibial slope with respect to the fibular reference rod. In the postoperative radiographic measurements, a true anteroposterior and lateral radiograph of the lower leg covering the whole length of the tibia was used.

Results

Five patients were excluded as they did not meet the inclusion criteria, four patients were excluded due to improper radiographs and the study group was reduced to 33 patients and 35 knees. The mean preoperative tibiofibular angle was 2.1° ± 0.8°. The mean postoperative tibial sagittal angle measurements were 83.3° ± 1.4° (81°–86°). 33 (94 %) Knees gained the desired tibial sagittal angle within the desired alignment (5° ± 3°). The mean postoperative tibial coronal angle was 89.3° ± 1.5°. The tibial component coronal angle of two knees was more than 3 alignment from the neutral mechanical axis.

Conclusion

The major clinical relevance of the technique described in the present study is cost-effectiveness, and it does not require any extra time or surgical equipment. This method can be used as an alternative choice for bulky extremities which is a cause of malalignment of the components.

Level of evidence

Retrospective case series, Level IV.
Literature
1.
go back to reference Bae DK, Song SJ, Yoon KH, Noh JH, Moon SC (2012) Comparative study of tibial posterior slope angle following cruciate-retaining total knee arthroplasty using one of three implants. Int Orthop 36:755–760PubMedCentralPubMedCrossRef Bae DK, Song SJ, Yoon KH, Noh JH, Moon SC (2012) Comparative study of tibial posterior slope angle following cruciate-retaining total knee arthroplasty using one of three implants. Int Orthop 36:755–760PubMedCentralPubMedCrossRef
2.
go back to reference Barrett WP, Mason JB, Moskal JT, Dalury DF, Oliashirazi A, Fisher DA (2011) Comparison of radiographic alignment of imageless computer-assisted surgery vs conventional instrumentation in primary total knee arthroplasty. J Arthroplast 26:1273–1284CrossRef Barrett WP, Mason JB, Moskal JT, Dalury DF, Oliashirazi A, Fisher DA (2011) Comparison of radiographic alignment of imageless computer-assisted surgery vs conventional instrumentation in primary total knee arthroplasty. J Arthroplast 26:1273–1284CrossRef
3.
go back to reference Bellemans J, Robijns F, Duerinckx J, Banks S, Vandenneucker H (2005) The influence of tibial slope on maximal flexion after total knee arthroplasty-. Knee Surg Sports Traumatol Arthrosc 13:193–196PubMedCrossRef Bellemans J, Robijns F, Duerinckx J, Banks S, Vandenneucker H (2005) The influence of tibial slope on maximal flexion after total knee arthroplasty-. Knee Surg Sports Traumatol Arthrosc 13:193–196PubMedCrossRef
4.
go back to reference Berend ME, Ritter MA, Meding JB, Faris PM, Keating EM, Redelman R, Faris GW, Davis KE (2004) Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res 428:26–34PubMedCrossRef Berend ME, Ritter MA, Meding JB, Faris PM, Keating EM, Redelman R, Faris GW, Davis KE (2004) Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res 428:26–34PubMedCrossRef
5.
go back to reference Brandt KD, Fife RS, Braunstein EM, Katz B (1991) Radiographic grading of the severity of knee osteoarthritis: relation of the Kellgren and Lawrence grade to a grade based on joint space narrowing, and correlation with arthroscopic evidence of articular cartilage degeneration-. Arthritis Rheum 34:1381–1386PubMedCrossRef Brandt KD, Fife RS, Braunstein EM, Katz B (1991) Radiographic grading of the severity of knee osteoarthritis: relation of the Kellgren and Lawrence grade to a grade based on joint space narrowing, and correlation with arthroscopic evidence of articular cartilage degeneration-. Arthritis Rheum 34:1381–1386PubMedCrossRef
6.
go back to reference Byrick RJ, Forbes D, Waddell JP (1986) A monitored cardiovascular collapse during cemented total knee replacement. Anesthesiology 65:213–216PubMedCrossRef Byrick RJ, Forbes D, Waddell JP (1986) A monitored cardiovascular collapse during cemented total knee replacement. Anesthesiology 65:213–216PubMedCrossRef
7.
go back to reference Chiu KY, Zhang SD, Zhang GH (2000) Posterior slope of tibial plateau in Chinese. J Arthroplast 15:224–227CrossRef Chiu KY, Zhang SD, Zhang GH (2000) Posterior slope of tibial plateau in Chinese. J Arthroplast 15:224–227CrossRef
8.
go back to reference Choi WC, Lee S, An JH, Kim D, Seong SC, Lee MC (2011) Plain radiograph fails to reflect the alignment and advantages of navigation in total knee arthroplasty. J Arthroplast 26:756–764CrossRef Choi WC, Lee S, An JH, Kim D, Seong SC, Lee MC (2011) Plain radiograph fails to reflect the alignment and advantages of navigation in total knee arthroplasty. J Arthroplast 26:756–764CrossRef
9.
go back to reference Ewald FC (1989) The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248:9–12PubMed Ewald FC (1989) The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248:9–12PubMed
10.
go back to reference Hofmann AA, Bachus KN, Wyatt RW (1991) Effect of the tibial cut on subsidence following total knee arthroplasty. Clin Orthop Relat Res 269:63–69PubMed Hofmann AA, Bachus KN, Wyatt RW (1991) Effect of the tibial cut on subsidence following total knee arthroplasty. Clin Orthop Relat Res 269:63–69PubMed
11.
go back to reference Insall JN, Ranawat CS, Aglietti P, Shine J (1976) A comparison of four models of total knee-replacement prostheses. J Bone Jt Surg Am 58:754–765 Insall JN, Ranawat CS, Aglietti P, Shine J (1976) A comparison of four models of total knee-replacement prostheses. J Bone Jt Surg Am 58:754–765
12.
go back to reference Iorio R, Bolle G, Conteduca F, Valeo L, Conteduca J, Mazza D, Ferretti A (2013) Accuracy of manual instrumentation of tibial cutting guide in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 21:2296–2300PubMedCrossRef Iorio R, Bolle G, Conteduca F, Valeo L, Conteduca J, Mazza D, Ferretti A (2013) Accuracy of manual instrumentation of tibial cutting guide in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 21:2296–2300PubMedCrossRef
13.
go back to reference Kansara D, Markel DC (2006) The effect of posterior tibial slope on range of motion after total knee arthroplasty. J Arthroplast 21:809–813CrossRef Kansara D, Markel DC (2006) The effect of posterior tibial slope on range of motion after total knee arthroplasty. J Arthroplast 21:809–813CrossRef
14.
go back to reference Karade V, Ravi B, Agarwal M (2012) Extramedullary versus intramedullary tibial cutting guides in megaprosthetic total knee replacement. J Orthop Surg Res 2(7):33CrossRef Karade V, Ravi B, Agarwal M (2012) Extramedullary versus intramedullary tibial cutting guides in megaprosthetic total knee replacement. J Orthop Surg Res 2(7):33CrossRef
15.
go back to reference Kawahara S, Okazaki K, Matsuda S, Mitsuyasu H, Nakahara H, Okamoto S, Iwamoto Y (2013) Medial sixth of the patellar tendon at the tibial attachment is useful fort he anterior reference in rotational alignment of the tibial component. Knee Surg Sports Traumatol Arthrosc. Mar 12. PMID: 23479057 (Epub ahead of print) Kawahara S, Okazaki K, Matsuda S, Mitsuyasu H, Nakahara H, Okamoto S, Iwamoto Y (2013) Medial sixth of the patellar tendon at the tibial attachment is useful fort he anterior reference in rotational alignment of the tibial component. Knee Surg Sports Traumatol Arthrosc. Mar 12. PMID: 23479057 (Epub ahead of print)
16.
go back to reference Keyes BJ, Markel DC, Meneghini RM (2013) Evaluation of limb alignment, component positioning, and function in primary total knee arthroplasty using a pinless navigation technique compared with conventional methods. J Knee Surg 26:127–132PubMed Keyes BJ, Markel DC, Meneghini RM (2013) Evaluation of limb alignment, component positioning, and function in primary total knee arthroplasty using a pinless navigation technique compared with conventional methods. J Knee Surg 26:127–132PubMed
17.
go back to reference Kim SJ, MacDonald M, Hernandez J, Wixson RL (2005) Computer assisted navigation in total knee arthroplasty: improved coronal alignment. J Arthroplast 20:123–131CrossRef Kim SJ, MacDonald M, Hernandez J, Wixson RL (2005) Computer assisted navigation in total knee arthroplasty: improved coronal alignment. J Arthroplast 20:123–131CrossRef
18.
19.
go back to reference Maestro A, Harwin SF, Sandoval MG, Vaquero DH, Murcia A (1998) Influence of intramedullary versus extramedullary alignment guides on final total knee arthroplasty component position: a radiographic analysis. J Arthroplast 13:552–558CrossRef Maestro A, Harwin SF, Sandoval MG, Vaquero DH, Murcia A (1998) Influence of intramedullary versus extramedullary alignment guides on final total knee arthroplasty component position: a radiographic analysis. J Arthroplast 13:552–558CrossRef
20.
go back to reference Mason JB, Fehring TK, Estok R, Banel D, Fahrbach K (2007) Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. J Arthroplast 22:1097–1106CrossRef Mason JB, Fehring TK, Estok R, Banel D, Fahrbach K (2007) Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. J Arthroplast 22:1097–1106CrossRef
21.
go back to reference Matsuda S, Miura H, Nagamine R, Urabe K, Ikenoue T, Okazaki K, Iwamoto Y (1999) Posterior tibial slope in the normal and varus knee. Am J Knee Surg 12:165–168PubMed Matsuda S, Miura H, Nagamine R, Urabe K, Ikenoue T, Okazaki K, Iwamoto Y (1999) Posterior tibial slope in the normal and varus knee. Am J Knee Surg 12:165–168PubMed
22.
go back to reference Matziolis G, Pfitzner T, Thiele K, Matziolis D, Perka C (2011) Influence of the position of the fibular head after ımplantation of a total knee prothesis on femorotibial rotation. Orthopedics 34:e610–e614PubMedCrossRef Matziolis G, Pfitzner T, Thiele K, Matziolis D, Perka C (2011) Influence of the position of the fibular head after ımplantation of a total knee prothesis on femorotibial rotation. Orthopedics 34:e610–e614PubMedCrossRef
23.
go back to reference Mullaji AB, Shetty GM, Lingaraju AP, Bhayde S (2013) Which factors increase risk of malalignment of the hip–knee–ankle axis in TKA? Clin Orthop Relat Res 471:134–141PubMedCentralPubMedCrossRef Mullaji AB, Shetty GM, Lingaraju AP, Bhayde S (2013) Which factors increase risk of malalignment of the hip–knee–ankle axis in TKA? Clin Orthop Relat Res 471:134–141PubMedCentralPubMedCrossRef
24.
go back to reference Nam D, Cody EA, Nguyen JT, Figgie MP, Mayman DJ (2014) Extramedullary guides versus portable, accelerometer-based navigation for tibial alignment in total knee arthroplasty: a randomized, controlled trial. J Arthroplast 29:288–294 Nam D, Cody EA, Nguyen JT, Figgie MP, Mayman DJ (2014) Extramedullary guides versus portable, accelerometer-based navigation for tibial alignment in total knee arthroplasty: a randomized, controlled trial. J Arthroplast 29:288–294
25.
go back to reference Nunley RM, Ellison BS, Ruh EL, Williams BM, Foreman K, Ford AD, Barrack RL (2012) Are patient-specific cutting blocks cost-effective for total knee arthroplasty? Clin Orthop Relat Res 470:889–894PubMedCentralPubMedCrossRef Nunley RM, Ellison BS, Ruh EL, Williams BM, Foreman K, Ford AD, Barrack RL (2012) Are patient-specific cutting blocks cost-effective for total knee arthroplasty? Clin Orthop Relat Res 470:889–894PubMedCentralPubMedCrossRef
26.
go back to reference Reed MR, Bliss W, Sher JL, Emmerson KP, Jones SM, Partington PF (2002) Extramedullary or intramedullary tibial alignment guides: a randomised, prospective trial of radiological alignment. J Bone Jt Surg Br 84:858–860CrossRef Reed MR, Bliss W, Sher JL, Emmerson KP, Jones SM, Partington PF (2002) Extramedullary or intramedullary tibial alignment guides: a randomised, prospective trial of radiological alignment. J Bone Jt Surg Br 84:858–860CrossRef
28.
go back to reference Samii K, Elmelik E, Mourtada MB, Debeyre J, Rapin M (1979) Intraoperative hemodynamic changes during total knee replacement. Anesthesiology 50:239–242PubMedCrossRef Samii K, Elmelik E, Mourtada MB, Debeyre J, Rapin M (1979) Intraoperative hemodynamic changes during total knee replacement. Anesthesiology 50:239–242PubMedCrossRef
29.
go back to reference Seo JG, Moon YW, Park SH, Shim JW, Kim SM (2012) An alternative method to create extramedullary references in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 20:1339–1348PubMedCrossRef Seo JG, Moon YW, Park SH, Shim JW, Kim SM (2012) An alternative method to create extramedullary references in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 20:1339–1348PubMedCrossRef
30.
go back to reference Skyttä ET, Lohman M, Tallroth K, Remes V (2009) Comparison of standard anteroposterior knee and hip-to-ankle radiographs in determining the lower limb and implant alignment after total knee arthroplasty. Scand J Surg 98:250–253PubMed Skyttä ET, Lohman M, Tallroth K, Remes V (2009) Comparison of standard anteroposterior knee and hip-to-ankle radiographs in determining the lower limb and implant alignment after total knee arthroplasty. Scand J Surg 98:250–253PubMed
31.
go back to reference Song EK, Seon JK, Yim JH, Netravali NA, Bargar WL (2013) Robotic-assisted TKA reduces postoperative alignment outliers and improves gap balance compared to conventional TKA. Clin Orthop Relat Res 471:118–126PubMedCentralPubMedCrossRef Song EK, Seon JK, Yim JH, Netravali NA, Bargar WL (2013) Robotic-assisted TKA reduces postoperative alignment outliers and improves gap balance compared to conventional TKA. Clin Orthop Relat Res 471:118–126PubMedCentralPubMedCrossRef
32.
go back to reference Whiteside LA, Amador DD (1988) The effect of posterior tibial slope on knee stability after ortholoc total knee arthroplasty. J Arthroplast 3:51–57CrossRef Whiteside LA, Amador DD (1988) The effect of posterior tibial slope on knee stability after ortholoc total knee arthroplasty. J Arthroplast 3:51–57CrossRef
33.
go back to reference Yoo JH, Chang CB, Shin KS, Seong SC, Kim TK (2008) Anatomical references to assess the posterior tibial slope in total knee arthroplasty: a comparison of 5 anatomical axes. J Arthroplast 23:586–592CrossRef Yoo JH, Chang CB, Shin KS, Seong SC, Kim TK (2008) Anatomical references to assess the posterior tibial slope in total knee arthroplasty: a comparison of 5 anatomical axes. J Arthroplast 23:586–592CrossRef
Metadata
Title
Using fibula as a reference can be beneficial for the tibial component alignment after total knee arthroplasty, a retrospective study
Authors
Mehmet Erdem
Deniz Gulabi
Gultekin Sitki Cecen
Cem Coskun Avci
Murat Asci
Fevzi Saglam
Publication date
01-07-2015
Publisher
Springer Berlin Heidelberg
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 7/2015
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-014-2957-x

Other articles of this Issue 7/2015

Knee Surgery, Sports Traumatology, Arthroscopy 7/2015 Go to the issue