Abstract

Background

It would be ideal if surgeons could precisely confirm whether the planned femoral component achieves the best fit and fill of implant and femur. However, the cortico-cancellous interfaces can be difficult to standardize using plain radiography, and therefore, determining the contact state is a subjective decision by the examiner. Few reports have described the use of CT-based three-dimensional templating software to quantify the contact state of stem and femur in detail. The purpose of this study was to use three-dimensional templating software to quantify the implant–femur contact state and develop a technique to analyze the initial fixation pattern of a cementless femoral stem.

Methods

We conducted a retrospective review of 55 hips in 53 patients using a short proximal fit-and-fill anatomical stem (APS Natural-Hip™ System). All femurs were examined by density mapping which can visualize and digitize the contact state. We evaluated the contact state of implant and femur by using density mapping.

Results

The varus group (cases that had changed varus 2° by 3 months after surgery) consisted of 11 hips. The varus group showed no significant difference with regard to cortical contact in the proximal medial portion (Gruen 7), but the contact area in the distal portion (Gruen 3 and Gruen 5) was significantly lower than that of non-varus group. Density mapping showed that the stem only has to be press-fit to the medial calcar, but also must fill the distal portion of the implant in order to achieve the ideal contact state.

Conclusions

Our results indicated that quantifying the contact state of implant and femur by using density mapping is a useful technique to accurately analyze the fixation pattern of a cementless femoral stem.
Literature
1.
2.
go back to reference Shaarani R, Gavin M, Denis A (2013) Accuracy of Digital preoperative templating in 100 consecutive uncemented total hip arthroplasties. J Arthroplasty 28(2):331–337CrossRefPubMed Shaarani R, Gavin M, Denis A (2013) Accuracy of Digital preoperative templating in 100 consecutive uncemented total hip arthroplasties. J Arthroplasty 28(2):331–337CrossRefPubMed
3.
go back to reference Issa K, Pivec R, Boyd B, Harwin SF, Wuestemann T, Nevelos J, Mont MA (2012) Comparing the accuracy of radiographic preoperative digital templating for a second-versus a first-generation THA stem. Orthopedics 35(12):1028–1034CrossRefPubMed Issa K, Pivec R, Boyd B, Harwin SF, Wuestemann T, Nevelos J, Mont MA (2012) Comparing the accuracy of radiographic preoperative digital templating for a second-versus a first-generation THA stem. Orthopedics 35(12):1028–1034CrossRefPubMed
4.
go back to reference Haddad FS, Masri BA, Garbuz DS, Duncan CP (1997) The prevention of periprosthetic fractures in total hip and knee arthroplasty. Orthop Clin North Am 30(2):191–207CrossRef Haddad FS, Masri BA, Garbuz DS, Duncan CP (1997) The prevention of periprosthetic fractures in total hip and knee arthroplasty. Orthop Clin North Am 30(2):191–207CrossRef
5.
go back to reference Dalton JE, Cook SD, Thomas KA, Kay JF (1995) The effect of operative fit and hydroxyapatite coating on the mechanical and biological response to porous implants. J Bone Joint Surg Am 77(1):97–110PubMed Dalton JE, Cook SD, Thomas KA, Kay JF (1995) The effect of operative fit and hydroxyapatite coating on the mechanical and biological response to porous implants. J Bone Joint Surg Am 77(1):97–110PubMed
6.
go back to reference Haraguchi K, Sugano N, Nishii T, Koyama T, Nishihara S, Yoshikawa H, Ochi T (2001) Comparison of fit and fill between anatomic stem and straight tapered stem using virtual implantation on the ORTHODOC workstation. Comput Aided Surg 6(5):290–296CrossRefPubMed Haraguchi K, Sugano N, Nishii T, Koyama T, Nishihara S, Yoshikawa H, Ochi T (2001) Comparison of fit and fill between anatomic stem and straight tapered stem using virtual implantation on the ORTHODOC workstation. Comput Aided Surg 6(5):290–296CrossRefPubMed
7.
go back to reference Nishihara S, Sugano N, Nishii T, Tanaka H, Yoshikawa H, Ochi A (2003) Comparison of the fit and fill between the Anatomic Hip femoral component and the Versys Taper femoral component using virtual implantation on the ORTHODOC workstation. J Orthop Sci 8(3):352–360CrossRefPubMed Nishihara S, Sugano N, Nishii T, Tanaka H, Yoshikawa H, Ochi A (2003) Comparison of the fit and fill between the Anatomic Hip femoral component and the Versys Taper femoral component using virtual implantation on the ORTHODOC workstation. J Orthop Sci 8(3):352–360CrossRefPubMed
8.
go back to reference Howard JL, Hui AJ, Bourne RB, McCalden RW, MacDonald SJ, Rorabeck CH (2004) A quantitative analysis of bone support comparing cementless tapered and distal fixation total hip replacements. J Arthroplasty 19(3):266–273CrossRefPubMed Howard JL, Hui AJ, Bourne RB, McCalden RW, MacDonald SJ, Rorabeck CH (2004) A quantitative analysis of bone support comparing cementless tapered and distal fixation total hip replacements. J Arthroplasty 19(3):266–273CrossRefPubMed
9.
go back to reference Aamodt A, Kvistad KA, Andersen E, Lund-Larsen J, Eine J, Benum P, Husby OS (1999) Determination of Hounsfield value for CT-based design of custom femoral stems. J Bone Joint Surg Br 81(1):143–147CrossRefPubMed Aamodt A, Kvistad KA, Andersen E, Lund-Larsen J, Eine J, Benum P, Husby OS (1999) Determination of Hounsfield value for CT-based design of custom femoral stems. J Bone Joint Surg Br 81(1):143–147CrossRefPubMed
10.
go back to reference Crowe JF, Mani VJ, Ranawat CS (1979) Total hip replacement in congenital dislocation and dysplasia of the hip. J Bone Joint Surg Am 61(1):15–23PubMed Crowe JF, Mani VJ, Ranawat CS (1979) Total hip replacement in congenital dislocation and dysplasia of the hip. J Bone Joint Surg Am 61(1):15–23PubMed
11.
go back to reference Kajino Y, Kabata T, Maeda T, Iwai S, Kuroda K, Fujita K, Tsuchiya H (2013) Strict component positioning is necessary in hip resurfacing. J Orthop Sci 18(2):290–297CrossRefPubMed Kajino Y, Kabata T, Maeda T, Iwai S, Kuroda K, Fujita K, Tsuchiya H (2013) Strict component positioning is necessary in hip resurfacing. J Orthop Sci 18(2):290–297CrossRefPubMed
13.
go back to reference Eckrich SG, Noble PC, Tullos HS (1994) Effect of rotation on the radiographic appearance of the femoral canal. J Arthroplasty 9(4):419–426CrossRefPubMed Eckrich SG, Noble PC, Tullos HS (1994) Effect of rotation on the radiographic appearance of the femoral canal. J Arthroplasty 9(4):419–426CrossRefPubMed
14.
go back to reference Rubin PJ, Leyvraz PF, Aubaniac JM, Argenson JN, Estève P, de Roguin B (1992) The morphology of the proximal femur. A three-dimensional radiographic analysis. J Bone Joint Surg Br 74(1):28–32PubMed Rubin PJ, Leyvraz PF, Aubaniac JM, Argenson JN, Estève P, de Roguin B (1992) The morphology of the proximal femur. A three-dimensional radiographic analysis. J Bone Joint Surg Br 74(1):28–32PubMed
15.
go back to reference Knight JL, Atwater RD (1992) Preoperative planning for total hip arthroplasty. Quantitating its utility and precision. J Arthroplasty 7:403–409CrossRefPubMed Knight JL, Atwater RD (1992) Preoperative planning for total hip arthroplasty. Quantitating its utility and precision. J Arthroplasty 7:403–409CrossRefPubMed
16.
go back to reference Inoue D, Kabata T, Maeda T, Kajino Y, Fujita K, Hasegawa K, Yamamoto T, Tsuchiya H (2015) Value of computed tomography-based three-dimensional surgical preoperative planning software in total hip arthroplasty with developmental dysplasia of the hip. J Orthop Sci 20(2):340–346CrossRefPubMed Inoue D, Kabata T, Maeda T, Kajino Y, Fujita K, Hasegawa K, Yamamoto T, Tsuchiya H (2015) Value of computed tomography-based three-dimensional surgical preoperative planning software in total hip arthroplasty with developmental dysplasia of the hip. J Orthop Sci 20(2):340–346CrossRefPubMed
17.
go back to reference Sariali E, Mouttet A, Pasquier G, Durante E, Catone Y (2009) Accuracy of reconstruction of the hip using computerized three-dimensional pre-operative planning and a cementless modular neck. J Bone Joint Surg Br 91(3):333–340CrossRefPubMed Sariali E, Mouttet A, Pasquier G, Durante E, Catone Y (2009) Accuracy of reconstruction of the hip using computerized three-dimensional pre-operative planning and a cementless modular neck. J Bone Joint Surg Br 91(3):333–340CrossRefPubMed
18.
go back to reference Hassani H, Cherix S, Ek ET, Rüdiger HA (2014) Comparisons of preoperative three-dimensional planning and surgical reconstruction in primary cementless total hip arthroplasty. J Arthroplasty 29(6):1273–1277CrossRefPubMed Hassani H, Cherix S, Ek ET, Rüdiger HA (2014) Comparisons of preoperative three-dimensional planning and surgical reconstruction in primary cementless total hip arthroplasty. J Arthroplasty 29(6):1273–1277CrossRefPubMed
19.
go back to reference McKellop H, Ebramzadeh E, Niederer PG, Sarmiento A (1991) Comparison of the stability of press-fit hip prosthesis femoral stems using a synthetic model femur. J Orthop Res 9(2):297–305CrossRefPubMed McKellop H, Ebramzadeh E, Niederer PG, Sarmiento A (1991) Comparison of the stability of press-fit hip prosthesis femoral stems using a synthetic model femur. J Orthop Res 9(2):297–305CrossRefPubMed
20.
go back to reference Garg A, Deland J, Walker PS (1985) Design of intramedullary femoral stems using computer graphics. Eng Med 14(2):89–93CrossRefPubMed Garg A, Deland J, Walker PS (1985) Design of intramedullary femoral stems using computer graphics. Eng Med 14(2):89–93CrossRefPubMed
21.
go back to reference Reuben JD, Chang CH, Akin JE, Lionberger DR (1992) A knowledge-based computer-aided design and manufacturing system for total hip replacement. Clin Orthop Relat Res 285:48–56PubMed Reuben JD, Chang CH, Akin JE, Lionberger DR (1992) A knowledge-based computer-aided design and manufacturing system for total hip replacement. Clin Orthop Relat Res 285:48–56PubMed
22.
go back to reference Testi D, Simeoni M, Zannoni C, Viceconti M (2004) Validation of two algorithms to evaluate the interface between bone and orthopaedic implants. Comput Methods Progr Biomed 74(2):143–150CrossRef Testi D, Simeoni M, Zannoni C, Viceconti M (2004) Validation of two algorithms to evaluate the interface between bone and orthopaedic implants. Comput Methods Progr Biomed 74(2):143–150CrossRef
23.
go back to reference Adam F, Hammer DS, Pape D, Kohn D (2002) Femoral anatomy, computed tomography and computer-aided design of prosthetic implants. Arch Orthop Trauma Surg 122(5):262–268CrossRefPubMed Adam F, Hammer DS, Pape D, Kohn D (2002) Femoral anatomy, computed tomography and computer-aided design of prosthetic implants. Arch Orthop Trauma Surg 122(5):262–268CrossRefPubMed
24.
go back to reference Ries MD, Lynch F, Jenkins P, Mick C, Richman J (1996) Varus migration of PCA stems. Orthopedics 19(7):585–586 Ries MD, Lynch F, Jenkins P, Mick C, Richman J (1996) Varus migration of PCA stems. Orthopedics 19(7):585–586
25.
go back to reference Huppertz A, Radmer S, Asbach P, Juran R, Schwenke C, Diederichs G, Hamm B, Sparmann M (2011) Computed tomography for preoperative planning in minimal invasive total hip arthroplasty: radiation and cost analysis. Eur J Radiol 78(3):406–413CrossRefPubMed Huppertz A, Radmer S, Asbach P, Juran R, Schwenke C, Diederichs G, Hamm B, Sparmann M (2011) Computed tomography for preoperative planning in minimal invasive total hip arthroplasty: radiation and cost analysis. Eur J Radiol 78(3):406–413CrossRefPubMed
Metadata
Title
Usefullness of three-dimensional templating software to quantify the contact state between implant and femur in total hip arthroplasty
Authors
Daisuke Inoue
Tamon Kabata
Toru Maeda
Yoshitomo Kajino
Kenji Fujita
Kazuhiro Hasegawa
Takashi Yamamoto
Tomoharu Takagi
Takaaki Ohmori
Hiroyuki Tsuchiya
Publication date
01-12-2015
Publisher
Springer Paris
Published in
European Journal of Orthopaedic Surgery & Traumatology / Issue 8/2015
Print ISSN: 1633-8065
Electronic ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-015-1705-3

Other articles of this Issue 8/2015

European Journal of Orthopaedic Surgery & Traumatology 8/2015 Go to the issue