Abstract

In recent years, several studies related to fixation systems have been published, but few suggest any variations of the Le Fort I osteotomy technique, and the use of plates and screws placed along the canine and zygomatic pillar are common. The 20-year-old patient with Crouzon syndrome presented with severe hypoplasia of the maxillary, mandibular prognathism, and class III facial pattern. The patient underwent orthognathic surgery and high Le Fort I osteotomy with the fixation of eight positional screws. The aim of this paper is to describe a different technique for the fixation in high maxillary osteotomies, which can be used in specific cases.
Literature
1.
go back to reference Araujo MM, Waite PD, Lemons JE (2001) Strength analysis of Le Fort I osteotomy fixation: titanium versus resorbable plates. J Oral Maxillofac Surg 59(9):1034e1039CrossRef Araujo MM, Waite PD, Lemons JE (2001) Strength analysis of Le Fort I osteotomy fixation: titanium versus resorbable plates. J Oral Maxillofac Surg 59(9):1034e1039CrossRef
2.
go back to reference Ueki K, Okabe K, Moroi A, Marukawa K, Sotobori M, Ishihara Y et al (2012) Maxillary stability after Le Fort I osteotomy using three different plate systems. Int J Oral Maxillofac Surg 41(8):942e948CrossRef Ueki K, Okabe K, Moroi A, Marukawa K, Sotobori M, Ishihara Y et al (2012) Maxillary stability after Le Fort I osteotomy using three different plate systems. Int J Oral Maxillofac Surg 41(8):942e948CrossRef
3.
go back to reference Murray RA, Upton LG, Rottman KR (2003) Comparison of the postsurgical stability of the Le Fort I osteotomy using 2-and 4- plate fixation. J Oral Maxillofac Surg 61:574–579CrossRefPubMed Murray RA, Upton LG, Rottman KR (2003) Comparison of the postsurgical stability of the Le Fort I osteotomy using 2-and 4- plate fixation. J Oral Maxillofac Surg 61:574–579CrossRefPubMed
4.
go back to reference Hoffman GR, Moloney FB (1996) The stability of facial osteotomies. Part 5. Maxillary advancement with miniplate and screw fixation. Aust Dent J 41:21CrossRefPubMed Hoffman GR, Moloney FB (1996) The stability of facial osteotomies. Part 5. Maxillary advancement with miniplate and screw fixation. Aust Dent J 41:21CrossRefPubMed
5.
go back to reference Luyk NH, Ward-Booth RP (1975) The stability of Le Fort I advancement osteotomies using bone plates without bone grafts. J Oral Surg 3:253 Luyk NH, Ward-Booth RP (1975) The stability of Le Fort I advancement osteotomies using bone plates without bone grafts. J Oral Surg 3:253
Metadata
Title
Use positional screws for Le Fort I osteotomy fixation: technical note
Authors
Rafael Linard Avelar
Maykel Sullyvan Marinho de Souza
Eduardo Costa Studart Soares
Rodrygo Nunes Tavares
Publication date
01-09-2017
Publisher
Springer Berlin Heidelberg
Published in
Oral and Maxillofacial Surgery / Issue 3/2017
Print ISSN: 1865-1550
Electronic ISSN: 1865-1569
DOI
https://doi.org/10.1007/s10006-017-0625-2

Other articles of this Issue 3/2017

Oral and Maxillofacial Surgery 3/2017 Go to the issue