Skip to main content
Top
Published in: BMC Pregnancy and Childbirth 1/2013

Open Access 01-12-2013 | Research article

Unexpected random urinary protein:creatinine ratio results–limitations of the pyrocatechol violet-dye method

Authors: Dane A De Silva, Anne C Halstead, Anne-Marie Côté, Yasser Sabr, Peter von Dadelszen, Laura A Magee

Published in: BMC Pregnancy and Childbirth | Issue 1/2013

Login to get access

Abstract

Background

For clinicians, it is important to rely on accurate laboratory results for patient care and optimal use of health care resources. We sought to explore our observations that urine protein:creatinine ratios (PrCr) ≥30 mg/mmol are seen not infrequently associated with normal pregnancy outcome.

Methods

Urine samples were collected prospectively from 160 pregnant women attending high-risk maternity clinics at a tertiary care facility. Urinary protein was measured using a pyrocatechol violet assay and urinary creatinine by an enzymatic method on Vitros analysers. Maternal/perinatal outcomes were abstracted from hospital records.

Results

91/233 (39.1%) samples had a PrCr ≥30 mg/mmol, especially when urinary creatinine concentration was <3 mM (94.1%) vs. ≥3 mM (16.4%) (p < 0.001). When using the last sample before delivery, 47/160 (29.4%) had a PrCr ≥30 mg/mmol in diluted urine vs. only 17/160 (15.4%) in more concentrated urine (p < 0.001); PrCr positive results were also more frequent among the 32 (20.0%) women with known normal pregnancy outcome (90.9% vs. 0) (p < 0.001). Using the same analyser, 0.12 g/L urinary protein was ‘detected’ in deionised water. Re-analysis of data from two cohorts revealed substantially less inflation of PrCr in dilute urine using a pyrogallol red assay.

Conclusions

Random urinary PrCr was overestimated in dilute urine when tested using a common pyrocatechol violet dye-based method. This effect was reduced in cohorts when pyrogallol red assays were used. False positive results can impact on diagnosis and patient care. This highlights the need for both clinical and laboratory quality improvement projects and standardization of laboratory protein measurement.
Appendix
Available only for authorised users
Literature
1.
go back to reference National Kidney Foundation: K/DOQI clinical practice guidelines for chronic kidney disease: evaluation, classification, and stratification. Am J Kidney Dis. 2002, 39 (2 Suppl 1): S1-S266. National Kidney Foundation: K/DOQI clinical practice guidelines for chronic kidney disease: evaluation, classification, and stratification. Am J Kidney Dis. 2002, 39 (2 Suppl 1): S1-S266.
2.
go back to reference Magee LA, Helewa M, Rey E, Cote AM, Douglas J, Gibson P, et al: SOGC clinical practice guideline: diagnosis, evaluation, and management of the hypertensive disorders of pregnancy. JOGC. 2008, 30 (Suppl 3): S1-S48.PubMed Magee LA, Helewa M, Rey E, Cote AM, Douglas J, Gibson P, et al: SOGC clinical practice guideline: diagnosis, evaluation, and management of the hypertensive disorders of pregnancy. JOGC. 2008, 30 (Suppl 3): S1-S48.PubMed
3.
go back to reference Clark WF, Kortas C, Suri RS, Moist LM, Salvadori M, Weir MA, et al: Excessive fluid intake as a novel cause of proteinuria. CMAJ. 2008, 178 (2): 173-175.CrossRefPubMedPubMedCentral Clark WF, Kortas C, Suri RS, Moist LM, Salvadori M, Weir MA, et al: Excessive fluid intake as a novel cause of proteinuria. CMAJ. 2008, 178 (2): 173-175.CrossRefPubMedPubMedCentral
4.
go back to reference Ortho-Clinical Diagnostics: Instructions for use: Vitros Chemistry Products CREA Slides. 2007, Rochester, NY: Ortho-Clinical Diagnostics Ortho-Clinical Diagnostics: Instructions for use: Vitros Chemistry Products CREA Slides. 2007, Rochester, NY: Ortho-Clinical Diagnostics
5.
go back to reference Ortho-Clinical Diagnostics: Instructions for use: Vitros Chemistry Products UPRO Slides. 2010, Rochester, NY: Ortho-Clinical Diagnostics Ortho-Clinical Diagnostics: Instructions for use: Vitros Chemistry Products UPRO Slides. 2010, Rochester, NY: Ortho-Clinical Diagnostics
6.
go back to reference Cote AM, Firoz T, Mattman A, Lam EM, Von Dadelszen P, Magee LA: The 24-hour urine collection: gold standard or historical practice?. Am J Obstet Gynecol. 2008, 199 (6): 625-626.CrossRefPubMed Cote AM, Firoz T, Mattman A, Lam EM, Von Dadelszen P, Magee LA: The 24-hour urine collection: gold standard or historical practice?. Am J Obstet Gynecol. 2008, 199 (6): 625-626.CrossRefPubMed
7.
go back to reference Von Dadelszen P, Payne B, Li J, Ansermino JM, Broughton PF, Cote AM, et al: Prediction of adverse maternal outcomes in pre-eclampsia: development and validation of the fullPIERS model. Lancet. 2011, 377 (9761): 219-227. 10.1016/S0140-6736(10)61351-7.CrossRefPubMed Von Dadelszen P, Payne B, Li J, Ansermino JM, Broughton PF, Cote AM, et al: Prediction of adverse maternal outcomes in pre-eclampsia: development and validation of the fullPIERS model. Lancet. 2011, 377 (9761): 219-227. 10.1016/S0140-6736(10)61351-7.CrossRefPubMed
8.
go back to reference Koopmans CM, Biilenga D, Groen H, Vijgen SM, Aarnoudse JG, Bekedam DJ, et al: Induction of labour verses expectant monitoring for gestational hypertension or mild pre-eclampsia after 36 weeks’ gestation (HYPITAT): a multicentre, open-label randomised controlled trial. Lancet. 2009, 374 (9694): 979-988. 10.1016/S0140-6736(09)60736-4.CrossRefPubMed Koopmans CM, Biilenga D, Groen H, Vijgen SM, Aarnoudse JG, Bekedam DJ, et al: Induction of labour verses expectant monitoring for gestational hypertension or mild pre-eclampsia after 36 weeks’ gestation (HYPITAT): a multicentre, open-label randomised controlled trial. Lancet. 2009, 374 (9694): 979-988. 10.1016/S0140-6736(09)60736-4.CrossRefPubMed
9.
go back to reference Magee LA, Yong PJ, Espinosa V, Cote AM, Chen I, Von Dadelszen P: Expectant management of severe Preeclampsia remote from term: a structured systematic review. Hypertens Pregnancy. 2009, 28 (3): 312-347. 10.1080/10641950802601252.CrossRefPubMed Magee LA, Yong PJ, Espinosa V, Cote AM, Chen I, Von Dadelszen P: Expectant management of severe Preeclampsia remote from term: a structured systematic review. Hypertens Pregnancy. 2009, 28 (3): 312-347. 10.1080/10641950802601252.CrossRefPubMed
10.
go back to reference De Buys Roessingh AS, Drukker A, Guignard JP: Dipstick measurements of urine specific gravity are unreliable. Arch Dis Child. 2001, 85 (2): 155-157. 10.1136/adc.85.2.155.CrossRefPubMed De Buys Roessingh AS, Drukker A, Guignard JP: Dipstick measurements of urine specific gravity are unreliable. Arch Dis Child. 2001, 85 (2): 155-157. 10.1136/adc.85.2.155.CrossRefPubMed
11.
go back to reference Dube J, Girouard J, Leclerc P, Douville P: Problems with the estimation of urine protein by automated assays. Clin Biochem. 2005, 38 (5): 479-485. 10.1016/j.clinbiochem.2004.12.010.CrossRefPubMed Dube J, Girouard J, Leclerc P, Douville P: Problems with the estimation of urine protein by automated assays. Clin Biochem. 2005, 38 (5): 479-485. 10.1016/j.clinbiochem.2004.12.010.CrossRefPubMed
12.
go back to reference Lynch PLM, Savory J, Haverstick DM: Urine total protein measurement with the vitros dry reagent technology: modification of diluent to resolve positive bias of diluted samples. Clin Chem. 1998, 44 (3): 674-675.PubMed Lynch PLM, Savory J, Haverstick DM: Urine total protein measurement with the vitros dry reagent technology: modification of diluent to resolve positive bias of diluted samples. Clin Chem. 1998, 44 (3): 674-675.PubMed
13.
go back to reference De Silva DA, Halstead AC, Cote AM, Sabr Y, Von Dadelszen P, Magee LA: Random urine albumin:creatinine ratio in high-risk pregnancy – Is it clinically useful?. Preg Hyper: An Int J Women’s Card Health. 2013, 3 (2): 112-114. De Silva DA, Halstead AC, Cote AM, Sabr Y, Von Dadelszen P, Magee LA: Random urine albumin:creatinine ratio in high-risk pregnancy – Is it clinically useful?. Preg Hyper: An Int J Women’s Card Health. 2013, 3 (2): 112-114.
14.
go back to reference Cote AM, Brown MA, Lam E, Von Dadelszen P, Firoz T, Liston RM, et al: Diagnostic accuracy of urinary spot protein:creatinine ratio for proteinuria in hypertensive pregnant women: systematic review. BMJ. 2008, 336 (7651): 1003-1011. 10.1136/bmj.39532.543947.BE.CrossRefPubMedPubMedCentral Cote AM, Brown MA, Lam E, Von Dadelszen P, Firoz T, Liston RM, et al: Diagnostic accuracy of urinary spot protein:creatinine ratio for proteinuria in hypertensive pregnant women: systematic review. BMJ. 2008, 336 (7651): 1003-1011. 10.1136/bmj.39532.543947.BE.CrossRefPubMedPubMedCentral
15.
go back to reference Komenda P, Beaulieu M, Seccombe D, Levin A: Regional implementation of creatinine measurement standardization. J Am Soc Nephrol. 2009, 19 (1): 164-169.CrossRef Komenda P, Beaulieu M, Seccombe D, Levin A: Regional implementation of creatinine measurement standardization. J Am Soc Nephrol. 2009, 19 (1): 164-169.CrossRef
Metadata
Title
Unexpected random urinary protein:creatinine ratio results–limitations of the pyrocatechol violet-dye method
Authors
Dane A De Silva
Anne C Halstead
Anne-Marie Côté
Yasser Sabr
Peter von Dadelszen
Laura A Magee
Publication date
01-12-2013
Publisher
BioMed Central
Published in
BMC Pregnancy and Childbirth / Issue 1/2013
Electronic ISSN: 1471-2393
DOI
https://doi.org/10.1186/1471-2393-13-152

Other articles of this Issue 1/2013

BMC Pregnancy and Childbirth 1/2013 Go to the issue