01-07-2019 | Ultrasound | Original Article

Fast adaptive beamforming through a cascade structure for ultrasound imaging

Authors: Seyede Elham Shamsian, Sayed Mahmoud Sakhaei

Published in: Journal of Medical Ultrasonics | Issue 3/2019

Login to get access

Abstract

Purpose

A major limiting factor for applying a minimum variance (MV) beamformer in medical ultrasound imaging is its high computational complexity. This paper introduces a new fast MV beamforming method with almost the same capabilities as the standard MV.

Methods

The fast beamformer is implemented using a cascade structure. At the first stage, the echo signals received from the points far from the main axis are strongly suppressed using a fixed-weight beamformer. At the second stage, after spatially decimating the output of the first stage, an MV-based adaptive beamformer is used to eliminate the echo signals from the points adjacent to the focal point. The greatest advantage of the proposed method is that the second beamformer can be a low-complexity implementation of MV such as beamspace (BS) MV to further reduce the complexity, resulting in a superfast MV.

Results

The resulting beamformers were evaluated through both simulation and experimental data, and it was verified that the method was competitive with standard MV and BS methods at a lower computational cost.

Conclusion

The new fast and superfast MV methods are capable of obtaining the same results as the MV and BS-MV, at a significantly lower computational cost.
Literature
1.
go back to reference Synnevag JF, Austeng A, Holm S. Adaptive beamforming applied to medical ultrasound imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2007;54:1606–13.CrossRefPubMed Synnevag JF, Austeng A, Holm S. Adaptive beamforming applied to medical ultrasound imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2007;54:1606–13.CrossRefPubMed
2.
go back to reference Holfort IK, Gran F, Jensen JA. Broadband minimum variance beamforming for ultrasound imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2009;56:314–25.CrossRefPubMed Holfort IK, Gran F, Jensen JA. Broadband minimum variance beamforming for ultrasound imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2009;56:314–25.CrossRefPubMed
3.
go back to reference Synnevag JF, Austeng A, Holm S. Benefits of minimum-variance beamforming in medical ultrasound imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2009;56:1868–79.CrossRefPubMed Synnevag JF, Austeng A, Holm S. Benefits of minimum-variance beamforming in medical ultrasound imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2009;56:1868–79.CrossRefPubMed
4.
go back to reference Asl BM, Mahloojifar A. Eigenspace-based minimum variance beamforming applied to medical ultrasound imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2010;57:2381–90.CrossRef Asl BM, Mahloojifar A. Eigenspace-based minimum variance beamforming applied to medical ultrasound imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2010;57:2381–90.CrossRef
5.
go back to reference Mehdizade S, Austeng A, Johansen TF, et al. Eigenspace based minimum variance beamforming applied to ultrasound imaging of acoustically hard tissues. IEEE Trans Med Imaging. 2012;31:1912–21.CrossRef Mehdizade S, Austeng A, Johansen TF, et al. Eigenspace based minimum variance beamforming applied to ultrasound imaging of acoustically hard tissues. IEEE Trans Med Imaging. 2012;31:1912–21.CrossRef
6.
go back to reference Hasegawa H. Improvement of penetration of modified amplitude and phase estimation beamformer. J Med Ultrason. 2017;44:3–11.CrossRef Hasegawa H. Improvement of penetration of modified amplitude and phase estimation beamformer. J Med Ultrason. 2017;44:3–11.CrossRef
7.
go back to reference Hasegawa H. Apodized adaptive beamformer. J Med Ultrason. 2017;44:155–65.CrossRef Hasegawa H. Apodized adaptive beamformer. J Med Ultrason. 2017;44:155–65.CrossRef
8.
go back to reference Sakhaei SM, Shamsian SE. Twofold minimum variance beamforming for enhanced ultrasound imaging. J Med Ultrason. 2018;45:17–24.CrossRef Sakhaei SM, Shamsian SE. Twofold minimum variance beamforming for enhanced ultrasound imaging. J Med Ultrason. 2018;45:17–24.CrossRef
9.
go back to reference Nilsen CC, Hafizovic I. Beamspace adaptive beamforming for ultrasound imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2009;56:2187–97.CrossRefPubMed Nilsen CC, Hafizovic I. Beamspace adaptive beamforming for ultrasound imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2009;56:2187–97.CrossRefPubMed
10.
go back to reference Deylami AM, Asl BM. A fast and robust beamspace adaptive beamformer for medical ultrasound imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2017;64:947–58.CrossRef Deylami AM, Asl BM. A fast and robust beamspace adaptive beamformer for medical ultrasound imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2017;64:947–58.CrossRef
11.
go back to reference Bae M, Park SB, Kwon SJ. Legendre polynomial based fast minimum variance beamforming method for medical ultrasound systems. Electron Lett. 2014;50:1570–2.CrossRef Bae M, Park SB, Kwon SJ. Legendre polynomial based fast minimum variance beamforming method for medical ultrasound systems. Electron Lett. 2014;50:1570–2.CrossRef
12.
go back to reference Kim K, Park S, Kim J, et al. A fast minimum variance beamforming method using principal component analysis. IEEE Trans Ultrason Ferroelectr Freq Control. 2014;61:930–45.CrossRefPubMed Kim K, Park S, Kim J, et al. A fast minimum variance beamforming method using principal component analysis. IEEE Trans Ultrason Ferroelectr Freq Control. 2014;61:930–45.CrossRefPubMed
13.
go back to reference Asl BM, Mahloojifar A. A low-complexity adaptive beamformer for ultrasound imaging using structured covariance matrix. IEEE Trans Ultrason Ferroelectr Freq Control. 2012;59:660–7.CrossRefPubMed Asl BM, Mahloojifar A. A low-complexity adaptive beamformer for ultrasound imaging using structured covariance matrix. IEEE Trans Ultrason Ferroelectr Freq Control. 2012;59:660–7.CrossRefPubMed
14.
go back to reference Park J, Wi SM, Lee JS. Computationally efficient adaptive beamformer for ultrasound imaging based on QR decomposition. IEEE Trans Ultrason Ferroelectr Freq Control. 2016;63:256–65.CrossRefPubMed Park J, Wi SM, Lee JS. Computationally efficient adaptive beamformer for ultrasound imaging based on QR decomposition. IEEE Trans Ultrason Ferroelectr Freq Control. 2016;63:256–65.CrossRefPubMed
15.
go back to reference Synnevag JF, Austeng A, Holm S. A low-complexity data-dependent beamformer. IEEE Trans Ultrason Ferroelectr Freq Control. 2011;58:281–9.CrossRefPubMed Synnevag JF, Austeng A, Holm S. A low-complexity data-dependent beamformer. IEEE Trans Ultrason Ferroelectr Freq Control. 2011;58:281–9.CrossRefPubMed
16.
go back to reference Sakhaei SM. A decimated minimum variance beamforming for ultrasound imaging. Ultrasonics. 2015;59:119–27.CrossRefPubMed Sakhaei SM. A decimated minimum variance beamforming for ultrasound imaging. Ultrasonics. 2015;59:119–27.CrossRefPubMed
17.
go back to reference Shan TG, Wax M, Kailath T. On spatial smoothing for direction-of-arrival estimation of coherent signals. IEEE Trans Acoust Speech Signal Process. 1985;33:806–11.CrossRef Shan TG, Wax M, Kailath T. On spatial smoothing for direction-of-arrival estimation of coherent signals. IEEE Trans Acoust Speech Signal Process. 1985;33:806–11.CrossRef
18.
go back to reference Synnevag JF, Austeng A, Holm S. Speckle statistics in adaptive beamforming. In: Proceedings of IEEE Ultrasonics Symposium, 28–31 Oct 2007. IEEE, p. 1545–8. Synnevag JF, Austeng A, Holm S. Speckle statistics in adaptive beamforming. In: Proceedings of IEEE Ultrasonics Symposium, 28–31 Oct 2007. IEEE, p. 1545–8.
19.
go back to reference Jeong MK. A Fourier transform-based sidelobe reduction method in ultrasound imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2000;47:759–63.CrossRefPubMed Jeong MK. A Fourier transform-based sidelobe reduction method in ultrasound imaging. IEEE Trans Ultrason Ferroelectr Freq Control. 2000;47:759–63.CrossRefPubMed
20.
go back to reference Naidu PS. Sensor array signal processing. CRC Press; 2009. Naidu PS. Sensor array signal processing. CRC Press; 2009.
21.
go back to reference Jensen JA. Field: a program for simulating ultrasound systems. Med Biol Eng Comput. 1996;34:351–3.CrossRef Jensen JA. Field: a program for simulating ultrasound systems. Med Biol Eng Comput. 1996;34:351–3.CrossRef
22.
go back to reference O’Donnell M, Flax SW. Phase-aberration correction using signal from point reflectors and diffuse scatterers: measurements. IEEE Trans Ultrason Ferroelectr Freq Control. 1998;35:768–74.CrossRef O’Donnell M, Flax SW. Phase-aberration correction using signal from point reflectors and diffuse scatterers: measurements. IEEE Trans Ultrason Ferroelectr Freq Control. 1998;35:768–74.CrossRef
23.
go back to reference Krishnan S, Rigby KW, O’Donnell M. Improved estimation of phase aberration profile. IEEE Trans Ultrason Ferroelectr Freq Control. 1997;44:701–13.CrossRef Krishnan S, Rigby KW, O’Donnell M. Improved estimation of phase aberration profile. IEEE Trans Ultrason Ferroelectr Freq Control. 1997;44:701–13.CrossRef
Metadata
Title
Fast adaptive beamforming through a cascade structure for ultrasound imaging
Authors
Seyede Elham Shamsian
Sayed Mahmoud Sakhaei
Publication date
01-07-2019
Publisher
Springer Singapore
Published in
Journal of Medical Ultrasonics / Issue 3/2019
Print ISSN: 1346-4523
Electronic ISSN: 1613-2254
DOI
https://doi.org/10.1007/s10396-019-00930-w

Other articles of this Issue 3/2019

Journal of Medical Ultrasonics 3/2019 Go to the issue