Abstract

Background

Ultrasound guidance during central line insertion has significantly reduced complications associated with this procedure and has led to it being incorporated as standard of care in many institutions. However, inadvertent arterial penetration and dilation remains a problem despite ultrasound guidance and can result in significant morbidity and even mortality. Dynamic ultrasound confirmation of guidewire position within the vein prior to dilation may help to prevent and even eliminate this feared complication.

Methods

A prospectively collected database of central line insertions for one author utilizing this novel technique was retrospectively reviewed for all incidents of arterial dilation over a period from September 2008 to January 2010.

Results

During the study period 53 central lines were inserted with no incidents of arterial dilation.

Conclusions

Ultrasound confirmation of guidewire position has the potential to reduce or eliminate the morbidity and mortality of arterial dilation during central line placement.
Appendix
Available only for authorised users
Literature
1.
go back to reference Randolph AG, Cook DJ, Gonzales CA, Pribble CG: Ultrasound guidance for placement of central venous catheters: a meta-analysis of the literature. Crit Care Med. 1996, 24: 2053-2058. 10.1097/00003246-199612000-00020.CrossRefPubMed Randolph AG, Cook DJ, Gonzales CA, Pribble CG: Ultrasound guidance for placement of central venous catheters: a meta-analysis of the literature. Crit Care Med. 1996, 24: 2053-2058. 10.1097/00003246-199612000-00020.CrossRefPubMed
2.
go back to reference Hind D, Calvert N, McWilliams R, Davidson A, Paisley S, Beverley C, Thomas S: Ultrasonic locating devices for central venous cannulation: meta-analysis. BMJ. 2003, 327: 361-364. 10.1136/bmj.327.7411.361.PubMedCentralCrossRefPubMed Hind D, Calvert N, McWilliams R, Davidson A, Paisley S, Beverley C, Thomas S: Ultrasonic locating devices for central venous cannulation: meta-analysis. BMJ. 2003, 327: 361-364. 10.1136/bmj.327.7411.361.PubMedCentralCrossRefPubMed
3.
go back to reference Gualtieri E, Deppe SA, Sipperly ME, Thompson DR: Subclavian venous catheterization: greater success rate for less experienced operators using ultrasound guidance. Crit Care Med. 1995, 23: 692-7. 10.1097/00003246-199504000-00018.CrossRefPubMed Gualtieri E, Deppe SA, Sipperly ME, Thompson DR: Subclavian venous catheterization: greater success rate for less experienced operators using ultrasound guidance. Crit Care Med. 1995, 23: 692-7. 10.1097/00003246-199504000-00018.CrossRefPubMed
4.
go back to reference Keenan SP: Use of ultrasound to place central lines. J Crit Care. 2002, 17: 126-37. 10.1053/jcrc.2002.34364.CrossRefPubMed Keenan SP: Use of ultrasound to place central lines. J Crit Care. 2002, 17: 126-37. 10.1053/jcrc.2002.34364.CrossRefPubMed
5.
go back to reference Blaivas M: Video analysis of accidental arterial cannulation with dynamic ultrasound guidance for central venous access. J Ultrasound Med. 2009, 28: 1239-1244.PubMed Blaivas M: Video analysis of accidental arterial cannulation with dynamic ultrasound guidance for central venous access. J Ultrasound Med. 2009, 28: 1239-1244.PubMed
6.
go back to reference Shojania KG, Duncan BW, McDonald KM, Wachter RM, Markowitz AJ: Making health care safer: a critical analysis of patient safety practices. Evid Rep Technol Assess (Summ). 2001, 43: i-x. 1-668 Shojania KG, Duncan BW, McDonald KM, Wachter RM, Markowitz AJ: Making health care safer: a critical analysis of patient safety practices. Evid Rep Technol Assess (Summ). 2001, 43: i-x. 1-668
7.
go back to reference Sadler DJ, Gordon AC, Klassen J, Saliken JC, So CB, Gray RR: Image-guided central venous catheters for apheresis. Bone Marrow Transplant. 1999, 23: 179-82. 10.1038/sj.bmt.1701545.CrossRefPubMed Sadler DJ, Gordon AC, Klassen J, Saliken JC, So CB, Gray RR: Image-guided central venous catheters for apheresis. Bone Marrow Transplant. 1999, 23: 179-82. 10.1038/sj.bmt.1701545.CrossRefPubMed
8.
go back to reference Lichtenstein D, Menu Y: A bedside ultrasound sign ruling out pneumothorax in the critically ill: lung sliding. Chest. 1995, 108: 1345-1348. 10.1378/chest.108.5.1345.CrossRefPubMed Lichtenstein D, Menu Y: A bedside ultrasound sign ruling out pneumothorax in the critically ill: lung sliding. Chest. 1995, 108: 1345-1348. 10.1378/chest.108.5.1345.CrossRefPubMed
9.
go back to reference Panebianco NL, Fredette JM, Szyld D, Pines JM, Dean AJ: What you see (sonographically) is what you get: vein and patient characteristics associated with successful ultrasound-guided peripheral intravenous placement in patients with difficult access. Acad Emerg Med. 2009, 16: 1298-1303. 10.1111/j.1553-2712.2009.00520.x.CrossRefPubMed Panebianco NL, Fredette JM, Szyld D, Pines JM, Dean AJ: What you see (sonographically) is what you get: vein and patient characteristics associated with successful ultrasound-guided peripheral intravenous placement in patients with difficult access. Acad Emerg Med. 2009, 16: 1298-1303. 10.1111/j.1553-2712.2009.00520.x.CrossRefPubMed
10.
go back to reference Brannam L, Blaivas M, Lyon M, Flake M: Emergency nurses' utilization of ultrasound guidance for placement of peripheral intravenous lines in difficult-access patients. Acad Emerg Med. 2004, 11: 1361-3. 10.1111/j.1553-2712.2004.tb01929.x.CrossRefPubMed Brannam L, Blaivas M, Lyon M, Flake M: Emergency nurses' utilization of ultrasound guidance for placement of peripheral intravenous lines in difficult-access patients. Acad Emerg Med. 2004, 11: 1361-3. 10.1111/j.1553-2712.2004.tb01929.x.CrossRefPubMed
11.
go back to reference Finlay DJ, Sanchez LA, Sicard GA: Subclavian artery injury, vertebral artery dissection, and arteriovenous fistulae following attempt at central line placement. Ann Vasc Surg. 2002, 16: 774-8. 10.1007/s10016-001-0196-3.CrossRefPubMed Finlay DJ, Sanchez LA, Sicard GA: Subclavian artery injury, vertebral artery dissection, and arteriovenous fistulae following attempt at central line placement. Ann Vasc Surg. 2002, 16: 774-8. 10.1007/s10016-001-0196-3.CrossRefPubMed
12.
go back to reference Haaverstad R, Latto PN, Vitale N: Right subclavian catheter perforation of the aorta due to an incorrect external landmark-guided insertion technique. CJEM. 2007, 9: 43-5.PubMed Haaverstad R, Latto PN, Vitale N: Right subclavian catheter perforation of the aorta due to an incorrect external landmark-guided insertion technique. CJEM. 2007, 9: 43-5.PubMed
13.
go back to reference Ramamoorthy R, Wong CF, Murphy M, Gould D, Hammad A: Iatrogenic pseudo-aneurysm of the subclavian artery and dissection of the aorta, secondary to central venous line insertion: a treatment dilemma!. Nephrol Dial Transplant. 2006, 21: 1447-8. 10.1093/ndt/gfi271.CrossRefPubMed Ramamoorthy R, Wong CF, Murphy M, Gould D, Hammad A: Iatrogenic pseudo-aneurysm of the subclavian artery and dissection of the aorta, secondary to central venous line insertion: a treatment dilemma!. Nephrol Dial Transplant. 2006, 21: 1447-8. 10.1093/ndt/gfi271.CrossRefPubMed
14.
go back to reference Singleton RJ, Webb RK, Ludbrook GL, Fox MA: The Australian Incident Monitoring Study. Problems associated with vascular access: an analysis of 2000 incident reports. Anaesth Intensive Care. 1993, 21: 664-9.PubMed Singleton RJ, Webb RK, Ludbrook GL, Fox MA: The Australian Incident Monitoring Study. Problems associated with vascular access: an analysis of 2000 incident reports. Anaesth Intensive Care. 1993, 21: 664-9.PubMed
15.
go back to reference Blaivas M, Adhikari S: An unseen danger: frequency of posterior vessel wall penetration by needles during attempts to place internal jugular vein central catheters using ultrasound guidance. Crit Care Med. 2009, 37: 2345-2349. 10.1097/CCM.0b013e3181a067d4.CrossRefPubMed Blaivas M, Adhikari S: An unseen danger: frequency of posterior vessel wall penetration by needles during attempts to place internal jugular vein central catheters using ultrasound guidance. Crit Care Med. 2009, 37: 2345-2349. 10.1097/CCM.0b013e3181a067d4.CrossRefPubMed
Metadata
Title
Ultrasound confirmation of guidewire position may eliminate accidental arterial dilatation during central venous cannulation
Authors
Lawrence M Gillman
Michael Blaivas
Jason Lord
Azzam Al-Kadi
Andrew W Kirkpatrick
Publication date
01-12-2010
Publisher
BioMed Central
DOI
https://doi.org/10.1186/1757-7241-18-39

Other articles of this Issue 1/2010

Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine 1/2010 Go to the issue