Abstract

Background

This is the first study assessing the properties of large-diameter degradable sutures relevant for orthopedic applications over the course of in vitro incubation for 2 months. The data we present here provide guidance to the orthopedic surgeon in predicting the long-term performance of suture materials used everyday in surgical practice.

Methods

Five different absorbable (Vicryl, Maxon, Monocryl, PDS II, Vicryl rapide) and one non-absorbable (Ethibond) suture materials were tested. Measurements were made at five time points during the 56 days of incubation under physiological conditions (37.0 ± 0.02 °C; pH 7.4 ± 0.2). The following variables were recorded: load to failure, strain at maximal load as elongation normalized to original length, stiffness as the ratio of load to displacement on the linear proportion of the stress strain curve, and hysteresis as area under the curve of the stress strain curve.

Results

Vicryl was the strongest fiber on day 0 (195 N); however, by day 42, the tensile strength of the suture reduced to 14 N. Between days 14 and 28, PDS II (171 N) and Maxon (182 N) sustained the highest loads. Monocryl (p = 0.003) and Maxon (p < 0.001) showed an increasing strain with time, whereas Vicryl (p = 0.002) and Vicryl rapide (p = 0.007) revealed an increasing material stiffness. Furthermore, both Vicryl (p = 0.053) and Monocryl (p < 0.001) had an increasing hysteresis with ongoing degradation. Maxon, PDS II, and Ethibond showed stable material properties during the 2 months.

Conclusions

The three absorbable sutures Vicryl, PDS II, and Maxon could sustain higher loads during the first 2 weeks than the non-absorbable Ethibond. Unexpectedly, Maxon and PDS II maintained their elastic properties in spite of their proceeding degradation and loss of tensile strength.
Literature
2.
go back to reference Gerber C, Schneeberger AG, Perren SM, Nyffeler RW. Experimental rotator cuff repair. A preliminary study. J Bone Joint Surg Am. 1999;81(9):1281–90.PubMed Gerber C, Schneeberger AG, Perren SM, Nyffeler RW. Experimental rotator cuff repair. A preliminary study. J Bone Joint Surg Am. 1999;81(9):1281–90.PubMed
3.
go back to reference Chu CC, Moncrief G. An in vitro evaluation of the stability of mechanical properties of surgical suture materials in various pH conditions. Annals of surgery. 1983;198(2):223-8. Chu CC, Moncrief G. An in vitro evaluation of the stability of mechanical properties of surgical suture materials in various pH conditions. Annals of surgery. 1983;198(2):223-8.
4.
6.
go back to reference Debus ES, Geiger D, Sailer M, Ederer J, Thiede A. Physical, biological and handling characteristics of surgical suture material: a comparison of four different multifilament absorbable sutures. Eur Surg Res. 1997;29(1):52–61.CrossRefPubMed Debus ES, Geiger D, Sailer M, Ederer J, Thiede A. Physical, biological and handling characteristics of surgical suture material: a comparison of four different multifilament absorbable sutures. Eur Surg Res. 1997;29(1):52–61.CrossRefPubMed
8.
go back to reference Lunstedt B, Knoop M, Thiede A. Review of the physical and surgical technical properties of modern monofilament suture materials. Chirurg. 1986;57(8):510–3.PubMed Lunstedt B, Knoop M, Thiede A. Review of the physical and surgical technical properties of modern monofilament suture materials. Chirurg. 1986;57(8):510–3.PubMed
9.
go back to reference Metz SA, Chegini N, Masterson BJ. In vivo and in vitro degradation of monofilament absorbable sutures, PDS and Maxon. Biomaterials. 1990;11(1):41–5.CrossRefPubMed Metz SA, Chegini N, Masterson BJ. In vivo and in vitro degradation of monofilament absorbable sutures, PDS and Maxon. Biomaterials. 1990;11(1):41–5.CrossRefPubMed
10.
go back to reference Sugimachi K, Sufian S, Weiss MJ, Pavlides CA, Matsumoto T. Evaluation of absorbable suture materials in biliary tract surgery. Int Surg. 1978;63(3):135–9.PubMed Sugimachi K, Sufian S, Weiss MJ, Pavlides CA, Matsumoto T. Evaluation of absorbable suture materials in biliary tract surgery. Int Surg. 1978;63(3):135–9.PubMed
11.
go back to reference Barber FA, Herbert MA, Richards DP. Sutures and suture anchors: update 2003. Arthroscopy. 2003;19(9):985–90.CrossRefPubMed Barber FA, Herbert MA, Richards DP. Sutures and suture anchors: update 2003. Arthroscopy. 2003;19(9):985–90.CrossRefPubMed
14.
go back to reference Najibi S, Banglmeier R, Matta J, Tannast M. Material properties of common suture materials in orthopaedic surgery. Iowa Orthop J. 2010;30:84–8.PubMedPubMedCentral Najibi S, Banglmeier R, Matta J, Tannast M. Material properties of common suture materials in orthopaedic surgery. Iowa Orthop J. 2010;30:84–8.PubMedPubMedCentral
17.
go back to reference 1635-04 AF (ed) (2004) A standard test method for in vitro degeneration testing of hydrolytically degradable polymer resins and fabricated forms for surgical implants. Annual Book of ASTM Standards, Philadelphia. 1635-04 AF (ed) (2004) A standard test method for in vitro degeneration testing of hydrolytically degradable polymer resins and fabricated forms for surgical implants. Annual Book of ASTM Standards, Philadelphia.
18.
go back to reference Dinopoulos HT, Boyer MI, Burns ME, Gelberman RH, Silva MJ. The resistance of a four- and eight-strand suture technique to gap formation during tensile testing: an experimental study of repaired canine flexor tendons after 10 days of in vivo healing. J Hand Surg Am. 2000;25(3):489–98. doi:10.1053/jhsu.2000.6456.CrossRefPubMed Dinopoulos HT, Boyer MI, Burns ME, Gelberman RH, Silva MJ. The resistance of a four- and eight-strand suture technique to gap formation during tensile testing: an experimental study of repaired canine flexor tendons after 10 days of in vivo healing. J Hand Surg Am. 2000;25(3):489–98. doi:10.​1053/​jhsu.​2000.​6456.CrossRefPubMed
Metadata
Title
Two-month longitudinal study of mechanical properties of absorbable sutures used in orthopedic surgery
Authors
Daniel A Müller
Jess G Snedeker
Dominik C Meyer
Publication date
01-12-2016
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2016
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/s13018-016-0451-5

Other articles of this Issue 1/2016

Journal of Orthopaedic Surgery and Research 1/2016 Go to the issue