Skip to main content
Top
Published in: Journal of Orthopaedic Surgery and Research 1/2009

Open Access 01-12-2009 | Research article

Two levels above and one level below pedicle screw fixation for the treatment of unstable thoracolumbar fracture with partial or intact neurology

Authors: Hitesh N Modi, Kook Jin Chung, Il Woo Seo, Hoi Soo Yoon, Ji Hyo Hwang, Hong Kyun Kim, Kyu Cheol Noh, Jung Han Yoo

Published in: Journal of Orthopaedic Surgery and Research | Issue 1/2009

Login to get access

Abstract

Background

Treatment of unstable thoracolumbar fractures is controversial regarding short or long segment pedicle screw fixation. Although long level fixation is better, it can decrease one motion segment distally, thus increasing load to lower discs.

Methods

We retrospectively analyzed 31 unstable thoracolumbar fractures with partial or intact neurology. All patients were operated with posterior approach using pedicle screws fixed two levels above and one level below the fracture vertebra. No laminectomy, discectomy or decompression procedure was done. Posterior fusion was achieved in all. Post operative and at final follow-up radiological evaluation was done by measuring the correction and maintenance of kyphotic angle at thoracolumbar junction. Complications were also reported including implant failure.

Results

Average follow-up was 34 months. All patients had full recovery at final follow-up. Average kyphosis was improved from 26.7° to 4.1° postoperatively and to 6.3° at final follow-up. And mean pain scale was improved from 7.5 to 3.9 postoperatively and to 1.6 at final follow-up, All patients resumed their activity within six months. Only 4 (12%) complications were noted including only one hardware failure.

Conclusion

Two levels above and one level below pedicle screw fixation in unstable thoracolumbar burst fracture is useful to prevent progressive kyphosis and preserves one motion segment distally.
Appendix
Available only for authorised users
Literature
1.
go back to reference Yue JJ, Sossan A, Selgrath C, Deutsch LS, Wilkens K, Testaiuti M, Gabriel JP: The treatment of unstable thoracic spine fractures with transpedicular screw instrumentation: a 3-year consecutive series. Spine. 2002, 27 (24): 2782-2787. 10.1097/00007632-200212150-00008.CrossRefPubMed Yue JJ, Sossan A, Selgrath C, Deutsch LS, Wilkens K, Testaiuti M, Gabriel JP: The treatment of unstable thoracic spine fractures with transpedicular screw instrumentation: a 3-year consecutive series. Spine. 2002, 27 (24): 2782-2787. 10.1097/00007632-200212150-00008.CrossRefPubMed
2.
go back to reference Danisa OA, Shaffrey CI, Jane JA, Whitehill R, Wang GJ, Szabo TA, Hansen CA, Shaffrey ME, Chan DP: Surgical approaches for the correction of unstable thoracolumbar burst fractures: a retrospective analysis of treatment outcomes. J Neurosurg. 1995, 83: 977-83. 10.3171/jns.1995.83.6.0977.CrossRefPubMed Danisa OA, Shaffrey CI, Jane JA, Whitehill R, Wang GJ, Szabo TA, Hansen CA, Shaffrey ME, Chan DP: Surgical approaches for the correction of unstable thoracolumbar burst fractures: a retrospective analysis of treatment outcomes. J Neurosurg. 1995, 83: 977-83. 10.3171/jns.1995.83.6.0977.CrossRefPubMed
3.
go back to reference Kaneda K, Taneichi H, Abumi K, Hashimoto T, Satoh S, Fujiya M: Anterior decompression and stabilization with the Kaneda device for thoracolumbar burst fractures associated with neurological deficits. J Bone Joint Surg Am. 1997, 79: 69-83.PubMed Kaneda K, Taneichi H, Abumi K, Hashimoto T, Satoh S, Fujiya M: Anterior decompression and stabilization with the Kaneda device for thoracolumbar burst fractures associated with neurological deficits. J Bone Joint Surg Am. 1997, 79: 69-83.PubMed
4.
go back to reference Carl AL, Tromanhauser SG, Roger DL: Pedicle screw instrumentation for thoracolumbar burst fractures and fracture-dislocation. Spine. 1992, 17: S317-324. 10.1097/00007632-199208001-00018.CrossRefPubMed Carl AL, Tromanhauser SG, Roger DL: Pedicle screw instrumentation for thoracolumbar burst fractures and fracture-dislocation. Spine. 1992, 17: S317-324. 10.1097/00007632-199208001-00018.CrossRefPubMed
5.
go back to reference Roy-Camille R, Saillant G, Mazel C: Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop. 1986, 203: 7-17.PubMed Roy-Camille R, Saillant G, Mazel C: Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop. 1986, 203: 7-17.PubMed
6.
go back to reference Korovessis P, Baikousis A, Stamatakis M: Use of the Texas Scottish Rite Hospital Instrumentation in the treatment of thoracolumbar injuries. Spine. 1997, 22: 882-888. 10.1097/00007632-199704150-00011.CrossRefPubMed Korovessis P, Baikousis A, Stamatakis M: Use of the Texas Scottish Rite Hospital Instrumentation in the treatment of thoracolumbar injuries. Spine. 1997, 22: 882-888. 10.1097/00007632-199704150-00011.CrossRefPubMed
7.
go back to reference Dick W, Kluger P, Magerl F, Woersdorfer O, Zach G: A new device for internal fixation of thoracolumbar and lumbar spine fractures: the fixateur interne. Paraplegia. 1985, 23: 225-232.CrossRefPubMed Dick W, Kluger P, Magerl F, Woersdorfer O, Zach G: A new device for internal fixation of thoracolumbar and lumbar spine fractures: the fixateur interne. Paraplegia. 1985, 23: 225-232.CrossRefPubMed
8.
go back to reference Nagel DA, Koogle TA, Piziali RL, Perkash I: Stability of upper lumbar spine following progressive disruption and the application of individual internal and external devices. J Bone Joint Surg Am. 1981, 63: 62-70.PubMed Nagel DA, Koogle TA, Piziali RL, Perkash I: Stability of upper lumbar spine following progressive disruption and the application of individual internal and external devices. J Bone Joint Surg Am. 1981, 63: 62-70.PubMed
9.
go back to reference Haher TR, Bergman M, O'Brien M, Felmly WT, Choueka J, Welin D, Chow G, Vassiliou A: The effect of three column of spine on the instantaneous axis of rotation in flexion and extension. Spine. 1991, 16: S312-318. 10.1097/00007632-199108001-00001.CrossRefPubMed Haher TR, Bergman M, O'Brien M, Felmly WT, Choueka J, Welin D, Chow G, Vassiliou A: The effect of three column of spine on the instantaneous axis of rotation in flexion and extension. Spine. 1991, 16: S312-318. 10.1097/00007632-199108001-00001.CrossRefPubMed
10.
go back to reference Gurr KR, McAfee PC, Shih CM: Biomechanical analysis of anterior and posterior instrumentation systems after corpectomy: A calf-spine model. J Bone Joint Surg Am. 1988, 70: 1182-91.PubMed Gurr KR, McAfee PC, Shih CM: Biomechanical analysis of anterior and posterior instrumentation systems after corpectomy: A calf-spine model. J Bone Joint Surg Am. 1988, 70: 1182-91.PubMed
11.
go back to reference Krag MH: Biomechanics of thoracolumbar spinal fixation: A review. Spine. 1991, 16: S84-99. 10.1097/00007632-199103001-00014.CrossRefPubMed Krag MH: Biomechanics of thoracolumbar spinal fixation: A review. Spine. 1991, 16: S84-99. 10.1097/00007632-199103001-00014.CrossRefPubMed
12.
go back to reference McAfee PC, Yuan HA, Fredrickson BE, Lubicky JP: The value of computed tomography in thoracolumbar fractures. An analysis of one hundred consecutive cases and a new classification. J Bone Joint Surg Am. 1983, 65: 461-473.PubMed McAfee PC, Yuan HA, Fredrickson BE, Lubicky JP: The value of computed tomography in thoracolumbar fractures. An analysis of one hundred consecutive cases and a new classification. J Bone Joint Surg Am. 1983, 65: 461-473.PubMed
13.
go back to reference Boucher HH: A method of spinal fusion. J Bone Joint Surg Br. 1959, 41: 248-259.PubMed Boucher HH: A method of spinal fusion. J Bone Joint Surg Br. 1959, 41: 248-259.PubMed
14.
go back to reference Akbarnia BA, Crandall DG, Burkus K, Matthews T: Use of long rods and a short arthrodesis for burst fractures of the thoracolumbar spine. A long-term follow-up study. J Bone Joint Surg Am. 1994, 76 (11): 1629-1635.PubMed Akbarnia BA, Crandall DG, Burkus K, Matthews T: Use of long rods and a short arthrodesis for burst fractures of the thoracolumbar spine. A long-term follow-up study. J Bone Joint Surg Am. 1994, 76 (11): 1629-1635.PubMed
15.
go back to reference Knop C, Bastian L, Lange U, Oeser M, Zdichavsky M, Blauth M: Complications in surgical treatment of thoracolumbar injuries. Eur Spine J. 2002, 11 (3): 214-226. 10.1007/s00586-001-0382-6.PubMedCentralCrossRefPubMed Knop C, Bastian L, Lange U, Oeser M, Zdichavsky M, Blauth M: Complications in surgical treatment of thoracolumbar injuries. Eur Spine J. 2002, 11 (3): 214-226. 10.1007/s00586-001-0382-6.PubMedCentralCrossRefPubMed
16.
go back to reference Li KC, Hsieh CH, Lee CY, Chen TH: Transpedicle body augmenter: a further step in treating burst fractures. Clin Orthop Relat Res. 2005, 436: 119-125. 10.1097/01.blo.0000158316.89886.63.CrossRefPubMed Li KC, Hsieh CH, Lee CY, Chen TH: Transpedicle body augmenter: a further step in treating burst fractures. Clin Orthop Relat Res. 2005, 436: 119-125. 10.1097/01.blo.0000158316.89886.63.CrossRefPubMed
17.
go back to reference Parker JW, Lane JR, Karaikovic EE, Gaines RW: Successful short-segment instrumentation and fusion for thoracolumbar spine fractures: a consecutive 4 1/2-year series. Spine. 2000, 25 (9): 1157-1170. 10.1097/00007632-200005010-00018.CrossRefPubMed Parker JW, Lane JR, Karaikovic EE, Gaines RW: Successful short-segment instrumentation and fusion for thoracolumbar spine fractures: a consecutive 4 1/2-year series. Spine. 2000, 25 (9): 1157-1170. 10.1097/00007632-200005010-00018.CrossRefPubMed
18.
go back to reference Alanay A, Acarolu E, Yazici M, Oznur A, Surat A: Short-segment pedicle instrumentation of thoracolumbar burst fractures: does transpedicular intracorporeal grafting prevent early failure. Spine. 2001, 26 (2): 213-217. 10.1097/00007632-200101150-00017.CrossRefPubMed Alanay A, Acarolu E, Yazici M, Oznur A, Surat A: Short-segment pedicle instrumentation of thoracolumbar burst fractures: does transpedicular intracorporeal grafting prevent early failure. Spine. 2001, 26 (2): 213-217. 10.1097/00007632-200101150-00017.CrossRefPubMed
19.
go back to reference McLain RF, Sparling E, Benson DR: Early failure of short-segment pedicle instrumentation of thoracolumbar fractures. A preliminary report. J Bone Joint Surg Am. 1993, 75 (2): 162-167.PubMed McLain RF, Sparling E, Benson DR: Early failure of short-segment pedicle instrumentation of thoracolumbar fractures. A preliminary report. J Bone Joint Surg Am. 1993, 75 (2): 162-167.PubMed
20.
go back to reference De Peretti F, Hovorka I, Cambas PM, Nasr JM, Argenson C: Short device fixation and early mobilization for burst fractures of the thoracolumbar junction. Eur Spine J. 1996, 5: 112-120. 10.1007/BF00298390.CrossRefPubMed De Peretti F, Hovorka I, Cambas PM, Nasr JM, Argenson C: Short device fixation and early mobilization for burst fractures of the thoracolumbar junction. Eur Spine J. 1996, 5: 112-120. 10.1007/BF00298390.CrossRefPubMed
21.
go back to reference Cho DY, Lee WY, Sheu PC: Treatment of thoracolumbar burst fractures with polymethyl methacrylate vertebroplasty and short-segment pedicle screw fixation. Neurosurgery. 2003, 53 (6): 1354-1360. 10.1227/01.NEU.0000093200.74828.2F.CrossRefPubMed Cho DY, Lee WY, Sheu PC: Treatment of thoracolumbar burst fractures with polymethyl methacrylate vertebroplasty and short-segment pedicle screw fixation. Neurosurgery. 2003, 53 (6): 1354-1360. 10.1227/01.NEU.0000093200.74828.2F.CrossRefPubMed
22.
go back to reference Gurr KR, McAfee PC: Cotrel-Dubousset instrumentation in adults. A preliminary report. Spine. 1988, 13: 510-520. 10.1097/00007632-198805000-00014.CrossRefPubMed Gurr KR, McAfee PC: Cotrel-Dubousset instrumentation in adults. A preliminary report. Spine. 1988, 13: 510-520. 10.1097/00007632-198805000-00014.CrossRefPubMed
23.
go back to reference Rommens PM, Weyns F, Van Calenbergh F, Goffin J, Broos PL: Mechanical performance of the Dick internal fixator. A clinical study of 75 patients. Eur Spine J. 1995, 4: 104-109. 10.1007/BF00278921.CrossRefPubMed Rommens PM, Weyns F, Van Calenbergh F, Goffin J, Broos PL: Mechanical performance of the Dick internal fixator. A clinical study of 75 patients. Eur Spine J. 1995, 4: 104-109. 10.1007/BF00278921.CrossRefPubMed
24.
go back to reference Altay M, Ozkurt B, Aktekin CN, Ozturk AM, Dogan O, Tabak AY: Treatment of unstable thoracolumbar junction burst fractures with short- or long- segment posterior fixation in magrel type a fractures. Eur Spine J. 2007, 16: 1145-1155. 10.1007/s00586-007-0310-5.PubMedCentralCrossRefPubMed Altay M, Ozkurt B, Aktekin CN, Ozturk AM, Dogan O, Tabak AY: Treatment of unstable thoracolumbar junction burst fractures with short- or long- segment posterior fixation in magrel type a fractures. Eur Spine J. 2007, 16: 1145-1155. 10.1007/s00586-007-0310-5.PubMedCentralCrossRefPubMed
25.
go back to reference Tezeren G, Kuru I: Posterior fixation of thoracolumbar burst fracture. Short-segment pedicle fixation versus long-segment instrumentation. J Spinal Disord Tech. 2005, 18: 485-488. 10.1097/01.bsd.0000149874.61397.38.CrossRefPubMed Tezeren G, Kuru I: Posterior fixation of thoracolumbar burst fracture. Short-segment pedicle fixation versus long-segment instrumentation. J Spinal Disord Tech. 2005, 18: 485-488. 10.1097/01.bsd.0000149874.61397.38.CrossRefPubMed
26.
go back to reference Butt MF, Farooq M, Mir B, Dhar AS, Hussain A, Mumtaz M: Management of unstable thoracolumbar spinal injuries by short segment pinal fixation. International Orthop. 2007, 31: 259-264. 10.1007/s00264-006-0161-4.CrossRef Butt MF, Farooq M, Mir B, Dhar AS, Hussain A, Mumtaz M: Management of unstable thoracolumbar spinal injuries by short segment pinal fixation. International Orthop. 2007, 31: 259-264. 10.1007/s00264-006-0161-4.CrossRef
Metadata
Title
Two levels above and one level below pedicle screw fixation for the treatment of unstable thoracolumbar fracture with partial or intact neurology
Authors
Hitesh N Modi
Kook Jin Chung
Il Woo Seo
Hoi Soo Yoon
Ji Hyo Hwang
Hong Kyun Kim
Kyu Cheol Noh
Jung Han Yoo
Publication date
01-12-2009
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2009
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/1749-799X-4-28

Other articles of this Issue 1/2009

Journal of Orthopaedic Surgery and Research 1/2009 Go to the issue