Abstract

Background

Developed for the treatment of deformity correction, computer-assisted circular external fixators in recent years have also been used for fracture fixation. In this study, we aimed to present the efficacy of computer-assisted circular external fixator use in open long bone fractures with our new technique.

Methods

Between February 2013 and June 2014, 14 patients (mean age 24.5 (range 20–32)) with open tibial or femoral open fractures were treated with the computer-assisted fixation system (Spider Frame-Tasarım Medikal, Istanbul, Turkey). In all patients, appropriate positions of the rings and Schanz screws were determined by measurements on preoperative radiographs. The length of the Schanz screws were determined by depth measure marks on drill bits. Obvious deformities were corrected intraoperatively by manipulations, but residual deformities were corrected by a software program (Spiderfix, Tasarım Medikal, Istanbul, Turkey). We did not use fluoroscopy during the procedures.

Results

Ten patients had tibia diaphyseal and four patients had femoral diaphyseal fractures. Mean surgical time was 24.2 (range 18–28) min. Average follow-up time was 10.2 (range 9–14) months. Mean time for deformity correction was 3.1 (2–5) days. Complete union was observed in all patients with a mean of 4.9 (range 3–9) months. There were two grade 2 pin site infections treated with oral antibiotherapy and pin site care. We did not detect any Schanz screw breakage, loosening, deep infection, nonunion, or malunion.

Conclusions

Computer-assisted external fixation systems can be used in the treatment of open fractures, and they provide the chance for acute or gradual correction. Preoperative planning and assistant devices with depth measures may decrease the procedure time and the need for fluoroscopy use.
Literature
1.
go back to reference Zalavras CG, Marcus RE, Levin LS, Patzakis MJ. Management of open fractures and subsequent complications. J Bone Joint Surg Am. 2007;89(4):884–95.PubMed Zalavras CG, Marcus RE, Levin LS, Patzakis MJ. Management of open fractures and subsequent complications. J Bone Joint Surg Am. 2007;89(4):884–95.PubMed
2.
go back to reference Inan M, Tuncel M, Karaoglu S, Halici M. Treatment of type II and III open tibial fractures with Ilizarov external fixation. Acta Orthop Traumatol Turc. 2002;36(5):390–6.PubMed Inan M, Tuncel M, Karaoglu S, Halici M. Treatment of type II and III open tibial fractures with Ilizarov external fixation. Acta Orthop Traumatol Turc. 2002;36(5):390–6.PubMed
4.
go back to reference Paley D, Chaudray M, Pirone AM, Lentz P, Kautz D. Treatment of malunions and mal-nonunions of the femur and tibia by detailed preoperative planning and the Ilizarov techniques. Orthop Clin North Am. 1990;21(4):667–91.PubMed Paley D, Chaudray M, Pirone AM, Lentz P, Kautz D. Treatment of malunions and mal-nonunions of the femur and tibia by detailed preoperative planning and the Ilizarov techniques. Orthop Clin North Am. 1990;21(4):667–91.PubMed
7.
go back to reference Binski JC. Taylor spatial frame in acute fracture care. Tech Orthop 2002;17(2)173-84. Binski JC. Taylor spatial frame in acute fracture care. Tech Orthop 2002;17(2)173-84.
9.
go back to reference Gustilo RB, Anderson JT. Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones: retrospective and prospective analyses. J Bone Joint Surg Am. 1976;58(4):453–8.PubMed Gustilo RB, Anderson JT. Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones: retrospective and prospective analyses. J Bone Joint Surg Am. 1976;58(4):453–8.PubMed
10.
go back to reference Paley D. Problems, obstacles, and complications of limb lengthening by the Ilizarov technique. Clin Orthop Relat Res. 1990;250:81–104.PubMed Paley D. Problems, obstacles, and complications of limb lengthening by the Ilizarov technique. Clin Orthop Relat Res. 1990;250:81–104.PubMed
11.
go back to reference Behrens F, Searls K. External fixation of the tibia. Basic concepts and prospective evaluation. J Bone Joint Surg Br Vol. 1986;68(2):246–54. Behrens F, Searls K. External fixation of the tibia. Basic concepts and prospective evaluation. J Bone Joint Surg Br Vol. 1986;68(2):246–54.
12.
go back to reference Tornetta 3rd P, Bergman M, Watnik N, Berkowitz G, Steuer J. Treatment of grade-IIIb open tibial fractures. A prospective randomised comparison of external fixation and non-reamed locked nailing. J Bone Joint Surg Br Vol. 1994;76(1):13–9. Tornetta 3rd P, Bergman M, Watnik N, Berkowitz G, Steuer J. Treatment of grade-IIIb open tibial fractures. A prospective randomised comparison of external fixation and non-reamed locked nailing. J Bone Joint Surg Br Vol. 1994;76(1):13–9.
16.
go back to reference Sanders R, Koval KJ, DiPasquale T, Schmelling G, Stenzler S, Ross E. Exposure of the orthopaedic surgeon to radiation. J Bone Joint Surg Am. 1993;75(3):326–30.PubMed Sanders R, Koval KJ, DiPasquale T, Schmelling G, Stenzler S, Ross E. Exposure of the orthopaedic surgeon to radiation. J Bone Joint Surg Am. 1993;75(3):326–30.PubMed
17.
go back to reference Mastrangelo G, Fedeli U, Fadda E, Giovanazzi A, Scoizzato L, Saia B. Increased cancer risk among surgeons in an orthopaedic hospital. Occup Med (Oxford, England). 2005;55(6):498–500. doi:10.1093/occmed/kqi048.CrossRef Mastrangelo G, Fedeli U, Fadda E, Giovanazzi A, Scoizzato L, Saia B. Increased cancer risk among surgeons in an orthopaedic hospital. Occup Med (Oxford, England). 2005;55(6):498–500. doi:10.​1093/​occmed/​kqi048.CrossRef
Metadata
Title
Treatment of open fractures with a computer-assisted external fixator system without the use of fluoroscopy
Authors
Adnan Kara
Haluk Celik
Ali Seker
Ozgur Karakoyun
Raffi Armagan
Ersin Kuyucu
Mehmet Erdil
Publication date
01-12-2016
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2016
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/s13018-016-0379-9

Other articles of this Issue 1/2016

Journal of Orthopaedic Surgery and Research 1/2016 Go to the issue