Abstract

Introduction

Neer type II lateral clavicle fractures are inherently unstable and debate continues regarding optimal treatment. The purpose of this study was to review the outcome of Neer type II lateral clavicle fractures treated using a novel technique, which incorporates a superiorly placed distal radius locking plate combined with TightRope™ fixation to augment the coraco-clavicular ligaments.

Methods

Between 2007 and 2010, a total of 31 Neer type II fractures were managed operatively at our institution. Clinical outcomes were assessed using the SPADI, DASH, Constant, and Taft scores. Subjects were evaluated at 6 weeks, 3, 6 months, and 1 year. For the latest follow-up (mean 38.7 months), all patients were telephoned by an independent research associate and interviewed to establish SPADI and DASH scores. Radiological union was evaluated using standard views including an antero-posterior view, an angled (Zanca) view, and a trans-scapular view.

Results

Bony union was achieved at a mean follow-up of 6.3 ± 4.1 weeks. At the 1-year follow-up, the AC joint remained reduced radiologically in all cases. At 1 year, the mean Constant score was 95.6 ± 4.82, the DASH score was 3.45 ± 3.02, and the SPADI score was 2.58 + 1.94. At the latest follow-up, at a mean of 38.7 + 14.8 months, the DASH score was 0.6 ± 2.1 and the SPADI score was 0.6 ± 2.

Conclusion

Surgical fixation of Neer type II lateral clavicle fractures using a 2.4-mm distal radius locking plate in combination with TightRope™ suture augmentation results in a predictable outcome, preserving excellent shoulder function while maintaining a low complication rate.
Literature
1.
go back to reference Neer CS (1984) Fractures and dislocations of the shoulder. In: Rockwood Jr. CA, Green DP (eds) Fractures in adults, Philadelphia: J. B. Lippincott, Philadelphia, pp 711–712. ISBN: 0397506236 Neer CS (1984) Fractures and dislocations of the shoulder. In: Rockwood Jr. CA, Green DP (eds) Fractures in adults, Philadelphia: J. B. Lippincott, Philadelphia, pp 711–712. ISBN: 0397506236
2.
go back to reference Anderson K (2003) Evaluation and treatment of distal clavicle fractures. Clin Sports Med 22:319–326PubMedCrossRef Anderson K (2003) Evaluation and treatment of distal clavicle fractures. Clin Sports Med 22:319–326PubMedCrossRef
3.
go back to reference Cheng ZJ, Hyun-Kim K, Byoung-Hyun M (2006) Surgical treatment for distal clavicle fracture associated with coracoclavicular ligament rupture using a cannulated screw fixation technique. J Trauma 60:1358–1361CrossRef Cheng ZJ, Hyun-Kim K, Byoung-Hyun M (2006) Surgical treatment for distal clavicle fracture associated with coracoclavicular ligament rupture using a cannulated screw fixation technique. J Trauma 60:1358–1361CrossRef
4.
go back to reference Jerosch J, Filler T, Peuker E, Greig M, Siewering U (1999) Which stabilization technique corrects anatomy best in patients with AC separation? An experimental study. Knee Surg Sports Traumatol Arthrosc 7:365–372PubMedCrossRef Jerosch J, Filler T, Peuker E, Greig M, Siewering U (1999) Which stabilization technique corrects anatomy best in patients with AC separation? An experimental study. Knee Surg Sports Traumatol Arthrosc 7:365–372PubMedCrossRef
5.
go back to reference Edwards DJ, Kavanagh TG, Flannery MC (1992) Fractures of the distal clavicle: a case for fixation. Injury 23:44–46PubMedCrossRef Edwards DJ, Kavanagh TG, Flannery MC (1992) Fractures of the distal clavicle: a case for fixation. Injury 23:44–46PubMedCrossRef
6.
go back to reference Shin SJ, Roh KJ, Kim JO, Sohn HS (2009) Treatment of unstable distal clavicle fractures using two suture anchors and suture tension bands. Injury 40:1308–1312PubMedCrossRef Shin SJ, Roh KJ, Kim JO, Sohn HS (2009) Treatment of unstable distal clavicle fractures using two suture anchors and suture tension bands. Injury 40:1308–1312PubMedCrossRef
7.
go back to reference Herrmann S, Schmidmaier S, Greiner S (2008) Stabilisation of vertical unstable distal clavicular fractures (Neer 2b) using locking T-plates and suture anchors. Injury 40:236–239CrossRef Herrmann S, Schmidmaier S, Greiner S (2008) Stabilisation of vertical unstable distal clavicular fractures (Neer 2b) using locking T-plates and suture anchors. Injury 40:236–239CrossRef
8.
go back to reference Kalamares M, Cutbush K, Robinson M (2008) A method for internal fixation of unstable distal clavicle fractures: early observations using a new technique. J Should Elb Surg 17:60–62CrossRef Kalamares M, Cutbush K, Robinson M (2008) A method for internal fixation of unstable distal clavicle fractures: early observations using a new technique. J Should Elb Surg 17:60–62CrossRef
9.
go back to reference Wang SJ, Wong CS (2008) Extra-articular Knowles pin fixation for unstable distal clavicle fractures. J Trauma 64:1522–1527PubMedCrossRef Wang SJ, Wong CS (2008) Extra-articular Knowles pin fixation for unstable distal clavicle fractures. J Trauma 64:1522–1527PubMedCrossRef
10.
go back to reference Yoo JH, Chang JD, Seo YS, Shin JH (2008) Stable fixation of distal clavicle fracture with comminuted superior cortex using oblique T-plate and cerclage wiring. Injury 40:455–457PubMedCrossRef Yoo JH, Chang JD, Seo YS, Shin JH (2008) Stable fixation of distal clavicle fracture with comminuted superior cortex using oblique T-plate and cerclage wiring. Injury 40:455–457PubMedCrossRef
11.
12.
go back to reference Badhe SP, Lawrence TM, Clark DI (2007) Tension band suturing for the treatment of displaced type 2 lateral end clavicle fractures. Arch Orthop Trauma Surg 127:25–28PubMedCrossRef Badhe SP, Lawrence TM, Clark DI (2007) Tension band suturing for the treatment of displaced type 2 lateral end clavicle fractures. Arch Orthop Trauma Surg 127:25–28PubMedCrossRef
13.
go back to reference Lee YS, Lau MJ, Tseng YC, Chen WC, Kao HY, Wei JD (2009) Comparison of hook plate versus tension band wire in the treatment of unstable fractures of the distal clavicle. Int Orthop (SICOT) 33:1401–1405CrossRef Lee YS, Lau MJ, Tseng YC, Chen WC, Kao HY, Wei JD (2009) Comparison of hook plate versus tension band wire in the treatment of unstable fractures of the distal clavicle. Int Orthop (SICOT) 33:1401–1405CrossRef
14.
go back to reference Mall JW, Jacobi CA, Philipp AW, Peter FJ (2002) Surgical treatment of fractures of the distal clavicle with polydioxane suture tension band wiring: an alternative osteosynthesis. J Orthop Sci 7:535–537PubMedCrossRef Mall JW, Jacobi CA, Philipp AW, Peter FJ (2002) Surgical treatment of fractures of the distal clavicle with polydioxane suture tension band wiring: an alternative osteosynthesis. J Orthop Sci 7:535–537PubMedCrossRef
15.
go back to reference Flinkkilä T, Ristiniemi J, Hyvönen P, Hammleinen M (2002) Surgical treatment of unstable fractures of the distal clavicle: a comparative study of Kirschner wire and clavicular hook plate fixation. Acta Orthop Scand 73:50–53PubMedCrossRef Flinkkilä T, Ristiniemi J, Hyvönen P, Hammleinen M (2002) Surgical treatment of unstable fractures of the distal clavicle: a comparative study of Kirschner wire and clavicular hook plate fixation. Acta Orthop Scand 73:50–53PubMedCrossRef
16.
go back to reference Flinkkilä T, Ristiniemi J, Lakovaara M, Hyvönen P, Leppilahti J (2006) Hook-plate fixation of unstable lateral clavicle fractures. A report on 63 patients. Acta Orthop Scand 77:644–649CrossRef Flinkkilä T, Ristiniemi J, Lakovaara M, Hyvönen P, Leppilahti J (2006) Hook-plate fixation of unstable lateral clavicle fractures. A report on 63 patients. Acta Orthop Scand 77:644–649CrossRef
17.
go back to reference Jou IM, Chiang EP, Lin CJ, Cheng LL, Wang PH, Su WR (2011) Treatment of unstable distal clavicle fractures with Knowles pin. J Should Elb Surg 20:414–419CrossRef Jou IM, Chiang EP, Lin CJ, Cheng LL, Wang PH, Su WR (2011) Treatment of unstable distal clavicle fractures with Knowles pin. J Should Elb Surg 20:414–419CrossRef
18.
go back to reference Robinson CM, Akhtar MA, Jenkins PJ, Sharpe T, Ray A, Olabi B (2010) Open reduction and endobutton fixation of displaced fractures of the lateral end of the clavicle in younger patients. J Bone Joint Surg [Br] 22:811–816 Robinson CM, Akhtar MA, Jenkins PJ, Sharpe T, Ray A, Olabi B (2010) Open reduction and endobutton fixation of displaced fractures of the lateral end of the clavicle in younger patients. J Bone Joint Surg [Br] 22:811–816
19.
go back to reference Kaipel M, Majewski M, Regazzoni P (2010) Double-plate fixation in lateral clavicle fractures—a new strategy. J Trauma 69:896–900PubMedCrossRef Kaipel M, Majewski M, Regazzoni P (2010) Double-plate fixation in lateral clavicle fractures—a new strategy. J Trauma 69:896–900PubMedCrossRef
20.
go back to reference Checchia SL, Doneux PS, Miyasaki AN, Fregoneze M, Silva LA (2008) Treatment of distal clavicle fractures using an arthroscopic technique. J Should Elb Surg 17:395–398CrossRef Checchia SL, Doneux PS, Miyasaki AN, Fregoneze M, Silva LA (2008) Treatment of distal clavicle fractures using an arthroscopic technique. J Should Elb Surg 17:395–398CrossRef
21.
go back to reference Nourissat G, Kakuda C, Dumontier C, Sautet A, Dourssounia L (2007) Arthroscopic stabilization of Neer type 2 fractures of the distal part of the clavicle. Arthroscopy 23:674e1–674e4 Nourissat G, Kakuda C, Dumontier C, Sautet A, Dourssounia L (2007) Arthroscopic stabilization of Neer type 2 fractures of the distal part of the clavicle. Arthroscopy 23:674e1–674e4
22.
go back to reference Pujol N, Philippeau JM, Richou J, Lespangnol F, Graveleau, Hardy P (2008) Arthroscopic treatment of distal clavicle fractures: a technical note. Knee Surg Sports Traumatol Arthrosc 16:884–886PubMedCrossRef Pujol N, Philippeau JM, Richou J, Lespangnol F, Graveleau, Hardy P (2008) Arthroscopic treatment of distal clavicle fractures: a technical note. Knee Surg Sports Traumatol Arthrosc 16:884–886PubMedCrossRef
23.
go back to reference Clark RL, Milgram JW, Yawn DH (1974) Fatal aortic perforation and cardiac tamponade due to a Kirschner wire migrating from the right sternoclavicular joint. South Med J 67:316–318PubMedCrossRef Clark RL, Milgram JW, Yawn DH (1974) Fatal aortic perforation and cardiac tamponade due to a Kirschner wire migrating from the right sternoclavicular joint. South Med J 67:316–318PubMedCrossRef
24.
go back to reference Yu C, Sun YH, Zhao CQ, Shi DW, Wang Y (2009) Treatment of distal clavicle fracture with distal radius volar locking compression plate. Chin J Traumatol 12:299–301PubMed Yu C, Sun YH, Zhao CQ, Shi DW, Wang Y (2009) Treatment of distal clavicle fracture with distal radius volar locking compression plate. Chin J Traumatol 12:299–301PubMed
25.
go back to reference Constant MR, Murley AH (1987) A clinical method of functional assessment of the shoulder. Clin Orth Relat Res 214:160–164 Constant MR, Murley AH (1987) A clinical method of functional assessment of the shoulder. Clin Orth Relat Res 214:160–164
26.
go back to reference Gummesson C, Atroshi I, Ekdahl C (2003) The Disabilities of the Arm, Shoulder and Hand (DASH) outcome questionnaire: longitudinal construct validity and measuring self-rated health change after surgery. BMC Musculoskelet Disord 16:11CrossRef Gummesson C, Atroshi I, Ekdahl C (2003) The Disabilities of the Arm, Shoulder and Hand (DASH) outcome questionnaire: longitudinal construct validity and measuring self-rated health change after surgery. BMC Musculoskelet Disord 16:11CrossRef
27.
go back to reference Hill CL, Lester S, Taylor AW, Shanahan ME, Gill TK (2011) Factor structure and validity of the shoulder pain and disability index in a population-based study of people with shoulder symptoms. BMC Musculoskelet Disord 12:8PubMedCrossRef Hill CL, Lester S, Taylor AW, Shanahan ME, Gill TK (2011) Factor structure and validity of the shoulder pain and disability index in a population-based study of people with shoulder symptoms. BMC Musculoskelet Disord 12:8PubMedCrossRef
28.
go back to reference Taft TN, Wilson FC, Oglesby JW (1987) Dislocation of the acromioclavicular joint. J Bone Joint Am 69A:1045–1051 Taft TN, Wilson FC, Oglesby JW (1987) Dislocation of the acromioclavicular joint. J Bone Joint Am 69A:1045–1051
29.
go back to reference Bossart PJ, Jouce SM, Manaster BJ, Packer SM (1988) Lack of efficacy of “weighted” radiographs in diagnosing acute coracoclavicular separation. Ann Emerg Med 17:20–24PubMedCrossRef Bossart PJ, Jouce SM, Manaster BJ, Packer SM (1988) Lack of efficacy of “weighted” radiographs in diagnosing acute coracoclavicular separation. Ann Emerg Med 17:20–24PubMedCrossRef
30.
go back to reference Yap JJ, Curl LA, Kvitne RS, McFarland EG (1999) The value of weighted views of the acromioclavicular joint. Results of a survey. Am J Sports Med 27:806–809PubMed Yap JJ, Curl LA, Kvitne RS, McFarland EG (1999) The value of weighted views of the acromioclavicular joint. Results of a survey. Am J Sports Med 27:806–809PubMed
31.
go back to reference Mazzocca AD, Spang JT, Rodrigues RR, Rios CG, Romeo AA, Arciero RA (2008) Biomechanical and radiographic analysis of partial coracoclavicular ligament injuries. Am J Sports Med 36:1397–1402PubMedCrossRef Mazzocca AD, Spang JT, Rodrigues RR, Rios CG, Romeo AA, Arciero RA (2008) Biomechanical and radiographic analysis of partial coracoclavicular ligament injuries. Am J Sports Med 36:1397–1402PubMedCrossRef
32.
go back to reference Neer CS (1968) Fractures of the distal third of the clavicle. Clin Orth Relat Res 1968(58):43–50 Neer CS (1968) Fractures of the distal third of the clavicle. Clin Orth Relat Res 1968(58):43–50
33.
go back to reference Renger RJ, Roukema GR, Reurings JC, Raams PM, Font J, Verleisdonk EJ (2009) The clavicle hook plate for Neer type II lateral fractures. J Orthop Trauma 23:570–574PubMedCrossRef Renger RJ, Roukema GR, Reurings JC, Raams PM, Font J, Verleisdonk EJ (2009) The clavicle hook plate for Neer type II lateral fractures. J Orthop Trauma 23:570–574PubMedCrossRef
34.
go back to reference Kona J, Bosse MJ, Staheli JW (1990) Rosseau RL (1990) Type II distal clavicle fractures: a retrospective review of surgical treatment. J Orthop Trauma 4:115–120PubMedCrossRef Kona J, Bosse MJ, Staheli JW (1990) Rosseau RL (1990) Type II distal clavicle fractures: a retrospective review of surgical treatment. J Orthop Trauma 4:115–120PubMedCrossRef
35.
go back to reference Motamedi AR, Blevins FT, Willis MC, McNally TP, Shahinpoor M (2000) Biomechanics of the coracoclavicular ligament complex and augmentations used in its repair and reconstruction. Am J Sports Med 28:380–384PubMed Motamedi AR, Blevins FT, Willis MC, McNally TP, Shahinpoor M (2000) Biomechanics of the coracoclavicular ligament complex and augmentations used in its repair and reconstruction. Am J Sports Med 28:380–384PubMed
36.
go back to reference Walz L, Salzmann GM, Fabbro T, Eichhorn S, Imhoff AB (2008) The anatomic reconstruction of acromioclavicular joint dislocations using 2 TightRope devices: a biomechanical study. Am J Sports Med 36:2398–2406PubMedCrossRef Walz L, Salzmann GM, Fabbro T, Eichhorn S, Imhoff AB (2008) The anatomic reconstruction of acromioclavicular joint dislocations using 2 TightRope devices: a biomechanical study. Am J Sports Med 36:2398–2406PubMedCrossRef
37.
go back to reference Jackson WFM, Bayne G, Gregg-Smith SJ (2006) Fractures of the lateral third of the clavicle: an anatomic approach to treatment. J Trauma 61:222–225PubMedCrossRef Jackson WFM, Bayne G, Gregg-Smith SJ (2006) Fractures of the lateral third of the clavicle: an anatomic approach to treatment. J Trauma 61:222–225PubMedCrossRef
Metadata
Title
Treatment of Neer type II fractures of the lateral clavicle using distal radius locking plates combined with TightRope augmentation of the coraco-clavicular ligaments
Authors
Erik Hohmann
Tracy Hansen
Kevin Tetsworth
Publication date
01-10-2012
Publisher
Springer-Verlag
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 10/2012
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-012-1570-z

Other articles of this Issue 10/2012

Archives of Orthopaedic and Trauma Surgery 10/2012 Go to the issue