Skip to main content
Top
Published in: Neuroradiology 3/2010

01-03-2010 | Interventional Neuroradiology

Treatment of a wide-necked aneurysm of the anterior cerebral artery using two Enterprise stents in “Y”-configuration stenting technique and coil embolization: a technical note

Authors: Stefan Rohde, Martin Bendszus, Marius Hartmann, Stefan Hähnel

Published in: Neuroradiology | Issue 3/2010

Login to get access

Abstract

The endovascular treatment of wide-necked aneurysms remains challenging. The “Y”-stenting technique has been used for stent-assisted coil embolization of wide-necked bifurcation aneurysms. So far, this technique has been described for aneurysms of the basilar apex or the middle cerebral artery bifurcation and only for open stent systems using the Neuroform stent. We report a 52-year-old woman with recurrence of a wide-necked aneurysm of the anterior cerebral artery that was successfully retreated by stent-assisted coiling using the “Y”-stenting technique with the Enterprise stent system.
Literature
1.
go back to reference Akpek S, Arat A, Morsi H, Klucznick RP, Strother CM, Mawad ME (2005) Self-expandable stent-assisted coiling of wide-necked intracranial aneurysms: a single-center experience. AJNR Am J Neuroradiol 26(5):1223–1231PubMed Akpek S, Arat A, Morsi H, Klucznick RP, Strother CM, Mawad ME (2005) Self-expandable stent-assisted coiling of wide-necked intracranial aneurysms: a single-center experience. AJNR Am J Neuroradiol 26(5):1223–1231PubMed
2.
go back to reference Biondi A, Janardhan V, Katz JM, Salvaggio K, Riina HA, Gobin YP (2007) Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: strategies in stent deployment and midterm follow-up. Neurosurgery 61(3):460–468 discussion 468–469CrossRefPubMed Biondi A, Janardhan V, Katz JM, Salvaggio K, Riina HA, Gobin YP (2007) Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: strategies in stent deployment and midterm follow-up. Neurosurgery 61(3):460–468 discussion 468–469CrossRefPubMed
3.
go back to reference Sani S, Lopes DK (2005) Treatment of a middle cerebral artery bifurcation aneurysm using a double neuroform stent “Y” configuration and coil embolization: technical case report. Neurosurgery 57(1 Suppl):E209 discussion E209CrossRefPubMed Sani S, Lopes DK (2005) Treatment of a middle cerebral artery bifurcation aneurysm using a double neuroform stent “Y” configuration and coil embolization: technical case report. Neurosurgery 57(1 Suppl):E209 discussion E209CrossRefPubMed
4.
go back to reference Chow MM, Woo HH, Masaryk TJ, Rasmussen PA (2004) A novel endovascular treatment of a wide-necked basilar apex aneurysm by using a Y-configuration, double-stent technique. AJNR Am J Neuroradiol 25(3):509–512PubMed Chow MM, Woo HH, Masaryk TJ, Rasmussen PA (2004) A novel endovascular treatment of a wide-necked basilar apex aneurysm by using a Y-configuration, double-stent technique. AJNR Am J Neuroradiol 25(3):509–512PubMed
5.
go back to reference Perez-Arjona E, Fessler RD (2004) Basilar artery to bilateral posterior cerebral artery ‘Y stenting’ for endovascular reconstruction of wide-necked basilar apex aneurysms: report of three cases. Neurol Res 26(3):276–281CrossRefPubMed Perez-Arjona E, Fessler RD (2004) Basilar artery to bilateral posterior cerebral artery ‘Y stenting’ for endovascular reconstruction of wide-necked basilar apex aneurysms: report of three cases. Neurol Res 26(3):276–281CrossRefPubMed
6.
go back to reference Moret J, Cognard C, Weill A, Castaings L, Rey A (1997) Reconstruction technic in the treatment of wide-neck intracranial aneurysms. Long-term angiographic and clinical results. Apropos of 56 cases. J Neuroradiol 24(1):30–44PubMed Moret J, Cognard C, Weill A, Castaings L, Rey A (1997) Reconstruction technic in the treatment of wide-neck intracranial aneurysms. Long-term angiographic and clinical results. Apropos of 56 cases. J Neuroradiol 24(1):30–44PubMed
7.
go back to reference Sluzewski M, van Rooij WJ, Beute GN, Nijssen PC (2006) Balloon-assisted coil embolization of intracranial aneurysms: incidence, complications, and angiography results. J Neurosurg 105(3):396–399CrossRefPubMed Sluzewski M, van Rooij WJ, Beute GN, Nijssen PC (2006) Balloon-assisted coil embolization of intracranial aneurysms: incidence, complications, and angiography results. J Neurosurg 105(3):396–399CrossRefPubMed
8.
go back to reference Peluso JP, van Rooij WJ, Sluzewski M, Beute GN (2008) A new self-expandable nitinol stent for the treatment of wide-neck aneurysms: initial clinical experience. AJNR Am J Neuroradiol 29(7):1405–1408CrossRefPubMed Peluso JP, van Rooij WJ, Sluzewski M, Beute GN (2008) A new self-expandable nitinol stent for the treatment of wide-neck aneurysms: initial clinical experience. AJNR Am J Neuroradiol 29(7):1405–1408CrossRefPubMed
9.
go back to reference Mocco J, Snyder KV, Albuquerque FC, Bendok BR, Boulos AS, Carpenter JS et al (2008) Treatment of intracranial aneurysms with the Enterprise stent: a multicenter registry. J Neurosurg 110:35–39 Mocco J, Snyder KV, Albuquerque FC, Bendok BR, Boulos AS, Carpenter JS et al (2008) Treatment of intracranial aneurysms with the Enterprise stent: a multicenter registry. J Neurosurg 110:35–39
10.
go back to reference Weber W, Bendszus M, Kis B, Boulanger T, Solymosi L, Kuhne D (2007) A new self-expanding nitinol stent (Enterprise) for the treatment of wide-necked intracranial aneurysms: initial clinical and angiographic results in 31 aneurysms. Neuroradiology 49(7):555–561CrossRefPubMed Weber W, Bendszus M, Kis B, Boulanger T, Solymosi L, Kuhne D (2007) A new self-expanding nitinol stent (Enterprise) for the treatment of wide-necked intracranial aneurysms: initial clinical and angiographic results in 31 aneurysms. Neuroradiology 49(7):555–561CrossRefPubMed
11.
go back to reference Lozen A, Manjila S, Rhiew R, Fessler R (2009) Y-stent-assisted coil embolization for the management of unruptured cerebral aneurysms: report of six cases. Acta Neurochir. doi:10.1007/s00701-009-0436-9 Lozen A, Manjila S, Rhiew R, Fessler R (2009) Y-stent-assisted coil embolization for the management of unruptured cerebral aneurysms: report of six cases. Acta Neurochir. doi:10.​1007/​s00701-009-0436-9
12.
go back to reference Ebrahimi N, Claus B, Lee CY, Biondi A, Benndorf G (2007) Stent conformity in curved vascular models with simulated aneurysm necks using flat-panel CT: an in vitro study. Am J Neurorad 28(5):823–829 Ebrahimi N, Claus B, Lee CY, Biondi A, Benndorf G (2007) Stent conformity in curved vascular models with simulated aneurysm necks using flat-panel CT: an in vitro study. Am J Neurorad 28(5):823–829
Metadata
Title
Treatment of a wide-necked aneurysm of the anterior cerebral artery using two Enterprise stents in “Y”-configuration stenting technique and coil embolization: a technical note
Authors
Stefan Rohde
Martin Bendszus
Marius Hartmann
Stefan Hähnel
Publication date
01-03-2010
Publisher
Springer-Verlag
Published in
Neuroradiology / Issue 3/2010
Print ISSN: 0028-3940
Electronic ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-009-0603-y

Other articles of this Issue 3/2010

Neuroradiology 3/2010 Go to the issue

Stroke Imaging