Published in: Clinical Oral Investigations 9/2016

01-12-2016 | Original Article

Transmission of light in the visible spectrum (400–700 nm) and blue spectrum (360–540 nm) through CAD/CAM polymers

Authors: Jan-Frederik Güth, Ana Elisa Colle Kauling, Kazuhiko Ueda, Beuer Florian, Michael Stimmelmayr

Published in: Clinical Oral Investigations | Issue 9/2016

Login to get access

Abstract

Objectives

CAD/CAM-fabricated long-term temporary restorations from high-density polymers can be applied for a wide range of indications. Milled from monolithic, mono-colored polymer blocks, the translucency of the material plays an important role for an esthetically acceptable result. The aim of this study was to compare the transmittance through visible light and blue light of CAD CAM polymers to a glass-ceramic material of the same color.

Materials and methods

Ambarino High-Class (AM), Telio-CAD (TC), Zenotec PMMA (ZT), Cercon base PMMA (CB), CAD Temp (CT), Artbloc Temp (AT), Polycon ae (PS), New Outline CAD (NC), QUATTRO DISK Eco PMMA (GQ), Lava Ultimate (LU), and Paradigm MZ 100 (PA) were employed in this study using the feldspathic glass-ceramic Vita Mark II (MK) as control group. Using a spectrophotometer, the overall light transmittance was measured for each material (n = 40) and was calculated as the integration (t c (λ) dλ [10-5]) of all t c values for the wavelengths of blue light (360–540 nm). Results were compared to previous data of the authors for visible light (400 to 700 nm).

Results

Wilcoxon test showed significant differences between the light transmittance of visible and blue light for all materials.

Conclusion

CAD/CAM polymers showed different translucency for blue and visible light. This means clinicians may not conclude from the visible translucency of a material to its permeability for blue light. This influences considerations regarding light curing.

Clinical relevance

CAD/CAM polymers need to be luted adhesively; therefore, clinicians should be aware about the amount of blue light passing through a restoration.
Appendix
Available only for authorised users
Literature
1.
go back to reference Alt V, Hannig M, Wostmann B, Balkenhol M (2011) Fracture strength of temporary fixed partial dentures: CAD/CAM versus directly fabricated restorations. Dent Mater 27:339–347CrossRefPubMed Alt V, Hannig M, Wostmann B, Balkenhol M (2011) Fracture strength of temporary fixed partial dentures: CAD/CAM versus directly fabricated restorations. Dent Mater 27:339–347CrossRefPubMed
2.
go back to reference Goncu Basaran E, Ayna E, Vallittu PK, Lassila LV (2011) Load-bearing capacity of handmade and computer-aided design–computer-aided manufacturing-fabricated three-unit fixed dental prostheses of particulate filler composite. Acta Odontol Scand 69:144–150CrossRefPubMed Goncu Basaran E, Ayna E, Vallittu PK, Lassila LV (2011) Load-bearing capacity of handmade and computer-aided design–computer-aided manufacturing-fabricated three-unit fixed dental prostheses of particulate filler composite. Acta Odontol Scand 69:144–150CrossRefPubMed
3.
go back to reference Stawarczyk B, Ender A, Trottmann A, Özcan M, Fischer J, Hämmerle CH (2012) Load-bearing capacity of CAD/CAM milled polymeric three-unit fixed dental prostheses: effect of aging regimens. Clin Oral Investig 16:1669–1677CrossRefPubMed Stawarczyk B, Ender A, Trottmann A, Özcan M, Fischer J, Hämmerle CH (2012) Load-bearing capacity of CAD/CAM milled polymeric three-unit fixed dental prostheses: effect of aging regimens. Clin Oral Investig 16:1669–1677CrossRefPubMed
4.
go back to reference Güth JF, Almieda e Silva JS, Ramberger M, Beuer F, Edelhoff D (2012) Treatment concept with CAD/CAM-fabricated high-density polymer temporary restorations. J Esthet Restor Dent 24:310–318CrossRefPubMed Güth JF, Almieda e Silva JS, Ramberger M, Beuer F, Edelhoff D (2012) Treatment concept with CAD/CAM-fabricated high-density polymer temporary restorations. J Esthet Restor Dent 24:310–318CrossRefPubMed
5.
go back to reference Güth JF, Almieda e Silva JS, Beuer F, Edelhof D (2012) Enhancing the predictability of complex rehabilitation with a removable CAD/CAM-fabricated long-term temporary prosthesis: a clinical report. J Prosth Dent 197:1–6CrossRef Güth JF, Almieda e Silva JS, Beuer F, Edelhof D (2012) Enhancing the predictability of complex rehabilitation with a removable CAD/CAM-fabricated long-term temporary prosthesis: a clinical report. J Prosth Dent 197:1–6CrossRef
6.
go back to reference Edelhoff D, Beuer F, Schweiger J, Stimmelmayr M, Güth JF (2012) CAD/CAM-generated high-density polymer restorations fort the pretreatment of complex cases: a case report. Quintessence Int 43:457–467PubMed Edelhoff D, Beuer F, Schweiger J, Stimmelmayr M, Güth JF (2012) CAD/CAM-generated high-density polymer restorations fort the pretreatment of complex cases: a case report. Quintessence Int 43:457–467PubMed
7.
go back to reference Stawarczyk B, Basler T, Ender A, Roos M, Ozcan M, Hämmerle C (2012) Effect of surface conditioning with airborne-particle abrasion on the tensile strength of polymeric CAD/CAM crowns luted with self-adhesive and conventional resin cements. J Prosth Dent 107:94–101CrossRef Stawarczyk B, Basler T, Ender A, Roos M, Ozcan M, Hämmerle C (2012) Effect of surface conditioning with airborne-particle abrasion on the tensile strength of polymeric CAD/CAM crowns luted with self-adhesive and conventional resin cements. J Prosth Dent 107:94–101CrossRef
8.
go back to reference Wiegand A, Stucki L, Hoffmann R, Attin T, Stawarczyk B (2015) Repairability of CAD/CAM high-density PMMA- and composite-based polymers. Clin Oral Invest 19:2007–2013CrossRef Wiegand A, Stucki L, Hoffmann R, Attin T, Stawarczyk B (2015) Repairability of CAD/CAM high-density PMMA- and composite-based polymers. Clin Oral Invest 19:2007–2013CrossRef
9.
go back to reference Elsaka SE (2014) Bond strength of novel CAD/CAM restorative materials to self-adhesive resin cement: the effect of surface treatments. J Adhes Dent 16:531–540PubMed Elsaka SE (2014) Bond strength of novel CAD/CAM restorative materials to self-adhesive resin cement: the effect of surface treatments. J Adhes Dent 16:531–540PubMed
10.
go back to reference Kelly JR, Nishimura I, Campbell SD (1996) Ceramics in dentistry: historical roots and current perspectives. J Prosthet Dent 75:18–32CrossRefPubMed Kelly JR, Nishimura I, Campbell SD (1996) Ceramics in dentistry: historical roots and current perspectives. J Prosthet Dent 75:18–32CrossRefPubMed
11.
12.
go back to reference O'Brien WJ, Johnston WM, Fanian F (1985) Double-layer color effects in porcelain systems. J Dent Res 64:940–943CrossRefPubMed O'Brien WJ, Johnston WM, Fanian F (1985) Double-layer color effects in porcelain systems. J Dent Res 64:940–943CrossRefPubMed
13.
go back to reference Powers JM, Dennison JB, Lepeak PJ (1978) Parameters that affect the color of direct restorative resins. J Dent Res 57:876–880CrossRefPubMed Powers JM, Dennison JB, Lepeak PJ (1978) Parameters that affect the color of direct restorative resins. J Dent Res 57:876–880CrossRefPubMed
14.
go back to reference Morgan J (1953) Introduction to geometric and physical optics. McGraw-Hill Book Company, New York Morgan J (1953) Introduction to geometric and physical optics. McGraw-Hill Book Company, New York
15.
go back to reference Brodbelt RHW, O'Brien WJ, Fan PL, Frazer-Dib JG, Yu R (1981) Translucency of human dental enamel. J Dent Res 60:1749–1753CrossRefPubMed Brodbelt RHW, O'Brien WJ, Fan PL, Frazer-Dib JG, Yu R (1981) Translucency of human dental enamel. J Dent Res 60:1749–1753CrossRefPubMed
16.
go back to reference Güth JF, Zuch T, Zwinge S, Engels J, Stimmelmayr M, Edelhoff D (2013) Optical properties of manually and CAD/CAM-fabricated polymers. Dent Mater J 32:1–7CrossRef Güth JF, Zuch T, Zwinge S, Engels J, Stimmelmayr M, Edelhoff D (2013) Optical properties of manually and CAD/CAM-fabricated polymers. Dent Mater J 32:1–7CrossRef
17.
go back to reference Nakajima M, Arimoto A, Prasansuttiporn T, Thanatvarakorn O, Foxton RM, Tagami J (2012) Light transmission characteristics of dentine and resin composites with different thickness. J Dent 40(Suppl 2):e77–e82CrossRefPubMed Nakajima M, Arimoto A, Prasansuttiporn T, Thanatvarakorn O, Foxton RM, Tagami J (2012) Light transmission characteristics of dentine and resin composites with different thickness. J Dent 40(Suppl 2):e77–e82CrossRefPubMed
18.
go back to reference Lie N, Stawarczyk B (2015) Quantification of the amount of blue light passing through monolithic zirconia with respect to thickness and polymerization conditions. J Prosth Dent 113:114–121CrossRef Lie N, Stawarczyk B (2015) Quantification of the amount of blue light passing through monolithic zirconia with respect to thickness and polymerization conditions. J Prosth Dent 113:114–121CrossRef
19.
go back to reference Flury S, Lussi A, Hickel R, Ilie N (2014) Light curing through glass ceramic with a second- and a third-generation LED curing unit: effect of curing mode on the degree of conversion of dual-curing resin cements. Clin Oral Investig 18:809–818CrossRefPubMed Flury S, Lussi A, Hickel R, Ilie N (2014) Light curing through glass ceramic with a second- and a third-generation LED curing unit: effect of curing mode on the degree of conversion of dual-curing resin cements. Clin Oral Investig 18:809–818CrossRefPubMed
20.
go back to reference Ilie N, Stawarczyk B (2014) Quantification of the amount of light passing through zirconia: the effect of material shade, thickness, and curing conditions. J Dent 42:684–690CrossRefPubMed Ilie N, Stawarczyk B (2014) Quantification of the amount of light passing through zirconia: the effect of material shade, thickness, and curing conditions. J Dent 42:684–690CrossRefPubMed
21.
go back to reference Neuman MG, Schmitt CC, Ferreira GC, Corrêa IC (2006) The initiating radical yields and the efficiency of polymerization for various dental photoinitiators excited by different light curing units. Dent Mater 22:576–584CrossRef Neuman MG, Schmitt CC, Ferreira GC, Corrêa IC (2006) The initiating radical yields and the efficiency of polymerization for various dental photoinitiators excited by different light curing units. Dent Mater 22:576–584CrossRef
Metadata
Title
Transmission of light in the visible spectrum (400–700 nm) and blue spectrum (360–540 nm) through CAD/CAM polymers
Authors
Jan-Frederik Güth
Ana Elisa Colle Kauling
Kazuhiko Ueda
Beuer Florian
Michael Stimmelmayr
Publication date
01-12-2016
Publisher
Springer Berlin Heidelberg
Published in
Clinical Oral Investigations / Issue 9/2016
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-016-1755-x

Other articles of this Issue 9/2016

Clinical Oral Investigations 9/2016 Go to the issue