Skip to main content
Top
Published in: JA Clinical Reports 1/2022

Open Access 01-12-2022 | Transesophageal Echocardiography | Case report

Detection of inadvertent passage of guide wire into the false lumen during thoracic endovascular aortic repair of Type B aortic dissection by transesophageal echocardiography

Authors: Mohamed Eissa, Asadollah Mir-Ghassemi, Sudhir Nagpal, Hesham F. Talab

Published in: JA Clinical Reports | Issue 1/2022

Login to get access

Abstract

Background

Thoracic endovascular aortic repair (TEVAR) has become a widely accepted treatment strategy for patients with thoracic aortic pathologies. We present a case of TEVAR where transesophageal echocardiography (TEE) played a crucial role for adequate placement of an endovascular stent graft.

Case presentation

A 71-year-old male received TEVAR for type B aortic dissection. TEE detected both true/false lumens with an intimal tear. A guidewire was inserted into the descending aorta via the left femoral artery; however, angiography failed to identify the precise location of the tip of the guidewire. TEE detected the guide wire passing through the intimal tear into the false lumen, promoted the surgeon to manipulate and advance it to the true lumen, followed by placement of a stent graft. The patient was hemodynamically stable through the whole procedure.

Conclusion

TEE was crucially important for detecting the precise location of the guidewire and preventing complications during TEVAR.
Appendix
Available only for authorised users
Literature
1.
go back to reference Rocchi G, Lofiego C, Biagini E, Piva T, Bracchetti G, Lovato L, et al. Transesophageal echocardiography-guided algorithm for stent-graft implantation in aortic dissection. J Vasc Surg. 2004;40(5):880–5.CrossRef Rocchi G, Lofiego C, Biagini E, Piva T, Bracchetti G, Lovato L, et al. Transesophageal echocardiography-guided algorithm for stent-graft implantation in aortic dissection. J Vasc Surg. 2004;40(5):880–5.CrossRef
2.
go back to reference Agricola E, Slavich M, Rinaldi E, Bertoglio L, Civilini E, Melissano G, et al. Usefulness of contrast-enhanced transoesophageal echocardiography to guide thoracic endovascular aortic repair procedure. Eur Heart J Cardiovasc Imaging. 2016;17(1):67–75.PubMed Agricola E, Slavich M, Rinaldi E, Bertoglio L, Civilini E, Melissano G, et al. Usefulness of contrast-enhanced transoesophageal echocardiography to guide thoracic endovascular aortic repair procedure. Eur Heart J Cardiovasc Imaging. 2016;17(1):67–75.PubMed
3.
go back to reference Etheredge S, Yee J, Smith J, Schonberger S, Goldman M. Successful resection of a large aneurysm of the upper abdominal aorta and replacement with homograft. Surgery. 1955;38:1071–81.PubMed Etheredge S, Yee J, Smith J, Schonberger S, Goldman M. Successful resection of a large aneurysm of the upper abdominal aorta and replacement with homograft. Surgery. 1955;38:1071–81.PubMed
4.
go back to reference DeBakey ME, Creech O, Morris GC. Aneurysm of thoracoabdominal aorta involving the celiac, superior mesenteric, and renal arteries; report of four cases treated by resection and homograft replacement. Ann Surg. 1956;144:549–73.CrossRef DeBakey ME, Creech O, Morris GC. Aneurysm of thoracoabdominal aorta involving the celiac, superior mesenteric, and renal arteries; report of four cases treated by resection and homograft replacement. Ann Surg. 1956;144:549–73.CrossRef
5.
go back to reference Fort ACP, Rubin LA, Meltzer AJ, Schneider DB, Lichtman AD. Perioperative management of endovascular thoracoabdominal aortic aneurysm repair. J Cardiothorac Vasc Anesth. 2017;31(4):1440–59.CrossRef Fort ACP, Rubin LA, Meltzer AJ, Schneider DB, Lichtman AD. Perioperative management of endovascular thoracoabdominal aortic aneurysm repair. J Cardiothorac Vasc Anesth. 2017;31(4):1440–59.CrossRef
6.
go back to reference Plotkin A, Hanks SE, Han SM, Fleischman F, Weaver FA, Magee GA. Endovascular septal fenestration using a radiofrequency wire to salvage inadvertent false lumen deployment of a frozen elephant trunk stent graft. J Vasc Surg Cases Innov Tech. 2019;5(4):553.CrossRef Plotkin A, Hanks SE, Han SM, Fleischman F, Weaver FA, Magee GA. Endovascular septal fenestration using a radiofrequency wire to salvage inadvertent false lumen deployment of a frozen elephant trunk stent graft. J Vasc Surg Cases Innov Tech. 2019;5(4):553.CrossRef
7.
go back to reference Han SM, Gasper WJ, Chuter TA. Endovascular rescue after inadvertent false lumen stent graft implantation. J Vasc Surg. 2016;63:518–22.CrossRef Han SM, Gasper WJ, Chuter TA. Endovascular rescue after inadvertent false lumen stent graft implantation. J Vasc Surg. 2016;63:518–22.CrossRef
8.
go back to reference Follis FM, Filippone G, Stabile A, Montalbano G, Floriano M, Finazzo M, et al. Endovascular graft deployment in the false lumen of type B dissection. Interact Cardiovasc Thorac Surg. 2010;10(4):597–9.CrossRef Follis FM, Filippone G, Stabile A, Montalbano G, Floriano M, Finazzo M, et al. Endovascular graft deployment in the false lumen of type B dissection. Interact Cardiovasc Thorac Surg. 2010;10(4):597–9.CrossRef
Metadata
Title
Detection of inadvertent passage of guide wire into the false lumen during thoracic endovascular aortic repair of Type B aortic dissection by transesophageal echocardiography
Authors
Mohamed Eissa
Asadollah Mir-Ghassemi
Sudhir Nagpal
Hesham F. Talab
Publication date
01-12-2022
Publisher
Springer Berlin Heidelberg
Published in
JA Clinical Reports / Issue 1/2022
Electronic ISSN: 2363-9024
DOI
https://doi.org/10.1186/s40981-022-00539-y

Other articles of this Issue 1/2022

JA Clinical Reports 1/2022 Go to the issue