Skip to main content
Top
Published in: Lasers in Medical Science 4/2009

01-07-2009 | Review Article

Towards automated classification of clinical optical coherence tomography data of dense tissues

Authors: Florian Bazant-Hegemark, Nicholas Stone

Published in: Lasers in Medical Science | Issue 4/2009

Login to get access

Abstract

The native contrast of optical coherence tomography (OCT) data in dense tissues can pose a challenge for clinical decision making. Automated data evaluation is one way of enhancing the clinical utility of measurements. Methods for extracting information from structural OCT data are appraised here. A-scan analysis allows characterization of layer thickness and scattering parameters, whereas image analysis renders itself to segmentation, texture and speckle analysis. All fully automated approaches combine pre-processing, feature registration, data reduction, and classification. Pre-processing requires de-noising, feature recognition, normalization and refining. In the current literature, image exclusion criteria, initial parameters, or manual input are common requirements. The interest of the presented methods lies in the prospect of objective, quick, and/or post-acquisition processing. There is a potential to improve clinical decision making based on automated processing of OCT data.
Literature
3.
go back to reference Ellis DI, Goodacre R (2006) Metabolic fingerprinting in disease diagnosis: biomedical applications of infrared and Raman spectroscopy. Analyst (Lond) 131:875–885 doi:10.1039/b602376m CrossRef Ellis DI, Goodacre R (2006) Metabolic fingerprinting in disease diagnosis: biomedical applications of infrared and Raman spectroscopy. Analyst (Lond) 131:875–885 doi:10.​1039/​b602376m CrossRef
5.
go back to reference Patil CA, Bosschaart N, Keller MD, van Leeuwen TG, Mahadevan-Jansen A (2007) Combined Raman spectroscopy and optical coherence tomography device for tissue characterization. Opt Lett 33:1135–1137 doi:10.1364/OL.33.001135 CrossRef Patil CA, Bosschaart N, Keller MD, van Leeuwen TG, Mahadevan-Jansen A (2007) Combined Raman spectroscopy and optical coherence tomography device for tissue characterization. Opt Lett 33:1135–1137 doi:10.​1364/​OL.​33.​001135 CrossRef
6.
go back to reference Kanter E, Walker R, Marion S, Hoyer P, Barton JK (2005) Optical coherence tomography imaging and fluorescence spectroscopy of a novel rat model of ovarian cancer. Prog Biomed Opt Imaging 6:58610P.1-58610P.8 Kanter E, Walker R, Marion S, Hoyer P, Barton JK (2005) Optical coherence tomography imaging and fluorescence spectroscopy of a novel rat model of ovarian cancer. Prog Biomed Opt Imaging 6:58610P.1-58610P.8
9.
11.
go back to reference Park B, Pierce M, Cense B, de Boer J (2003) Real-time multi-functional optical coherence tomography. Opt Express 11:782–793PubMed Park B, Pierce M, Cense B, de Boer J (2003) Real-time multi-functional optical coherence tomography. Opt Express 11:782–793PubMed
13.
14.
go back to reference Maheswari RU, Takaoka H, Kadono H, Homma R, Tanifuji M (2003) Novel functional imaging technique from brain surface with optical coherence tomography enabling visualization of depth resolved functional structure in vivo. J Neurosci Methods 124:83–92 doi:10.1016/S0165-0270(02)00370-9 PubMedCrossRef Maheswari RU, Takaoka H, Kadono H, Homma R, Tanifuji M (2003) Novel functional imaging technique from brain surface with optical coherence tomography enabling visualization of depth resolved functional structure in vivo. J Neurosci Methods 124:83–92 doi:10.​1016/​S0165-0270(02)00370-9 PubMedCrossRef
17.
go back to reference Knüttel A, Boehlau-Godau M (2000) Spatially confined and temporally resolved refractive index and scattering evaluation in human skin performed with optical coherence tomography. J Biomed Opt 5:83–92 doi:10.1117/1.429972 PubMedCrossRef Knüttel A, Boehlau-Godau M (2000) Spatially confined and temporally resolved refractive index and scattering evaluation in human skin performed with optical coherence tomography. J Biomed Opt 5:83–92 doi:10.​1117/​1.​429972 PubMedCrossRef
20.
go back to reference van der Meer FJ, Faber DJ, Sassoon DMB, Aalders MC, Pasterkamp G, van Leeuwen TG (2005) Localized measurement of optical attenuation coefficients of atherosclerotic plaque constituents by quantitative optical coherence tomography. IEEE Trans Med Imaging 24:1369–1376 doi:10.1109/TMI.2005.854297 PubMedCrossRef van der Meer FJ, Faber DJ, Sassoon DMB, Aalders MC, Pasterkamp G, van Leeuwen TG (2005) Localized measurement of optical attenuation coefficients of atherosclerotic plaque constituents by quantitative optical coherence tomography. IEEE Trans Med Imaging 24:1369–1376 doi:10.​1109/​TMI.​2005.​854297 PubMedCrossRef
22.
go back to reference Ramrath L, Hofmann UG, Huettmann G, Moser A, Schweikard A (2007) Towards automated OCT-based identification of white brain matter. In: Bildverarbeitung für die Medizin–Algorithmen–Systeme–Anwendungen. Springer, Berlin Heidelberg, pp 414–418. ISBN 978-3-540-71091-2 Ramrath L, Hofmann UG, Huettmann G, Moser A, Schweikard A (2007) Towards automated OCT-based identification of white brain matter. In: Bildverarbeitung für die Medizin–Algorithmen–Systeme–Anwendungen. Springer, Berlin Heidelberg, pp 414–418. ISBN 978-3-540-71091-2
23.
go back to reference Turchin IV, Sergeeva EA, Dolin LS, Kamensky VA, Shakhova NM, Richards-Kortum R (2005) Novel algorithm of processing optical coherence tomography images for differentiation of biological tissue pathologies. J Biomed Opt 10:064024 doi:10.1117/1.2137670 PubMedCrossRef Turchin IV, Sergeeva EA, Dolin LS, Kamensky VA, Shakhova NM, Richards-Kortum R (2005) Novel algorithm of processing optical coherence tomography images for differentiation of biological tissue pathologies. J Biomed Opt 10:064024 doi:10.​1117/​1.​2137670 PubMedCrossRef
25.
go back to reference Levitz D, Thrane L, Frosz MH, Andersen PE, Andersen CB, Valanciunaite J et al (2004) Determination of optical scattering properties of highly-scattering media in optical coherence tomography images. Opt Express 12:249–259 doi:10.1364/OPEX.12.000249 PubMedCrossRef Levitz D, Thrane L, Frosz MH, Andersen PE, Andersen CB, Valanciunaite J et al (2004) Determination of optical scattering properties of highly-scattering media in optical coherence tomography images. Opt Express 12:249–259 doi:10.​1364/​OPEX.​12.​000249 PubMedCrossRef
26.
go back to reference Kaiser JF (1990) On a simple algorithm to calculate the ‘energy’ of a signal. Proc IEEE Int Conf Acoust Speech Signal Process (ICASSP’90) 1:381–384 Kaiser JF (1990) On a simple algorithm to calculate the ‘energy’ of a signal. Proc IEEE Int Conf Acoust Speech Signal Process (ICASSP’90) 1:381–384
27.
29.
go back to reference Brodatz P Textures. (Dover Publications Inc., ISBN: 0–486–40699–7, 2000) Brodatz P Textures. (Dover Publications Inc., ISBN: 0–486–40699–7, 2000)
31.
go back to reference MacNeill BD, Jang I-K, Bouma BE, Iftimia N, Takano M, Yabushita H et al (2004) Focal and multi-focal plaque macrophage distributions in patients with acute and stable presentations of coronary artery disease. J Am Coll Cardiol 44:972–979 doi:10.1016/j.jacc.2004.05.066 PubMedCrossRef MacNeill BD, Jang I-K, Bouma BE, Iftimia N, Takano M, Yabushita H et al (2004) Focal and multi-focal plaque macrophage distributions in patients with acute and stable presentations of coronary artery disease. J Am Coll Cardiol 44:972–979 doi:10.​1016/​j.​jacc.​2004.​05.​066 PubMedCrossRef
32.
go back to reference Qi X, Sivak MV Jr, Isenberg G, Willis JE, Rollins AM (2006) Computer-aided diagnosis of dysplasia in Barrett’s esophagus using endoscopic optical coherence tomography. J Biomed Opt 11:044010 doi:10.1117/1.2337314 PubMedCrossRef Qi X, Sivak MV Jr, Isenberg G, Willis JE, Rollins AM (2006) Computer-aided diagnosis of dysplasia in Barrett’s esophagus using endoscopic optical coherence tomography. J Biomed Opt 11:044010 doi:10.​1117/​1.​2337314 PubMedCrossRef
33.
go back to reference Chen Y, Aguirre AD, Hsiung P-L, Huang S-W, Mashimo H, Schmitt JM et al (2008) Effects of axial resolution improvement on optical coherence tomography (OCT) imaging of gastrointestinal tissues. Opt Express 16:2469–2485 doi:10.1364/OE.16.002469 PubMedCrossRef Chen Y, Aguirre AD, Hsiung P-L, Huang S-W, Mashimo H, Schmitt JM et al (2008) Effects of axial resolution improvement on optical coherence tomography (OCT) imaging of gastrointestinal tissues. Opt Express 16:2469–2485 doi:10.​1364/​OE.​16.​002469 PubMedCrossRef
34.
go back to reference Lingley-Papadopoulos CA, Loew MH, Manyak MJ, Zara JM (2008) Computer recognition of cancer in the urinary bladder using optical coherence tomography and texture analysis. J Biomed Opt 13:024003 doi:10.1117/1.2904987 PubMedCrossRef Lingley-Papadopoulos CA, Loew MH, Manyak MJ, Zara JM (2008) Computer recognition of cancer in the urinary bladder using optical coherence tomography and texture analysis. J Biomed Opt 13:024003 doi:10.​1117/​1.​2904987 PubMedCrossRef
37.
go back to reference Gambichler T, Moussa G, Regeniter P, Kasseck C, Hofmann MR, Bechara FG et al (2007) Validation of optical coherence tomography in vivo using cryostat histology. Phys Med Biol 52:85CrossRef Gambichler T, Moussa G, Regeniter P, Kasseck C, Hofmann MR, Bechara FG et al (2007) Validation of optical coherence tomography in vivo using cryostat histology. Phys Med Biol 52:85CrossRef
38.
go back to reference Korde VR, Bonnema GT, Xu W, Krishnamurthy C, Ranger-Moore J, Saboda K et al (2007) Using optical coherence tomography to evaluate skin sun damage and precancer. Lasers Surg Med 39:687–695 doi:10.1002/lsm.20573 PubMedCrossRef Korde VR, Bonnema GT, Xu W, Krishnamurthy C, Ranger-Moore J, Saboda K et al (2007) Using optical coherence tomography to evaluate skin sun damage and precancer. Lasers Surg Med 39:687–695 doi:10.​1002/​lsm.​20573 PubMedCrossRef
39.
go back to reference Lee Y-K, Rhodes WT (1990) Nonlinear image processing by a rotating kernel transformation. Opt Lett 15:1383–1385CrossRefPubMed Lee Y-K, Rhodes WT (1990) Nonlinear image processing by a rotating kernel transformation. Opt Lett 15:1383–1385CrossRefPubMed
42.
go back to reference Hori Y, Yasuno Y, Sakai S, Matsumoto M, Sugawara T, Madjarova V et al (2006) Automatic characterization and segmentation of human skin using three-dimensional optical coherence tomography. Opt Express 14:1862–1877 doi:10.1364/OE.14.001862 PubMedCrossRef Hori Y, Yasuno Y, Sakai S, Matsumoto M, Sugawara T, Madjarova V et al (2006) Automatic characterization and segmentation of human skin using three-dimensional optical coherence tomography. Opt Express 14:1862–1877 doi:10.​1364/​OE.​14.​001862 PubMedCrossRef
46.
48.
go back to reference Iftimia NV, Bouma BE, Pitman MB, Goldberg B, Bressner J, Tearney GJ (2005) A portable, low coherence interferometry based instrument for fine needle aspiration biopsy guidance. Rev Sci Instrum 76:064301 doi:10.1063/1.1921509 CrossRef Iftimia NV, Bouma BE, Pitman MB, Goldberg B, Bressner J, Tearney GJ (2005) A portable, low coherence interferometry based instrument for fine needle aspiration biopsy guidance. Rev Sci Instrum 76:064301 doi:10.​1063/​1.​1921509 CrossRef
49.
go back to reference Goldberg BD, Iftimia NV, Bressner JE, Pitman MB, Halpern E, Bouma BE et al (2008) Automated algorithm for differentiation of human breast tissue using low coherence interferometry for fine needle aspiration biopsy guidance. J Biomed Opt 13:014014 doi:10.1117/1.2837433 PubMedCrossRef Goldberg BD, Iftimia NV, Bressner JE, Pitman MB, Halpern E, Bouma BE et al (2008) Automated algorithm for differentiation of human breast tissue using low coherence interferometry for fine needle aspiration biopsy guidance. J Biomed Opt 13:014014 doi:10.​1117/​1.​2837433 PubMedCrossRef
51.
go back to reference Bazant-Hegemark F, Stone N (2008) Near real-time classification of optical coherence tomography data using principal components fed linear discriminant analysis. J Biomed Opt 13:034002 doi:10.1117/1.2931079 PubMedCrossRef Bazant-Hegemark F, Stone N (2008) Near real-time classification of optical coherence tomography data using principal components fed linear discriminant analysis. J Biomed Opt 13:034002 doi:10.​1117/​1.​2931079 PubMedCrossRef
52.
go back to reference Bazant-Hegemark F, Stone N, Read MD, McCarthy K, Wang RK (2007) Optical coherence tomography (OCT) imaging and computer aided diagnosis of human cervical tissue specimens. Proc SPIE 6627:66270F doi:10.1117/12.728366 CrossRef Bazant-Hegemark F, Stone N, Read MD, McCarthy K, Wang RK (2007) Optical coherence tomography (OCT) imaging and computer aided diagnosis of human cervical tissue specimens. Proc SPIE 6627:66270F doi:10.​1117/​12.​728366 CrossRef
53.
go back to reference Bazant-Hegemark F, Meglinski I, Kandamany N, Monk B, Stone N, (2008) Optical coherence tomography: a potential tool for unsupervised prediction of treatment response for port-wine stains. Photodiagn Photodyn Ther (in press) doi:10.1016/j.pdpdt.2008.09.001 Bazant-Hegemark F, Meglinski I, Kandamany N, Monk B, Stone N, (2008) Optical coherence tomography: a potential tool for unsupervised prediction of treatment response for port-wine stains. Photodiagn Photodyn Ther (in press) doi:10.​1016/​j.​pdpdt.​2008.​09.​001
54.
go back to reference Ismail SM, Colclough AB, Dinnen JS, Eakins D, Evans DMD, Gradwell E et al (1989) Observer variation in histopathological diagnosis and grading of cervical intraepithelial neoplasia. BMJ 298:707–710PubMedCrossRef Ismail SM, Colclough AB, Dinnen JS, Eakins D, Evans DMD, Gradwell E et al (1989) Observer variation in histopathological diagnosis and grading of cervical intraepithelial neoplasia. BMJ 298:707–710PubMedCrossRef
55.
go back to reference Kendall C, Stone N, Shepherd N, Geboes K, Warren B, Bennett R et al (2003) Raman spectroscopy, a potential tool for the objective identification and classification of neoplasia in Barrett’s oesophagus. J Pathol 200:602–609 doi:10.1002/path.1376 PubMedCrossRef Kendall C, Stone N, Shepherd N, Geboes K, Warren B, Bennett R et al (2003) Raman spectroscopy, a potential tool for the objective identification and classification of neoplasia in Barrett’s oesophagus. J Pathol 200:602–609 doi:10.​1002/​path.​1376 PubMedCrossRef
Metadata
Title
Towards automated classification of clinical optical coherence tomography data of dense tissues
Authors
Florian Bazant-Hegemark
Nicholas Stone
Publication date
01-07-2009
Publisher
Springer-Verlag
Published in
Lasers in Medical Science / Issue 4/2009
Print ISSN: 0268-8921
Electronic ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-008-0615-6

Other articles of this Issue 4/2009

Lasers in Medical Science 4/2009 Go to the issue