Skip to main content
Top
Published in: Surgical Endoscopy 2/2004

01-02-2004 | Original article

Toward totally endoscopic coronary artery surgery

Authors: R. H. J. Trimlett, A. C. De Souza, A. S. Coonar, K. M. Jurgens, R. Kuenzler, J. R. Pepper

Published in: Surgical Endoscopy | Issue 2/2004

Login to get access

Abstract

Background: Here we explore a method of using robotics to reduce morbidity and mortality in conventional coronary surgery. Methods: Using a robotic surgical system two surgeons completed five steps: (1) 80 synthetic suture exercises; (2) 76 left internal thoracic artery to left anterior descending (LIMA-to-LAD) on porcine hearts; (3) cadaveric port placement for assessing optimal access; (4) endoscopic stabilization in the live porcine model; and, finally (5) eight clinical LIMA-to-LADs performed robotically. Results: After 70 hours training, mean dry lab times fell from 7.0 and 5.8 min to 5.7 and 5.1 min in the two surgeonstab series. Wet lab times fell from 40.1 and 28.5 min to 28.8 and 19.2 min. In the clinical series of eight patients there were no mortalities; all had uncomplicated postoperative recovery and all were angina free at 6-week follow-up. Conclusion: The learning curve for robotic training is short, and reproducible results can be achieved clinically, after appropriate training, resulting in real patient benefit.
Literature
2.
go back to reference Falk V, Klima U, Wimmer-Greinecker G (2002) Ventrica Magnetic Vascular Positioner (MVP). 38th Annual Meeting of the Society of Thoracic Surgeons, TechCon 2002, Fort Lauderdale, FL, USA, February Falk V, Klima U, Wimmer-Greinecker G (2002) Ventrica Magnetic Vascular Positioner (MVP). 38th Annual Meeting of the Society of Thoracic Surgeons, TechCon 2002, Fort Lauderdale, FL, USA, February
3.
go back to reference Favorolo, RG 1998Critical analysis of coronary artery bypass graft surgery: a 30-year journey.J AM Coll Cardiol311B63BCrossRefPubMed Favorolo, RG 1998Critical analysis of coronary artery bypass graft surgery: a 30-year journey.J AM Coll Cardiol311B63BCrossRefPubMed
4.
go back to reference Jansen, EWL, Borst, C, Lahpor, JR, et al. 1998Coronary artery bypass grafting without cardiopulmonary bypass using the Octopus method: results in the first 100 patients.J Thorac Cardiovasc Surg1166067PubMed Jansen, EWL, Borst, C, Lahpor, JR,  et al. 1998Coronary artery bypass grafting without cardiopulmonary bypass using the Octopus method: results in the first 100 patients.J Thorac Cardiovasc Surg1166067PubMed
5.
go back to reference Kiviluoto, T, Siren, J, Luukkonen, P, Kivilaakso, E 1998Randomised trial of laparoscopic versus open cholecystectomy for acute and gangrenous cholecystitis.Lancet351321325CrossRefPubMed Kiviluoto, T, Siren, J, Luukkonen, P, Kivilaakso, E 1998Randomised trial of laparoscopic versus open cholecystectomy for acute and gangrenous cholecystitis.Lancet351321325CrossRefPubMed
6.
go back to reference Koh, TW, Carr-White, GS, DeSouza, AC, et al. 1999Effect of coronary occlusion on left ventricular function with and without collateral supply during beating heart surgery.Heart81285291PubMed Koh, TW, Carr-White, GS, DeSouza, AC,  et al. 1999Effect of coronary occlusion on left ventricular function with and without collateral supply during beating heart surgery.Heart81285291PubMed
7.
go back to reference Leon MB, et al. (2002) Sirius Study. 14th Annual Transcatheter Cardiovascular Therapeutics. Lenox Hill Hospital and the Cardiovascular Research Foundation, New York Leon MB, et al. (2002) Sirius Study. 14th Annual Transcatheter Cardiovascular Therapeutics. Lenox Hill Hospital and the Cardiovascular Research Foundation, New York
8.
go back to reference Rivetti, LA, Gandra, SMA 1997Initial experience using an intraluminal shunt during revascularisation of the beating heart.Ann Thorac Surg6317421747CrossRefPubMed Rivetti, LA, Gandra, SMA 1997Initial experience using an intraluminal shunt during revascularisation of the beating heart.Ann Thorac Surg6317421747CrossRefPubMed
9.
go back to reference Shennib, H, Lee, AGL, Akin, J 1997Safe and effective method of stabilisation for coronary artery bypass grafting on the beating heart.Ann Thorac Surg63988992CrossRefPubMed Shennib, H, Lee, AGL, Akin, J 1997Safe and effective method of stabilisation for coronary artery bypass grafting on the beating heart.Ann Thorac Surg63988992CrossRefPubMed
11.
go back to reference Wantanabe, G, Takahashi, M, Misaki, T, et al. 1999Beating heart endoscopic coronary artery surgery.Lancet25421312132CrossRef Wantanabe, G, Takahashi, M, Misaki, T,  et al. 1999Beating heart endoscopic coronary artery surgery.Lancet25421312132CrossRef
Metadata
Title
Toward totally endoscopic coronary artery surgery
Authors
R. H. J. Trimlett
A. C. De Souza
A. S. Coonar
K. M. Jurgens
R. Kuenzler
J. R. Pepper
Publication date
01-02-2004
Publisher
Springer-Verlag
Published in
Surgical Endoscopy / Issue 2/2004
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-002-9147-5

Other articles of this Issue 2/2004

Surgical Endoscopy 2/2004 Go to the issue