Skip to main content
Top
Published in: European Radiology 10/2003

01-10-2003 | Experimental

Toward comparability of coronary magnetic resonance angiography: proposal for a standardized quantitative assessment

Authors: Martijn S. Dirksen, Hildo J. Lamb, Rob van der Geest, Albert de Roos

Published in: European Radiology | Issue 10/2003

Login to get access

Abstract

A method is proposed for the quantitative assessment of coronary magnetic resonance angiography (MRA) acquisitions. The method is based on four parameters: signal-to-noise ratio (SNR); contrast-to-noise ratio (CNR); vessel length; and vessel-edge definition. A pig model (n=7) was used to illustrate the proposed quantitative analysis method. Three-dimensional gradient-echo coronary MRA was performed with and without exogenous contrast enhancement using a gadolinium-based blood-pool contrast agent (Vistarem, Guerbet, Aulnay-Sous-Bois, France). The acquired images could be well differentiated based on the four parameters. The SNR was calculated as 9.0±1.4 vs 10.4±2.1, the CNR as 6.2±0.8 vs 8.2±0.9, the vessel length as 48.2±11.6 vs 86.5±13.8 mm, and the vessel-edge definition as 4.9±1.5 vs 7.7±3.4. Different coronary MRA techniques can be evaluated objectively with the combined use of SNR, CNR, vessel length, and vessel-edge parameters.
Literature
1.
go back to reference Kim WY, Danias PG, Stuber M et al. (2001) Coronary magnetic resonance angiography for the detection of coronary stenoses. N Engl J Med 345:1863–1869PubMed Kim WY, Danias PG, Stuber M et al. (2001) Coronary magnetic resonance angiography for the detection of coronary stenoses. N Engl J Med 345:1863–1869PubMed
2.
go back to reference van Geuns RJ, Wielopolski PA, de Bruin HG et al. (2000) MR coronary angiography with breath-hold targeted volumes: preliminary clinical results. Radiology 217:270–277PubMed van Geuns RJ, Wielopolski PA, de Bruin HG et al. (2000) MR coronary angiography with breath-hold targeted volumes: preliminary clinical results. Radiology 217:270–277PubMed
3.
go back to reference Sandstede JJ, Pabst T, Beer M et al. (1999) Three-dimensional MR coronary angiography using the navigator technique compared with conventional coronary angiography. Am J Roentgenol 172:135–139 Sandstede JJ, Pabst T, Beer M et al. (1999) Three-dimensional MR coronary angiography using the navigator technique compared with conventional coronary angiography. Am J Roentgenol 172:135–139
4.
go back to reference Huber A, Nikolaou K, Gonschior P et al. (1999) Navigator echo-based respiratory gating for three-dimensional MR coronary angiography: results from healthy volunteers and patients with proximal coronary artery stenoses. Am J Roentgenol 173:95–101 Huber A, Nikolaou K, Gonschior P et al. (1999) Navigator echo-based respiratory gating for three-dimensional MR coronary angiography: results from healthy volunteers and patients with proximal coronary artery stenoses. Am J Roentgenol 173:95–101
5.
go back to reference Botnar RM, Stuber M, Danias PG, Kissinger KV, Manning WJ (1999) Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA. Circulation 99:3139–3148PubMed Botnar RM, Stuber M, Danias PG, Kissinger KV, Manning WJ (1999) Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA. Circulation 99:3139–3148PubMed
6.
go back to reference Wielopolski PA, van Geuns RJ, de Feyter PJ, Oudkerk M (1998) Breath-hold coronary MR angiography with volume-targeted imaging. Radiology 209:209–219PubMed Wielopolski PA, van Geuns RJ, de Feyter PJ, Oudkerk M (1998) Breath-hold coronary MR angiography with volume-targeted imaging. Radiology 209:209–219PubMed
7.
go back to reference Stuber M, Botnar RM, Danias PG, Kissinger KV, Manning WJ (1999) Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: comparison of navigator locations. Radiology 212:579–587PubMed Stuber M, Botnar RM, Danias PG, Kissinger KV, Manning WJ (1999) Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: comparison of navigator locations. Radiology 212:579–587PubMed
8.
go back to reference Fayad ZA, Fuster V, Fallon JT et al. (2000) Noninvasive in-vivo human coronary artery lumen and wall imaging using black-blood magnetic resonance imaging. Circulation 102:506–510PubMed Fayad ZA, Fuster V, Fallon JT et al. (2000) Noninvasive in-vivo human coronary artery lumen and wall imaging using black-blood magnetic resonance imaging. Circulation 102:506–510PubMed
9.
go back to reference Pruessmann KP, Weiger M, Boesiger P (2001) Sensitivity encoded cardiac MRI. J Cardiovasc Magn Reson 3:1–9CrossRefPubMed Pruessmann KP, Weiger M, Boesiger P (2001) Sensitivity encoded cardiac MRI. J Cardiovasc Magn Reson 3:1–9CrossRefPubMed
10.
go back to reference Börnert P, Aldefeld B, Nehrke K (2001) Improved 3D spiral imaging for coronary MR angiography. Magn Reson Med 45:172–175CrossRefPubMed Börnert P, Aldefeld B, Nehrke K (2001) Improved 3D spiral imaging for coronary MR angiography. Magn Reson Med 45:172–175CrossRefPubMed
11.
12.
go back to reference Dirksen MS, Lamb HJ, Kunz P et al. (2003) Improved MR coronary angiography with use of a new rapid-clearance blood-pool-contrast-agent in pigs. Radiology 227:802–808PubMed Dirksen MS, Lamb HJ, Kunz P et al. (2003) Improved MR coronary angiography with use of a new rapid-clearance blood-pool-contrast-agent in pigs. Radiology 227:802–808PubMed
13.
go back to reference Li D, Zheng J, Weinmann HJ (2001) Contrast-enhanced MR imaging of coronary arteries: comparison of intra- and extravascular contrast agents in swine. Radiology 218:670–678PubMed Li D, Zheng J, Weinmann HJ (2001) Contrast-enhanced MR imaging of coronary arteries: comparison of intra- and extravascular contrast agents in swine. Radiology 218:670–678PubMed
14.
go back to reference Hofman MB, Henson RE, Kovacs SJ et al. (1999) Blood-pool-agent strongly improves 3D magnetic resonance coronary angiography using an inversion pre-pulse. Magn Reson Med 41:360–367CrossRefPubMed Hofman MB, Henson RE, Kovacs SJ et al. (1999) Blood-pool-agent strongly improves 3D magnetic resonance coronary angiography using an inversion pre-pulse. Magn Reson Med 41:360–367CrossRefPubMed
15.
go back to reference Zheng J, Li D, Cavagna FM et al. (2001) Contrast-enhanced coronary MR angiography: relationship between coronary artery delineation and blood T1. J Magn Reson Imaging 14:348–354CrossRefPubMed Zheng J, Li D, Cavagna FM et al. (2001) Contrast-enhanced coronary MR angiography: relationship between coronary artery delineation and blood T1. J Magn Reson Imaging 14:348–354CrossRefPubMed
16.
go back to reference Li D, Carr JC, Shea SM et al. (2001) Coronary arteries: magnetization-prepared contrast-enhanced three-dimensional volume-targeted breath-hold MR angiography. Radiology 219:270–277PubMed Li D, Carr JC, Shea SM et al. (2001) Coronary arteries: magnetization-prepared contrast-enhanced three-dimensional volume-targeted breath-hold MR angiography. Radiology 219:270–277PubMed
17.
go back to reference Stuber M, Botnar RM, Danias PG et al. (1999) Contrast agent-enhanced, free-breathing, three-dimensional coronary magnetic resonance angiography. J Magn Reson Imaging 10:790–799CrossRefPubMed Stuber M, Botnar RM, Danias PG et al. (1999) Contrast agent-enhanced, free-breathing, three-dimensional coronary magnetic resonance angiography. J Magn Reson Imaging 10:790–799CrossRefPubMed
18.
go back to reference Kessler W, Laub G, Achenbach S et al. (1999) Coronary arteries: MR angiography with fast contrast-enhanced three-dimensional breath-hold imaging—initial experience. Radiology 210:566–572PubMed Kessler W, Laub G, Achenbach S et al. (1999) Coronary arteries: MR angiography with fast contrast-enhanced three-dimensional breath-hold imaging—initial experience. Radiology 210:566–572PubMed
19.
go back to reference Taupitz M, Schnorr J, Wagner S et al. (2001) Coronary magnetic resonance angiography: experimental evaluation of the new rapid-clearance blood-pool contrast medium P792. Magn Reson Med 46:932–938CrossRefPubMed Taupitz M, Schnorr J, Wagner S et al. (2001) Coronary magnetic resonance angiography: experimental evaluation of the new rapid-clearance blood-pool contrast medium P792. Magn Reson Med 46:932–938CrossRefPubMed
20.
go back to reference Port M, Corot C, Rousseaux O et al. (2001) P792: a rapid-clearance blood-pool-agent for magnetic resonance imaging: preliminary results. MAGMA 12:121–127PubMed Port M, Corot C, Rousseaux O et al. (2001) P792: a rapid-clearance blood-pool-agent for magnetic resonance imaging: preliminary results. MAGMA 12:121–127PubMed
21.
go back to reference Stillman AE, Wilke N, Jerosch-Herold M (1997) Use of an intravascular T1 contrast agent to improve MR cine myocardial: blood-pool definition in man. J Magn Reson Imaging 7:765–767PubMed Stillman AE, Wilke N, Jerosch-Herold M (1997) Use of an intravascular T1 contrast agent to improve MR cine myocardial: blood-pool definition in man. J Magn Reson Imaging 7:765–767PubMed
22.
go back to reference Sandstede JJ, Pabst T, Wacker C et al. (2001) Breath-hold 3D MR coronary angiography with a new intravascular contrast agent (feruglose): first clinical experiences. Magn Reson Imaging 19:201–205CrossRefPubMed Sandstede JJ, Pabst T, Wacker C et al. (2001) Breath-hold 3D MR coronary angiography with a new intravascular contrast agent (feruglose): first clinical experiences. Magn Reson Imaging 19:201–205CrossRefPubMed
23.
go back to reference Taylor AM, Panting JR, Keegan J et al. (1999) Safety and preliminary findings with the intravascular contrast agent NC100150 injection for MR coronary angiography. J Magn Reson Imaging 9:220–227CrossRefPubMed Taylor AM, Panting JR, Keegan J et al. (1999) Safety and preliminary findings with the intravascular contrast agent NC100150 injection for MR coronary angiography. J Magn Reson Imaging 9:220–227CrossRefPubMed
24.
Metadata
Title
Toward comparability of coronary magnetic resonance angiography: proposal for a standardized quantitative assessment
Authors
Martijn S. Dirksen
Hildo J. Lamb
Rob van der Geest
Albert de Roos
Publication date
01-10-2003
Publisher
Springer-Verlag
Published in
European Radiology / Issue 10/2003
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-003-2007-4

Other articles of this Issue 10/2003

European Radiology 10/2003 Go to the issue

EuroPACS

MIR 2003