Skip to main content
Top
Published in: European Radiology 10/2008

01-10-2008 | Magnetic Resonance

Total-body contrast-enhanced MRA on a short, wide-bore 1.5-T system: intra-individual comparison of Gd-BOPTA and Gd-DOTA

Authors: M. Rasmus, J. Bremerich, T. Egelhof, R. W. Huegli, G. Bongartz, D. Bilecen

Published in: European Radiology | Issue 10/2008

Login to get access

Abstract

Total-body contrast-enhanced MRA (CE-MRA) provides information of the entire vascular system according to a one-stop-shop approach. Short, wide-bore scanners have not yet been used for total-body CE-MRA, probably due to their restricted field of view in the z-direction. The purpose of this feasibility study is to introduce an image protocol for total-body MRA on a short, wide-bore system. The protocol includes five to six table-moving steps and two injection runs. Two pharmacologically different contrast materials (CM) were applied in ten healthy volunteers in view of possible CM-dependent influences on the protocol outcome (Gd-Bopta, Gd-Dota). Differences consisted of significantly higher CNR with Gd-Bopta with a mean of 73.8 ± 38.7 versus 69.1 ± 34.3 (p = 0.008), significantly better arterial visualization values with Gd-Dota with a mean of 1.26 ± 0.44 versus 1.53 ± 0.73 (p = 0.003) and a tendency to less venous overlay with Gd-Dota, mean 1.19 ± 0.44 and 1.34 ± 0.72, respectively (p = 0.065) (two-tailed Wilcoxon matched-pairs test). Overall 94% of the steps were valued as qualitatively excellent or good. The good results with both CM suggest a transfer to further patient evaluation.
Literature
1.
go back to reference Prince MR, Narasimham DL, Stanley JC et al (1995) Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and its major branches. Radiology 197:785–792PubMed Prince MR, Narasimham DL, Stanley JC et al (1995) Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and its major branches. Radiology 197:785–792PubMed
2.
go back to reference Snidow JJ, Aisen AM, Harris VJ et al (1995) Iliac artery MR angiography: comparison of three-dimensional gadolinium-enhanced and two-dimensional time-of-flight techniques. Radiology 196:371–378PubMed Snidow JJ, Aisen AM, Harris VJ et al (1995) Iliac artery MR angiography: comparison of three-dimensional gadolinium-enhanced and two-dimensional time-of-flight techniques. Radiology 196:371–378PubMed
3.
go back to reference Hany TF, Debatin JF, Leung DA, Pfammatter T (1997) Evaluation of the aortoiliac and renal arteries: comparison of breath-hold, contrast-enhanced, three-dimensional MR angiography with conventional catheter angiography. Radiology 204:357–362PubMed Hany TF, Debatin JF, Leung DA, Pfammatter T (1997) Evaluation of the aortoiliac and renal arteries: comparison of breath-hold, contrast-enhanced, three-dimensional MR angiography with conventional catheter angiography. Radiology 204:357–362PubMed
4.
go back to reference Rofsky NM, Johnson G, Adelman MA, Rosen RJ, Krinsky GA, Weinreb JC (1997) Peripheral vascular disease evaluated with reduced-dose gadolinium-enhanced MR angiography. Radiology 205:163–169PubMed Rofsky NM, Johnson G, Adelman MA, Rosen RJ, Krinsky GA, Weinreb JC (1997) Peripheral vascular disease evaluated with reduced-dose gadolinium-enhanced MR angiography. Radiology 205:163–169PubMed
5.
go back to reference Ruehm SG, Hany TF, Pfammatter T, Schneider E, Ladd M, Debatin JF (2000) Pelvic and lower extremity arterial imaging: diagnostic performance of three-dimensional contrast-enhanced MR angiography. AJR 174:1127–1135PubMed Ruehm SG, Hany TF, Pfammatter T, Schneider E, Ladd M, Debatin JF (2000) Pelvic and lower extremity arterial imaging: diagnostic performance of three-dimensional contrast-enhanced MR angiography. AJR 174:1127–1135PubMed
6.
go back to reference Ruehm SG, Goyen M, Barkhausen J et al (2001) Rapid magnetic resonance angiography for detection of atherosclerosis. Lancet 357:1086–1091PubMedCrossRef Ruehm SG, Goyen M, Barkhausen J et al (2001) Rapid magnetic resonance angiography for detection of atherosclerosis. Lancet 357:1086–1091PubMedCrossRef
7.
go back to reference Vogt FM, Ajaj W, Hunold P et al (2004) Venous compression at high-spatial-resolution three-dimensional MR angiography of peripheral arteries. Radiology 233:913–920PubMedCrossRef Vogt FM, Ajaj W, Hunold P et al (2004) Venous compression at high-spatial-resolution three-dimensional MR angiography of peripheral arteries. Radiology 233:913–920PubMedCrossRef
8.
go back to reference Ladd SC, Debatin JF, Stang A et al (2007) Whole-body MR vascular screening detects unsuspected concomitant vascular disease in coronary heart disease patients. Eur Radiol 17:1035–1045PubMedCrossRef Ladd SC, Debatin JF, Stang A et al (2007) Whole-body MR vascular screening detects unsuspected concomitant vascular disease in coronary heart disease patients. Eur Radiol 17:1035–1045PubMedCrossRef
9.
go back to reference Pereles FS, Collins JD, Carr JC et al (2006) Accuracy of stepping-table lower extremity MR angiography with dual-level bolus timing and separate calf acquisition: hybrid peripheral MR angiography. Radiology 240:283–290PubMedCrossRef Pereles FS, Collins JD, Carr JC et al (2006) Accuracy of stepping-table lower extremity MR angiography with dual-level bolus timing and separate calf acquisition: hybrid peripheral MR angiography. Radiology 240:283–290PubMedCrossRef
10.
go back to reference Meissner OA, Rieger J, Weber C et al (2005) Critical limb ischemia: hybrid MR angiography compared with DSA. Radiology 235:308–318PubMedCrossRef Meissner OA, Rieger J, Weber C et al (2005) Critical limb ischemia: hybrid MR angiography compared with DSA. Radiology 235:308–318PubMedCrossRef
11.
go back to reference Goyen M, Herborn CU, Kröger K, Ruehm SG, Debatin JF (2006) Total-body 3D magnetic resonance angiography influences the management of patients with peripheral arterial occlusive disease. Eur Radiol 16:685–691PubMedCrossRef Goyen M, Herborn CU, Kröger K, Ruehm SG, Debatin JF (2006) Total-body 3D magnetic resonance angiography influences the management of patients with peripheral arterial occlusive disease. Eur Radiol 16:685–691PubMedCrossRef
12.
go back to reference Hansen T, Wikström J, Johansson LO, Lind L, Ahlström H (2007) The prevalence and quantification of atherosclerosis in an elderly population assessed by whole-body magnetic resonance angiography. Arterioscler Thromb Vasc Biol 27:649–654PubMedCrossRef Hansen T, Wikström J, Johansson LO, Lind L, Ahlström H (2007) The prevalence and quantification of atherosclerosis in an elderly population assessed by whole-body magnetic resonance angiography. Arterioscler Thromb Vasc Biol 27:649–654PubMedCrossRef
13.
go back to reference Herborn CU, Goyen M, Quick H (2004) Whole-body 3D MR angiography of patients with peripheral arterial occlusive disease. AJR 182:1427–1434PubMed Herborn CU, Goyen M, Quick H (2004) Whole-body 3D MR angiography of patients with peripheral arterial occlusive disease. AJR 182:1427–1434PubMed
14.
go back to reference Cavagna FM, Maggioni F, Castelli PM et al (1997) Gadolinium chelates with weak binding to serum proteins: a new class of high-efficiency, general purpose contrast agents for magnetic resonance imaging. Invest Radiol 32:780–796PubMedCrossRef Cavagna FM, Maggioni F, Castelli PM et al (1997) Gadolinium chelates with weak binding to serum proteins: a new class of high-efficiency, general purpose contrast agents for magnetic resonance imaging. Invest Radiol 32:780–796PubMedCrossRef
15.
go back to reference Kirchin MA, Pirovano GP, Spinazzi A (1998) Gadobenate dimeglumine (Gd-BOPTA). An overview. Invest Radiol 33:798–809PubMedCrossRef Kirchin MA, Pirovano GP, Spinazzi A (1998) Gadobenate dimeglumine (Gd-BOPTA). An overview. Invest Radiol 33:798–809PubMedCrossRef
16.
go back to reference Magerstadt M, Gansow OA, Brechbiel MW et al (1986) Gd(DOTA): an alternative to Gd(DTPA) as a T1, 2 relaxation agent for NMR imaging or spectroscopy. Magn Reson Med 3:808–812PubMedCrossRef Magerstadt M, Gansow OA, Brechbiel MW et al (1986) Gd(DOTA): an alternative to Gd(DTPA) as a T1, 2 relaxation agent for NMR imaging or spectroscopy. Magn Reson Med 3:808–812PubMedCrossRef
17.
go back to reference Rohrer M, Bauer H, Mintorovitch J, Requardt M, Weinmann HJ (2005) Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths. Invest Radiol 40:715–724PubMedCrossRef Rohrer M, Bauer H, Mintorovitch J, Requardt M, Weinmann HJ (2005) Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths. Invest Radiol 40:715–724PubMedCrossRef
18.
go back to reference Meaney JF (2003) Magnetic resonance angiography of the peripheral arteries: current status. Eur Radiol 13:836–852PubMed Meaney JF (2003) Magnetic resonance angiography of the peripheral arteries: current status. Eur Radiol 13:836–852PubMed
19.
go back to reference Patel N, Sacks D, Patel RI et al (2003) Society of interventional radiology technology assessment committee. SIR reporting standards for the treatment of acute limb ischemia with use of transluminal removal of arterial thrombus. J Vasc Interv Radiol 14:453–465 Patel N, Sacks D, Patel RI et al (2003) Society of interventional radiology technology assessment committee. SIR reporting standards for the treatment of acute limb ischemia with use of transluminal removal of arterial thrombus. J Vasc Interv Radiol 14:453–465
20.
go back to reference Fenchel M, Requardt M, Tomaschko K et al (2005) Whole-body MR angiography using a novel 32-receiving-channel MR system with surface coil technology: first clinical experience. J Magn Reson Imaging 21:596–603PubMedCrossRef Fenchel M, Requardt M, Tomaschko K et al (2005) Whole-body MR angiography using a novel 32-receiving-channel MR system with surface coil technology: first clinical experience. J Magn Reson Imaging 21:596–603PubMedCrossRef
21.
go back to reference Klessen C, Asbach P, Hein PA et al (2006) [Whole-body MR angiography: comparison of two protocols for contrast media injection]. Rofo 178:484–490PubMed Klessen C, Asbach P, Hein PA et al (2006) [Whole-body MR angiography: comparison of two protocols for contrast media injection]. Rofo 178:484–490PubMed
22.
go back to reference Wyttenbach R, Gianella S, Alerci M, Braghetti A, Cozzi L, Gallino A (2003) Prospective blinded evaluation of Gd-Dota- versus Gd-Bopta-enhanced peripheral MR angiography, as compared with digital subtraction angiography. Radiology 227:261–269PubMedCrossRef Wyttenbach R, Gianella S, Alerci M, Braghetti A, Cozzi L, Gallino A (2003) Prospective blinded evaluation of Gd-Dota- versus Gd-Bopta-enhanced peripheral MR angiography, as compared with digital subtraction angiography. Radiology 227:261–269PubMedCrossRef
23.
go back to reference Bilecen D, Aschwanden M, Heidecker HG, Bongartz G (2004) Optimized assessment of hand vascularization on contrast-enhanced MR angiography with a subsystolic continuous compression technique. AJR 182:180–182PubMed Bilecen D, Aschwanden M, Heidecker HG, Bongartz G (2004) Optimized assessment of hand vascularization on contrast-enhanced MR angiography with a subsystolic continuous compression technique. AJR 182:180–182PubMed
24.
go back to reference Herborn CU, Ajaj W, Goyen M, Massing S, Ruehm SG, Debatin JF (2004) Peripheral vasculature: whole-body MR angiography with midfemoral venous compression—initial experience. Radiology 230:872–878PubMedCrossRef Herborn CU, Ajaj W, Goyen M, Massing S, Ruehm SG, Debatin JF (2004) Peripheral vasculature: whole-body MR angiography with midfemoral venous compression—initial experience. Radiology 230:872–878PubMedCrossRef
25.
go back to reference Gluecker TM, Bongartz G, Ledermann HP, Bilecen D (2006) MR angiography of the hand with subsystolic cuff-compression optimization of injection parameters. AJR 187:905–910PubMedCrossRef Gluecker TM, Bongartz G, Ledermann HP, Bilecen D (2006) MR angiography of the hand with subsystolic cuff-compression optimization of injection parameters. AJR 187:905–910PubMedCrossRef
26.
go back to reference Bilecen D, Jager KA, Aschwanden M, Heidecker HG, Schulte AC, Bongartz G (2004) Cuff-compression of the proximal calf to reduce venous contamination in contrast-enhanced stepping-table magnetic Resonance angiography. Acta Radiol 45:510–515PubMedCrossRef Bilecen D, Jager KA, Aschwanden M, Heidecker HG, Schulte AC, Bongartz G (2004) Cuff-compression of the proximal calf to reduce venous contamination in contrast-enhanced stepping-table magnetic Resonance angiography. Acta Radiol 45:510–515PubMedCrossRef
27.
go back to reference Vogt FM, Zenge MO, Ladd ME et al (2007) Peripheral vascular disease: comparison of continuous MR angiography and conventional MR angiography-pilot study. Radiology 243:229–238PubMedCrossRef Vogt FM, Zenge MO, Ladd ME et al (2007) Peripheral vascular disease: comparison of continuous MR angiography and conventional MR angiography-pilot study. Radiology 243:229–238PubMedCrossRef
28.
go back to reference Kruger DG, Riederer SJ, Grimm RC, Rossman PJ (2002) Continuously moving table data acquisition method for long FOV contrast-enhanced MRA and whole-body MRI. Magn Reson Med 47:224–231PubMedCrossRef Kruger DG, Riederer SJ, Grimm RC, Rossman PJ (2002) Continuously moving table data acquisition method for long FOV contrast-enhanced MRA and whole-body MRI. Magn Reson Med 47:224–231PubMedCrossRef
Metadata
Title
Total-body contrast-enhanced MRA on a short, wide-bore 1.5-T system: intra-individual comparison of Gd-BOPTA and Gd-DOTA
Authors
M. Rasmus
J. Bremerich
T. Egelhof
R. W. Huegli
G. Bongartz
D. Bilecen
Publication date
01-10-2008
Publisher
Springer-Verlag
Published in
European Radiology / Issue 10/2008
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-008-0976-z

Other articles of this Issue 10/2008

European Radiology 10/2008 Go to the issue