Published in: Clinical Oral Investigations 5/2016

01-06-2016 | Original Article

Tooth-implant-supported posterior fixed dental prostheses with zirconia frameworks: 3-year clinical result

Authors: Florian Beuer, Caroline Sachs, Julian Groesser, Jan-Frederik Gueth, Michael Stimmelmayr

Published in: Clinical Oral Investigations | Issue 5/2016

Login to get access

Abstract

Objectives

This case series compared the clinical survival of tooth-implant-supported (TI-S) and tooth-supported (T-S) three-unit fixed dental prostheses (FDPs) with zirconia frameworks and described the incidence of biological and technical complications.

Materials and methods

Forty-four patients received 27 TI-S FDPs and 22 T-S FDPs. Twenty-seven titanium screw implants were inserted at the dislodged position of two missing posterior teeth. All implants were provided with customized zirconia abutments. Zirconia frameworks were fabricated by a CAD/CAM system and veneered in powder build-up technique. All restorations were cemented with glass ionomer. Baseline evaluation was performed 2 weeks after cementation with recall examinations performed at 6, 12, 24 and 36 months by calibrated investigators. Survival probabilities according to Kaplan-Meier were calculated. Gingival parameters and bone loss were assessed and statistically evaluated.

Results

The mean service time of the FDPs was 35 months (±6). Two technical complications (fracture of veneering porcelain) were observed. One biological complication was recorded. The Kaplan-Meier survival probability was 93.9 % for all types of complications and 100 % related to restorations in service. The type of abutment support (TI-S vs. T-S) had no significant influence on the survival probability (p = 0.412, log rank test). No difference of the gingival parameters was detected between implants and natural teeth.

Conclusions

Tooth-implant-supported zirconia-based FDPs showed similar clinical performance compared to tooth-supported zirconia-based FDPs.

Clinical relevance

Within the limitations of this case series, tooth-implant-supported FDPs with zirconia frameworks seem to be a reliable treatment option.
Literature
1.
go back to reference Buser D, Mericske-Stern R, Bernard JP, Behneke A, Behneke N, Hirt HP, Belser UC, Lang NP (1997) Long-term evaluation of non-submerged ITI implants. Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants. Clin Oral Implants Res 8:161–172CrossRefPubMed Buser D, Mericske-Stern R, Bernard JP, Behneke A, Behneke N, Hirt HP, Belser UC, Lang NP (1997) Long-term evaluation of non-submerged ITI implants. Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants. Clin Oral Implants Res 8:161–172CrossRefPubMed
2.
go back to reference Bragger U, Aeschlimann S, Burgin W, Hammerle CH, Lang NP (2001) Biological and technical complications and failures with fixed partial dentures (FPD) on implants and teeth after four to five years of function. Clin Oral Implants Res 12:26–34CrossRefPubMed Bragger U, Aeschlimann S, Burgin W, Hammerle CH, Lang NP (2001) Biological and technical complications and failures with fixed partial dentures (FPD) on implants and teeth after four to five years of function. Clin Oral Implants Res 12:26–34CrossRefPubMed
3.
go back to reference Naert IE, Duyck JA, Hosny MM, Quirynen M, van Steenberghe D (2001) Freestanding and tooth-implant connected prostheses in the treatment of partially edentulous patients part II: an up to 15-years radiographic evaluation. Clin Oral Implants Res 12:245–251CrossRefPubMed Naert IE, Duyck JA, Hosny MM, Quirynen M, van Steenberghe D (2001) Freestanding and tooth-implant connected prostheses in the treatment of partially edentulous patients part II: an up to 15-years radiographic evaluation. Clin Oral Implants Res 12:245–251CrossRefPubMed
4.
go back to reference Naert IE, Duyck JA, Hosny MM, Van Steenberghe D (2001) Freestanding and tooth-implant connected prostheses in the treatment of partially edentulous patients. Part I: an up to 15-years clinical evaluation. Clin Oral Implants Res 12:237–244CrossRefPubMed Naert IE, Duyck JA, Hosny MM, Van Steenberghe D (2001) Freestanding and tooth-implant connected prostheses in the treatment of partially edentulous patients. Part I: an up to 15-years clinical evaluation. Clin Oral Implants Res 12:237–244CrossRefPubMed
5.
go back to reference Beuer F, Edelhoff D, Gernet W, Sorensen JA (2009) Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs). Clin Oral Investig 13:445–451CrossRefPubMed Beuer F, Edelhoff D, Gernet W, Sorensen JA (2009) Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs). Clin Oral Investig 13:445–451CrossRefPubMed
6.
go back to reference Beuer F, Stimmelmayr M, Gernet W, Edelhoff D, Guh JF, Naumann M (2010) Prospective study of zirconia-based restorations: 3-year clinical results. Quintessence Int 41:631–637PubMed Beuer F, Stimmelmayr M, Gernet W, Edelhoff D, Guh JF, Naumann M (2010) Prospective study of zirconia-based restorations: 3-year clinical results. Quintessence Int 41:631–637PubMed
7.
go back to reference Beuer F, Schweiger J, Edelhoff D (2008) Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br Dent J 204:505–511CrossRefPubMed Beuer F, Schweiger J, Edelhoff D (2008) Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br Dent J 204:505–511CrossRefPubMed
8.
go back to reference Scurria MS, Bader JD, Shugars DA (1998) Meta-analysis of fixed partial denture survival: prostheses and abutments. J Prosthet Dent 79:459–464CrossRefPubMed Scurria MS, Bader JD, Shugars DA (1998) Meta-analysis of fixed partial denture survival: prostheses and abutments. J Prosthet Dent 79:459–464CrossRefPubMed
9.
go back to reference Walter M, Reppel PD, Boning K, Freesmeyer WB (1999) Six-year follow-up of titanium and high-gold porcelain-fused-to-metal fixed partial dentures. J Oral Rehabil 26:91–96CrossRefPubMed Walter M, Reppel PD, Boning K, Freesmeyer WB (1999) Six-year follow-up of titanium and high-gold porcelain-fused-to-metal fixed partial dentures. J Oral Rehabil 26:91–96CrossRefPubMed
10.
go back to reference Sailer I, Pjetursson BE, Zwahlen M, Hammerle CH (2007) A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part II: fixed dental prostheses. Clin Oral Implants Res 18(Suppl 3):86–96CrossRefPubMed Sailer I, Pjetursson BE, Zwahlen M, Hammerle CH (2007) A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part II: fixed dental prostheses. Clin Oral Implants Res 18(Suppl 3):86–96CrossRefPubMed
11.
go back to reference Beuer F, Aggstaller H, Edelhoff D, Gernet W (2008) Effect of preparation design on the fracture resistance of zirconia crown copings. Dent Mater J 27:362–367CrossRefPubMed Beuer F, Aggstaller H, Edelhoff D, Gernet W (2008) Effect of preparation design on the fracture resistance of zirconia crown copings. Dent Mater J 27:362–367CrossRefPubMed
12.
go back to reference Edelhoff D, Florian B, Florian W, Johnen C (2008) HIP zirconia fixed partial dentures—clinical results after 3 years of clinical service. Quintessence Int 39:459–471PubMed Edelhoff D, Florian B, Florian W, Johnen C (2008) HIP zirconia fixed partial dentures—clinical results after 3 years of clinical service. Quintessence Int 39:459–471PubMed
13.
go back to reference Tinschert J, Schulze KA, Natt G, Latzke P, Heussen N, Spiekermann H (2008) Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results. Int J Prosthodont 21:217–222PubMed Tinschert J, Schulze KA, Natt G, Latzke P, Heussen N, Spiekermann H (2008) Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results. Int J Prosthodont 21:217–222PubMed
14.
go back to reference Gomes AL, Montero J (2011) Zirconia implant abutments: a review. Med Oral Patol Oral Cir Bucal 16:e50–e55CrossRefPubMed Gomes AL, Montero J (2011) Zirconia implant abutments: a review. Med Oral Patol Oral Cir Bucal 16:e50–e55CrossRefPubMed
15.
go back to reference Blatz MB, Bergler M, Holst S, Block MS (2009) Zirconia abutments for single-tooth implants—rationale and clinical guidelines. J Oral Maxillofac Surg 67:74–81CrossRefPubMed Blatz MB, Bergler M, Holst S, Block MS (2009) Zirconia abutments for single-tooth implants—rationale and clinical guidelines. J Oral Maxillofac Surg 67:74–81CrossRefPubMed
16.
go back to reference Sailer I, Philipp A, Zembic A, Pjetursson BE, Hammerle CH, Zwahlen M (2009) A systematic review of the performance of ceramic and metal implant abutments supporting fixed implant reconstructions. Clin Oral Implants Res 20(Suppl 4):4–31CrossRefPubMed Sailer I, Philipp A, Zembic A, Pjetursson BE, Hammerle CH, Zwahlen M (2009) A systematic review of the performance of ceramic and metal implant abutments supporting fixed implant reconstructions. Clin Oral Implants Res 20(Suppl 4):4–31CrossRefPubMed
17.
go back to reference Glauser R, Sailer I, Wohlwend A, Studer S, Schibli M, Scharer P (2004) Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions: 4-year results of a prospective clinical study. Int J Prosthodont 17:285–290PubMed Glauser R, Sailer I, Wohlwend A, Studer S, Schibli M, Scharer P (2004) Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions: 4-year results of a prospective clinical study. Int J Prosthodont 17:285–290PubMed
18.
go back to reference Rammelsberg P, Schwarz S, Schroeder C, Bermejo JL, Gabbert O (2013) Short-term complications of implant-supported and combined tooth-implant-supported fixed dental prostheses. Clin Oral Implants Res 24:758–762CrossRefPubMed Rammelsberg P, Schwarz S, Schroeder C, Bermejo JL, Gabbert O (2013) Short-term complications of implant-supported and combined tooth-implant-supported fixed dental prostheses. Clin Oral Implants Res 24:758–762CrossRefPubMed
19.
go back to reference Sailer I, Zembic A, Jung RE, Siegenthaler D, Holderegger C, Hammerle CH (2009) Randomized controlled clinical trial of customized zirconia and titanium implant abutments for canine and posterior single-tooth implant reconstructions: preliminary results at 1 year of function. Clin Oral Implants Res 20:219–225CrossRefPubMed Sailer I, Zembic A, Jung RE, Siegenthaler D, Holderegger C, Hammerle CH (2009) Randomized controlled clinical trial of customized zirconia and titanium implant abutments for canine and posterior single-tooth implant reconstructions: preliminary results at 1 year of function. Clin Oral Implants Res 20:219–225CrossRefPubMed
20.
go back to reference Zembic A, Sailer I, Jung RE, Hammerle CH (2009) Randomized-controlled clinical trial of customized zirconia and titanium implant abutments for single-tooth implants in canine and posterior regions: 3-year results. Clin Oral Implants Res 20:802–808CrossRefPubMed Zembic A, Sailer I, Jung RE, Hammerle CH (2009) Randomized-controlled clinical trial of customized zirconia and titanium implant abutments for single-tooth implants in canine and posterior regions: 3-year results. Clin Oral Implants Res 20:802–808CrossRefPubMed
21.
go back to reference Visscher CM, Naeije M, De Laat A, Michelotti A, Nilner M, Craane B, Ekberg E, Farella M, Lobbezoo F (2009) Diagnostic accuracy of temporomandibular disorder pain tests: a multicenter study. J Orofac Pain 23:108–114PubMed Visscher CM, Naeije M, De Laat A, Michelotti A, Nilner M, Craane B, Ekberg E, Farella M, Lobbezoo F (2009) Diagnostic accuracy of temporomandibular disorder pain tests: a multicenter study. J Orofac Pain 23:108–114PubMed
22.
go back to reference Hasanain F, Durham J, Moufti A, Steen IN, Wassell RW (2009) Adapting the diagnostic definitions of the RDC/TMD to routine clinical practice: a feasibility study. J Dent 37:955–962CrossRefPubMed Hasanain F, Durham J, Moufti A, Steen IN, Wassell RW (2009) Adapting the diagnostic definitions of the RDC/TMD to routine clinical practice: a feasibility study. J Dent 37:955–962CrossRefPubMed
23.
go back to reference Ahmad M, Hollender L, Anderson Q, Kartha K, Ohrbach R, Truelove EL, John MT, Schiffman EL (2009) Research diagnostic criteria for temporomandibular disorders (RDC/TMD): development of image analysis criteria and examiner reliability for image analysis. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 107:844–860CrossRefPubMedPubMedCentral Ahmad M, Hollender L, Anderson Q, Kartha K, Ohrbach R, Truelove EL, John MT, Schiffman EL (2009) Research diagnostic criteria for temporomandibular disorders (RDC/TMD): development of image analysis criteria and examiner reliability for image analysis. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 107:844–860CrossRefPubMedPubMedCentral
24.
go back to reference DeLuca S, Habsha E, Zarb GA (2006) The effect of smoking on osseointegrated dental implants. Part I: implant survival. Int J Prosthodont 19:491–498PubMed DeLuca S, Habsha E, Zarb GA (2006) The effect of smoking on osseointegrated dental implants. Part I: implant survival. Int J Prosthodont 19:491–498PubMed
25.
go back to reference Balshe AA, Eckert SE, Koka S, Assad DA, Weaver AL (2008) The effects of smoking on the survival of smooth- and rough-surface dental implants. Int J Oral Maxillofac Implants 23:1117–1122PubMed Balshe AA, Eckert SE, Koka S, Assad DA, Weaver AL (2008) The effects of smoking on the survival of smooth- and rough-surface dental implants. Int J Oral Maxillofac Implants 23:1117–1122PubMed
26.
go back to reference Queiroz DA, Cortelli JR, Holzhausen M, Rodrigues E, Aquino DR, Saad WA (2009) Smoking increases salivary arginase activity in patients with dental implants. Clin Oral Investig 13:263–267CrossRefPubMed Queiroz DA, Cortelli JR, Holzhausen M, Rodrigues E, Aquino DR, Saad WA (2009) Smoking increases salivary arginase activity in patients with dental implants. Clin Oral Investig 13:263–267CrossRefPubMed
27.
go back to reference Orenstein IH (1992) The surgical template: a prescription for implant success. Implant Dent 1:182–184CrossRefPubMed Orenstein IH (1992) The surgical template: a prescription for implant success. Implant Dent 1:182–184CrossRefPubMed
28.
go back to reference Mitov G, Gessner J, Lohbauer U, Woll K, Muecklich F, Pospiech P (2011) Subcritical crack growth behavior and life data analysis of two types of dental Y-TZP ceramics. Dent Mater 27:684–691CrossRefPubMed Mitov G, Gessner J, Lohbauer U, Woll K, Muecklich F, Pospiech P (2011) Subcritical crack growth behavior and life data analysis of two types of dental Y-TZP ceramics. Dent Mater 27:684–691CrossRefPubMed
29.
go back to reference Mormann W, Regolati B, Lutz F, Saxer UP (1975) The gingivitis fluorescein test in recruits. Helv Odontol Acta 19:27–30PubMed Mormann W, Regolati B, Lutz F, Saxer UP (1975) The gingivitis fluorescein test in recruits. Helv Odontol Acta 19:27–30PubMed
30.
go back to reference Saxer UP, Muhlemann HR (1975) Motivation and education. SSO Schweiz Monatsschr Zahnheilkd 85:905–919PubMed Saxer UP, Muhlemann HR (1975) Motivation and education. SSO Schweiz Monatsschr Zahnheilkd 85:905–919PubMed
31.
go back to reference Loe H, Silness J (1963) Periodontal disease in pregnancy. I. Prevalence and severity. Acta Odontol Scand 21:533–551CrossRefPubMed Loe H, Silness J (1963) Periodontal disease in pregnancy. I. Prevalence and severity. Acta Odontol Scand 21:533–551CrossRefPubMed
32.
go back to reference Schmitter M, Mussotter K, Rammelsberg P, Stober T, Ohlmann B, Gabbert O (2009) Clinical performance of extended zirconia frameworks for fixed dental prostheses: two-year results. J Oral Rehabil 36:610–615CrossRefPubMed Schmitter M, Mussotter K, Rammelsberg P, Stober T, Ohlmann B, Gabbert O (2009) Clinical performance of extended zirconia frameworks for fixed dental prostheses: two-year results. J Oral Rehabil 36:610–615CrossRefPubMed
33.
go back to reference Mundt T, Heinemann F, Schankath C, Schwahn C, Biffar R (2013) Retrospective and clinical evaluation of retrievable, tooth-implant supported zirconia-ceramic restorations. Acta Odontol Scand 71:1326–1334CrossRefPubMed Mundt T, Heinemann F, Schankath C, Schwahn C, Biffar R (2013) Retrospective and clinical evaluation of retrievable, tooth-implant supported zirconia-ceramic restorations. Acta Odontol Scand 71:1326–1334CrossRefPubMed
34.
go back to reference Pjetursson BE, Tan K, Lang NP, Bragger U, Egger M, Zwahlen M (2004) A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years. Clin Oral Implants Res 15:667–676CrossRefPubMed Pjetursson BE, Tan K, Lang NP, Bragger U, Egger M, Zwahlen M (2004) A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years. Clin Oral Implants Res 15:667–676CrossRefPubMed
35.
go back to reference Sailer I, Feher A, Filser F, Gauckler LJ, Luthy H, Hammerle CH (2007) Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont 20:383–388PubMed Sailer I, Feher A, Filser F, Gauckler LJ, Luthy H, Hammerle CH (2007) Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont 20:383–388PubMed
36.
go back to reference Molin MK, Karlsson SL (2008) Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs. Int J Prosthodont 21:223–227PubMed Molin MK, Karlsson SL (2008) Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs. Int J Prosthodont 21:223–227PubMed
37.
go back to reference Beuer F, Schweiger J, Eichberger M, Kappert HF, Gernet W, Edelhoff D (2009) High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings—a new fabrication mode for all-ceramic restorations. Dent Mater 25:121–128CrossRefPubMed Beuer F, Schweiger J, Eichberger M, Kappert HF, Gernet W, Edelhoff D (2009) High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings—a new fabrication mode for all-ceramic restorations. Dent Mater 25:121–128CrossRefPubMed
38.
go back to reference Christensen RP, Ploeger BJ (2010) A clinical comparison of zirconia, metal and alumina fixed-prosthesis frameworks veneered with layered or pressed ceramic: a three-year report. J Am Dent Assoc 141:1317–1329CrossRefPubMed Christensen RP, Ploeger BJ (2010) A clinical comparison of zirconia, metal and alumina fixed-prosthesis frameworks veneered with layered or pressed ceramic: a three-year report. J Am Dent Assoc 141:1317–1329CrossRefPubMed
39.
go back to reference Rosentritt M, Steiger D, Behr M, Handel G, Kolbeck C (2009) Influence of substructure design and spacer settings on the in vitro performance of molar zirconia crowns. J Dent 37:978–983CrossRefPubMed Rosentritt M, Steiger D, Behr M, Handel G, Kolbeck C (2009) Influence of substructure design and spacer settings on the in vitro performance of molar zirconia crowns. J Dent 37:978–983CrossRefPubMed
40.
go back to reference Keough BE, Kay HB, Sager RD, Keen E (2011) Clinical performance of scientifically designed, hot isostatic-pressed (HIP’d) zirconia cores in a bilayered all-ceramic system. Compend Contin Educ Dent 32:58–68PubMed Keough BE, Kay HB, Sager RD, Keen E (2011) Clinical performance of scientifically designed, hot isostatic-pressed (HIP’d) zirconia cores in a bilayered all-ceramic system. Compend Contin Educ Dent 32:58–68PubMed
41.
go back to reference Larsson C, Vult von Steyern P, Sunzel B, Nilner K (2006) All-ceramic two- to five-unit implant-supported reconstructions. A randomized, prospective clinical trial. Swed Dent J 30:45–53PubMed Larsson C, Vult von Steyern P, Sunzel B, Nilner K (2006) All-ceramic two- to five-unit implant-supported reconstructions. A randomized, prospective clinical trial. Swed Dent J 30:45–53PubMed
42.
go back to reference Stawarczyk B, Ozcan M, Schmutz F, Trottmann A, Roos M, Hammerle CH (2013) Two-body wear of monolithic, veneered and glazed zirconia and their corresponding enamel antagonists. Acta Odontol Scand 71:102–112CrossRefPubMed Stawarczyk B, Ozcan M, Schmutz F, Trottmann A, Roos M, Hammerle CH (2013) Two-body wear of monolithic, veneered and glazed zirconia and their corresponding enamel antagonists. Acta Odontol Scand 71:102–112CrossRefPubMed
43.
go back to reference Dittmer MP, Dittmer S, Borchers L, Kohorst P, Stiesch M (2012) Influence of the interface design on the yield force of the implant-abutment complex before and after cyclic mechanical loading. J Prosthodont Res 56:19–24CrossRefPubMed Dittmer MP, Dittmer S, Borchers L, Kohorst P, Stiesch M (2012) Influence of the interface design on the yield force of the implant-abutment complex before and after cyclic mechanical loading. J Prosthodont Res 56:19–24CrossRefPubMed
44.
go back to reference Beuer F, Stimmelmayr M, Gueth JF, Edelhoff D, Naumann M (2012) In vitro performance of full-contour zirconia single crowns. Dent Mater 28:449–456CrossRefPubMed Beuer F, Stimmelmayr M, Gueth JF, Edelhoff D, Naumann M (2012) In vitro performance of full-contour zirconia single crowns. Dent Mater 28:449–456CrossRefPubMed
45.
go back to reference Raigrodski AJ, Chiche GJ, Potiket N, Hochstedler JL, Mohamed SE, Billiot S, Mercante DE (2006) The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study. J Prosthet Dent 96:237–244CrossRefPubMed Raigrodski AJ, Chiche GJ, Potiket N, Hochstedler JL, Mohamed SE, Billiot S, Mercante DE (2006) The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study. J Prosthet Dent 96:237–244CrossRefPubMed
46.
go back to reference Santing HJ, Meijer HJ, Raghoebar GM, Ozcan M (2012) Fracture strength and failure mode of maxillary implant-supported provisional single crowns: a comparison of composite resin crowns fabricated directly over PEEK abutments and solid titanium abutments. Clin Implant Dent Relat Res 14:882–889CrossRefPubMed Santing HJ, Meijer HJ, Raghoebar GM, Ozcan M (2012) Fracture strength and failure mode of maxillary implant-supported provisional single crowns: a comparison of composite resin crowns fabricated directly over PEEK abutments and solid titanium abutments. Clin Implant Dent Relat Res 14:882–889CrossRefPubMed
47.
go back to reference Sarafidou K, Stiesch M, Dittmer MP, Jorn D, Borchers L, Kohorst P (2012) Load-bearing capacity of artificially aged zirconia fixed dental prostheses with heterogeneous abutment supports. Clin Oral Investig 16:961–968CrossRefPubMed Sarafidou K, Stiesch M, Dittmer MP, Jorn D, Borchers L, Kohorst P (2012) Load-bearing capacity of artificially aged zirconia fixed dental prostheses with heterogeneous abutment supports. Clin Oral Investig 16:961–968CrossRefPubMed
48.
go back to reference Dittmer MP, Kohorst P, Borchers L, Stiesch M (2010) Influence of the supporting structure on stress distribution in all-ceramic FPDs. Int J Prosthodont 23:63–68PubMed Dittmer MP, Kohorst P, Borchers L, Stiesch M (2010) Influence of the supporting structure on stress distribution in all-ceramic FPDs. Int J Prosthodont 23:63–68PubMed
49.
go back to reference Sarafidou K, Stiesch M, Dittmer MP, Borchers L, Kohorst P (2011) Load-bearing capacity of implant-supported, tooth-supported, and combined zirconia-fixed dental prostheses. Implant Dent 20:311–317CrossRefPubMed Sarafidou K, Stiesch M, Dittmer MP, Borchers L, Kohorst P (2011) Load-bearing capacity of implant-supported, tooth-supported, and combined zirconia-fixed dental prostheses. Implant Dent 20:311–317CrossRefPubMed
Metadata
Title
Tooth-implant-supported posterior fixed dental prostheses with zirconia frameworks: 3-year clinical result
Authors
Florian Beuer
Caroline Sachs
Julian Groesser
Jan-Frederik Gueth
Michael Stimmelmayr
Publication date
01-06-2016
Publisher
Springer Berlin Heidelberg
Published in
Clinical Oral Investigations / Issue 5/2016
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-015-1594-1

Other articles of this Issue 5/2016

Clinical Oral Investigations 5/2016 Go to the issue