Skip to main content
Top
Published in: European Journal of Applied Physiology 2/2008

01-09-2008 | Original Article

Thermal comfort range of a military cold protection glove: database by thermophysiological simulation

Authors: Carsten Zimmermann, Wolfgang H. Uedelhoven, Bernhard Kurz, Karl Jochen Glitz

Published in: European Journal of Applied Physiology | Issue 2/2008

Login to get access

Abstract

The thermal insulation properties of a military wet/cold protection glove of the German Bundeswehr were investigated using the thermophysiological simulation device CYBOR with a heated full-scale hand model. The aim of this study was the physiology related and more reliable estimation of a database for the thermal comfort range of the glove in terms of environmental limit temperatures and maximum safe wearing times (limit times). For that purpose the simulation device CYBOR is equipped with a control feature allowing the simulation of the physiological effect that the blood flow into the hands as the dominant heat source is reduced with decreasing skin temperature (vasoconstriction effect). In the simulation test, the criterion defining the thermal comfort range of the glove was the maintenance of a minimum hand phantom skin temperature of 15°C. For various assumed metabolic rates between 50 and 175 W m−2 and environmental temperatures down to −22°C, the maximum safe wearing times within the thermal comfort range of the military glove were estimated between only 20 min and almost 1 h. The used simulation scenario for the prediction of environmental limit temperatures, however, tends to deliver too low values in correlation to the estimated limit times and needs further critical consideration. The estimated data concerning the thermal comfort range of the wet/cold protection glove of the German Bundeswehr leads to the recommendation for a use of this model in mild cold climatic regions. The presented thermophysiological simulation procedure for the evaluation of the cold protection properties of gloves in terms of maximum safe wearing times within the thermal comfort range can be a useful tool to establish practical operating instructions for soldiers or civilians acting in cold environments.
Literature
go back to reference Anttonen H, Kinnunen K, Niskanen J (2005) Functional glove combinations for cold conditions. In: Holmér I, Kuklane K, Gao C (eds) Environmental Ergonomics XI 2005, Ystad, pp 449–451 Anttonen H, Kinnunen K, Niskanen J (2005) Functional glove combinations for cold conditions. In: Holmér I, Kuklane K, Gao C (eds) Environmental Ergonomics XI 2005, Ystad, pp 449–451
go back to reference Brajkovic D, Ducharme MB (2002) Maintaining finger dexterity in the cold: a comparison of passive, direct and indirect hand heating methods. In: NATO conference proceedings of the human factors and medicine panel symposium on blowing hot and cold protecting against climatic extremes. Dresden, Germany, 8–10 October 2001, pp 20.1–20.6 Brajkovic D, Ducharme MB (2002) Maintaining finger dexterity in the cold: a comparison of passive, direct and indirect hand heating methods. In: NATO conference proceedings of the human factors and medicine panel symposium on blowing hot and cold protecting against climatic extremes. Dresden, Germany, 8–10 October 2001, pp 20.1–20.6
go back to reference Chen F, Liu ZY, Holmér I (1996) Hand and finger skin temperatures in convective and contact cold exposure. Eur J Appl Physiol 72:372–379CrossRef Chen F, Liu ZY, Holmér I (1996) Hand and finger skin temperatures in convective and contact cold exposure. Eur J Appl Physiol 72:372–379CrossRef
go back to reference Chen F, Nilsson H, Holmér I (1999) Evaluation of hand and finger heat loss with a heated hand model. Appl Human Sci 18:135–140PubMedCrossRef Chen F, Nilsson H, Holmér I (1999) Evaluation of hand and finger heat loss with a heated hand model. Appl Human Sci 18:135–140PubMedCrossRef
go back to reference Diebschlag W, Heidinger F, Kurz B, Droste R (1992) Physiologic-experimental investigations on foot and hand wear construction of thermoregulative simulation devices. In: Research report no. BA V2 E/B52B/I0177/I5944, Federal Office for Military Technology and Procurement Diebschlag W, Heidinger F, Kurz B, Droste R (1992) Physiologic-experimental investigations on foot and hand wear construction of thermoregulative simulation devices. In: Research report no. BA V2 E/B52B/I0177/I5944, Federal Office for Military Technology and Procurement
go back to reference Enander A (1986) Sensory reactions and performance in moderate cold. Arbete och Hälsa, vol 32, Sölna Enander A (1986) Sensory reactions and performance in moderate cold. Arbete och Hälsa, vol 32, Sölna
go back to reference Forster RE, Ferris BG, Day R (1946) The relationship between total heat exchange and blood flow in the hand at various ambient temperatures. Am J Physiol 146:600 Forster RE, Ferris BG, Day R (1946) The relationship between total heat exchange and blood flow in the hand at various ambient temperatures. Am J Physiol 146:600
go back to reference Geng Q (2001) Hand cooling, protection and performance in cold environment. Ph.D. thesis. Luleå University of Technology Geng Q (2001) Hand cooling, protection and performance in cold environment. Ph.D. thesis. Luleå University of Technology
go back to reference Giedraityte L (2005) Identification and validation of risk factors in cold work. Ph.D. thesis, Luleå University of Technology Giedraityte L (2005) Identification and validation of risk factors in cold work. Ph.D. thesis, Luleå University of Technology
go back to reference Glitz KJ, Seibel U, Kurz B, Uedelhoven W, Leyk D (2005) Thermophysiological and self-perceived sensations during cold exposure of the hands: data for a biophysical device. In: Holmér I, Kuklane K, Gao C (eds) Environmental Ergonomics XI 2005, Ystad, pp 564–566 Glitz KJ, Seibel U, Kurz B, Uedelhoven W, Leyk D (2005) Thermophysiological and self-perceived sensations during cold exposure of the hands: data for a biophysical device. In: Holmér I, Kuklane K, Gao C (eds) Environmental Ergonomics XI 2005, Ystad, pp 564–566
go back to reference Goldman RF (1994) Local finger insulation and its effect on cooling rate. In: Frim J, Ducharme MB, Tikuisis P (eds) In: Sixth international conference on environmental ergonomics. Montebello, Canada Goldman RF (1994) Local finger insulation and its effect on cooling rate. In: Frim J, Ducharme MB, Tikuisis P (eds) In: Sixth international conference on environmental ergonomics. Montebello, Canada
go back to reference Hamlet MP (1988) Human Cold Injuries. In: Pandolf K, Sawka M, Gonzalez R (eds) Human performance: Physiology and environmental medicine at terrestrial extremes. Benchmark Press, Indianapolis Hamlet MP (1988) Human Cold Injuries. In: Pandolf K, Sawka M, Gonzalez R (eds) Human performance: Physiology and environmental medicine at terrestrial extremes. Benchmark Press, Indianapolis
go back to reference Hellström B (1965) Local effects of acclimatization to cold in man. University Press, Oslo Hellström B (1965) Local effects of acclimatization to cold in man. University Press, Oslo
go back to reference Heus R, Daanen HAM, Havenith G (1995) Review of physiological criteria for functioning of unprotected hands in the cold. In: Tikuisis P et al (eds) Handbook on predicting responses to cold exposure, NATO AC/243 Panel 8; Appl Ergon 26(1):5–13 Heus R, Daanen HAM, Havenith G (1995) Review of physiological criteria for functioning of unprotected hands in the cold. In: Tikuisis P et al (eds) Handbook on predicting responses to cold exposure, NATO AC/243 Panel 8; Appl Ergon 26(1):5–13
go back to reference Kurz B, Uedelhoven W, Nocker W (1998) Cybor concept for thermophysiological simulation of dry and wet heat flow. In: Proceedings of the eighth international conference on environmental ergonomics (San Diego) Kurz B, Uedelhoven W, Nocker W (1998) Cybor concept for thermophysiological simulation of dry and wet heat flow. In: Proceedings of the eighth international conference on environmental ergonomics (San Diego)
go back to reference Molnar GW (1957) Heat transfer through hand. In: Fisher FR (eds) Protection and functioning of the hands in cold climates. National Academy Sciences, National Research Council, Washington, pp 15–45 Molnar GW (1957) Heat transfer through hand. In: Fisher FR (eds) Protection and functioning of the hands in cold climates. National Academy Sciences, National Research Council, Washington, pp 15–45
go back to reference Raman ER, Vanhuyse VJ (1975) Temperature dependence of the circulation pattern in the upper extremities. J Physiol 249:197–210PubMed Raman ER, Vanhuyse VJ (1975) Temperature dependence of the circulation pattern in the upper extremities. J Physiol 249:197–210PubMed
go back to reference Shitzer A (1996) Models to describe finger behavior under cold-stress. In: Shapiro Y, Moran DS, Epstein Y (eds) Environmental ergonomics: recent progress and new frontiers. Freund Publishing House, London, Tel Aviv, pp 161–164 Shitzer A (1996) Models to describe finger behavior under cold-stress. In: Shapiro Y, Moran DS, Epstein Y (eds) Environmental ergonomics: recent progress and new frontiers. Freund Publishing House, London, Tel Aviv, pp 161–164
go back to reference Shitzer A, Stroschein LA, Gonzalez RR, Pandolf KB (1993) Lumped parameter fingertip model exhibiting cold induced vasodilatation. In: Roemer RB (ed) ASME advances in bioheat and mass transfer, HTD-vol 268, pp 61–67 Shitzer A, Stroschein LA, Gonzalez RR, Pandolf KB (1993) Lumped parameter fingertip model exhibiting cold induced vasodilatation. In: Roemer RB (ed) ASME advances in bioheat and mass transfer, HTD-vol 268, pp 61–67
go back to reference Shitzer A, Stroschein LA, Vital P, Gonzalez RR, Pandolf KB (1994) Numerical model of the thermal behaviour of an extremity in a cold environment including counter-current heat exchange between the blood vessels. In: Technical Report no. T94 10, US Army Research Institute of Environmental Medicine, Natick, MA Shitzer A, Stroschein LA, Vital P, Gonzalez RR, Pandolf KB (1994) Numerical model of the thermal behaviour of an extremity in a cold environment including counter-current heat exchange between the blood vessels. In: Technical Report no. T94 10, US Army Research Institute of Environmental Medicine, Natick, MA
go back to reference Shitzer A, Stroschein LA, Gonzalez RR, Pandolf KB (1996) Application of a lumped-parameter heat exchange model to cold-induced temperature and blood flow measurements in the finger-tip. J Therm Biol 21(4):213–222CrossRef Shitzer A, Stroschein LA, Gonzalez RR, Pandolf KB (1996) Application of a lumped-parameter heat exchange model to cold-induced temperature and blood flow measurements in the finger-tip. J Therm Biol 21(4):213–222CrossRef
go back to reference Shitzer A, Stroschein LA, Vital P, Gonzalez RR, Pandolf KB (1997) Numerical analysis of an extremity in a cold environment including countercurrent arterio-venous heat exchange. ASME Trans J Biomech Eng 119(2):179–186CrossRef Shitzer A, Stroschein LA, Vital P, Gonzalez RR, Pandolf KB (1997) Numerical analysis of an extremity in a cold environment including countercurrent arterio-venous heat exchange. ASME Trans J Biomech Eng 119(2):179–186CrossRef
go back to reference Uedelhoven W (1994) Quantitative judgement of wearing comfort of hand- and footwear using a hand- and footmodel. In: Proceedings of the sixth international conference on environmental ergonomics (Montebello), pp 154–155 Uedelhoven W (1994) Quantitative judgement of wearing comfort of hand- and footwear using a hand- and footmodel. In: Proceedings of the sixth international conference on environmental ergonomics (Montebello), pp 154–155
go back to reference Uedelhoven W, Kurz B (1998) Reliable Prediction of wearing comfort using improved simulation techniques. In: Proceedings of the eighth international conference on environmental ergonomics (San Diego) Uedelhoven W, Kurz B (1998) Reliable Prediction of wearing comfort using improved simulation techniques. In: Proceedings of the eighth international conference on environmental ergonomics (San Diego)
go back to reference Van Dilla M, Day MR, Siple PA (1949) Special problems of hands. In: Newburgh LH (eds) Physiology of heat regulation and the science of clothing. Saunders, Philadelphia, pp 374–388 Van Dilla M, Day MR, Siple PA (1949) Special problems of hands. In: Newburgh LH (eds) Physiology of heat regulation and the science of clothing. Saunders, Philadelphia, pp 374–388
go back to reference Zimmermann C, Uedelhoven W, Kurz B, Glitz KJ (2006) Prediction of the thermal comfort range of hand wear by thermophysiological simulation. In: Fan J (ed) Thermal Manikins and Modelling 6I3M, Hong Kong, pp 115–118 Zimmermann C, Uedelhoven W, Kurz B, Glitz KJ (2006) Prediction of the thermal comfort range of hand wear by thermophysiological simulation. In: Fan J (ed) Thermal Manikins and Modelling 6I3M, Hong Kong, pp 115–118
Metadata
Title
Thermal comfort range of a military cold protection glove: database by thermophysiological simulation
Authors
Carsten Zimmermann
Wolfgang H. Uedelhoven
Bernhard Kurz
Karl Jochen Glitz
Publication date
01-09-2008
Publisher
Springer-Verlag
Published in
European Journal of Applied Physiology / Issue 2/2008
Print ISSN: 1439-6319
Electronic ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-007-0660-z

Other articles of this Issue 2/2008

European Journal of Applied Physiology 2/2008 Go to the issue