Skip to main content
Top
Published in: Critical Care 1/2005

01-02-2004 | Commentary

The use of bispectral index monitors in paediatric intensive care

Author: Stephen D Playfor

Published in: Critical Care | Issue 1/2005

Login to get access

Abstract

The bispectral index (BIS) is a processed neurophysiological electroencephalographic parameter that may be used to evaluate the depth of sedation in critically ill children. Triltsch and colleagues attempted to correlate BIS scores with a commonly used clinical sedation scoring system. They were able to demonstrate good correlation during deep sedation and in cases where the electrical impedance of the BIS electrodes was lowest. Studies have shown only moderate degrees of correlation between BIS scores and clinical sedation scoring systems. There is currently insufficient evidence to recommend routine monitoring of BIS scores in critically ill children.
Literature
1.
go back to reference Triltsch AE, Nestmann G, Orawa H, Moshirzadeh M, Sander M, Große J, Genähr A, Konertz WJ, Spies CD: Bispectral index versus COMFORT score to determine the level of sedation in pediatric intensive care unit patients: a prospective study. Crit Care 2005, 9: R9-R17. 10.1186/cc2977PubMedCentralCrossRefPubMed Triltsch AE, Nestmann G, Orawa H, Moshirzadeh M, Sander M, Große J, Genähr A, Konertz WJ, Spies CD: Bispectral index versus COMFORT score to determine the level of sedation in pediatric intensive care unit patients: a prospective study. Crit Care 2005, 9: R9-R17. 10.1186/cc2977PubMedCentralCrossRefPubMed
2.
go back to reference Crain N, Slonim A, Pollack MM: Assessing sedation in the pediatric intensive care unit by using BIS and the COMFORT scale. Pediatr Crit Care Med 2002, 3: 11-14. 10.1097/00130478-200201000-00003CrossRefPubMed Crain N, Slonim A, Pollack MM: Assessing sedation in the pediatric intensive care unit by using BIS and the COMFORT scale. Pediatr Crit Care Med 2002, 3: 11-14. 10.1097/00130478-200201000-00003CrossRefPubMed
3.
go back to reference Berkenbosch JW, Fichter CR, Tobias JD: The correlation of the bispectral index monitor with clinical sedation scores during mechanical ventilation in the pediatric intensive care unit. Anesth Analg 2002, 94: 506-511. 10.1097/00000539-200203000-00006CrossRefPubMed Berkenbosch JW, Fichter CR, Tobias JD: The correlation of the bispectral index monitor with clinical sedation scores during mechanical ventilation in the pediatric intensive care unit. Anesth Analg 2002, 94: 506-511. 10.1097/00000539-200203000-00006CrossRefPubMed
4.
go back to reference Aneja R, Heard AM, Fletcher JE, Heard CM: Sedation monitoring of children by the Bispectral Index in the pediatric intensive care unit. Pediatr Crit Care Med 2003, 4: 60-64. 10.1097/00130478-200301000-00012CrossRefPubMed Aneja R, Heard AM, Fletcher JE, Heard CM: Sedation monitoring of children by the Bispectral Index in the pediatric intensive care unit. Pediatr Crit Care Med 2003, 4: 60-64. 10.1097/00130478-200301000-00012CrossRefPubMed
Metadata
Title
The use of bispectral index monitors in paediatric intensive care
Author
Stephen D Playfor
Publication date
01-02-2004
Publisher
BioMed Central
Published in
Critical Care / Issue 1/2005
Electronic ISSN: 1364-8535
DOI
https://doi.org/10.1186/cc3001

Other articles of this Issue 1/2005

Critical Care 1/2005 Go to the issue