The use of a noninvasive hemoglobin monitor for determining fluid distribution and elimination in pediatric patients undergoing minor surgery

Authors: Qingquan Lian, Husong Li, Ruifeng Zeng, Junhui Lang, Wangning Shangguan, Huacheng Liu, Benfu Wang, Peter M. Rodhe, Christer H. Svensen

Published in: Journal of Clinical Monitoring and Computing | Issue 1/2015

Login to get access

Abstract

In pediatric fluid therapy it would be preferable to describe distribution and elimination a fluid bolus based on repetitive hemoglobin (Hb) according to kinetic principles. Pulse CO-Oximetry is a recent advancement in patient monitoring that allows for the continuous noninvasive measurement of Hb (SpHb). The aim of this study was to describe the distribution and elimination of hydroxyethylstarch (HES) 130/0.4 in combination with crystalloids using a noninvasive Hb monitor in two cohorts of young children undergoing minor surgeries under general anesthesia. Two cohorts, 16 children aged 1–3 years and 12 aged 4–6 years, were investigated during anesthesia and minor surgical procedures. They were given a maintenance solution of lactated Ringer’s and a fluid bolus of HES 130/0.4, 6 mL/kg over a period of 20 min. The whole procedure lasted 120 min, and SpHb values were measured every 10 min. The SpHb values were used to calculate plasma dilution, net volume, and mean residence time (MRT) of the infused fluid. A total of 377 measured SpHbs generated individual dilution plots that showed variability, particularly for the older cohort. Distribution and elimination rates of the infused fluid were calculated. Mean dilution plots were generated. There were no significant differences in dilution, net volume or MRT between groups. A non invasive Hb analyzer could be used to calculate fluid distribution. The variability in the data can probably be explained by reactions to anesthetic drugs, variability in measurement technique, variability in generating the complex capillary signals, and individual variability in baseline fluid status. The latter finding is important because this is a prerequisite for perioperative fluid planning for each individual.
Literature
1.
go back to reference Schwarz U. Intraoperative fluid therapy in infants and young children. Anaesthesist. 1999;48(1):41–50.PubMedCrossRef Schwarz U. Intraoperative fluid therapy in infants and young children. Anaesthesist. 1999;48(1):41–50.PubMedCrossRef
2.
go back to reference Standl T, Lochbuehler H, Galli C, Reich A, Dietrich G, Hagemann H. HES 130/0.4 (Voluven) or human albumin in children younger than 2 yr undergoing non-cardiac surgery. A prospective, randomized, open label, multicentre trial. Eur J Anaesthesiol. 2008;25(6):437–45.PubMedCrossRef Standl T, Lochbuehler H, Galli C, Reich A, Dietrich G, Hagemann H. HES 130/0.4 (Voluven) or human albumin in children younger than 2 yr undergoing non-cardiac surgery. A prospective, randomized, open label, multicentre trial. Eur J Anaesthesiol. 2008;25(6):437–45.PubMedCrossRef
3.
go back to reference Hahn RG. Volume kinetics for infusion fluids. Anesthesiology. 2009;113:470–81.CrossRef Hahn RG. Volume kinetics for infusion fluids. Anesthesiology. 2009;113:470–81.CrossRef
4.
go back to reference Shamir MY, Avramovich A, Smaka T. The current status of continuous noninvasive measurement of total, carboxy, and methemoglobin concentration. Anesthesia Analgesia. 2012;114(5):972–8.PubMedCrossRef Shamir MY, Avramovich A, Smaka T. The current status of continuous noninvasive measurement of total, carboxy, and methemoglobin concentration. Anesthesia Analgesia. 2012;114(5):972–8.PubMedCrossRef
5.
go back to reference Frasca D, Dahyot-Fizelier C, Catherine K, Levrat Q, Debaene B, Mimoz O. Accuracy of a continuous noninvasive hemoglobin monitor in intensive care unit patients. Crit Care Med. 2011;39(10):2277–82.PubMedCrossRef Frasca D, Dahyot-Fizelier C, Catherine K, Levrat Q, Debaene B, Mimoz O. Accuracy of a continuous noninvasive hemoglobin monitor in intensive care unit patients. Crit Care Med. 2011;39(10):2277–82.PubMedCrossRef
6.
go back to reference Hahn RG, Li Y, Zdolsek J. Non-invasive monitoring of blood haemoglobin for analysis of fluid volume kinetics. Acta Anaesthesiol Scand. 2010;54(10):1233–40.PubMedCrossRef Hahn RG, Li Y, Zdolsek J. Non-invasive monitoring of blood haemoglobin for analysis of fluid volume kinetics. Acta Anaesthesiol Scand. 2010;54(10):1233–40.PubMedCrossRef
7.
go back to reference Park YH, Lee JH, Song HG, Byon HJ, Kim HS, Kim JT. The accuracy of noninvasive hemoglobin monitoring using the radical-7 pulse CO-oximeter in children undergoing neurosurgery. Anesth Analg. 2012;115(6):1302–7.PubMedCrossRef Park YH, Lee JH, Song HG, Byon HJ, Kim HS, Kim JT. The accuracy of noninvasive hemoglobin monitoring using the radical-7 pulse CO-oximeter in children undergoing neurosurgery. Anesth Analg. 2012;115(6):1302–7.PubMedCrossRef
8.
go back to reference Bergek C, Zdolsek JH, Hahn RG. Accuracy of noninvasive haemoglobin measurement by pulse oximetry depends on the type of infusion fluid. Eur J Anaesthesiol. 2012;29(12):586–92.PubMed Bergek C, Zdolsek JH, Hahn RG. Accuracy of noninvasive haemoglobin measurement by pulse oximetry depends on the type of infusion fluid. Eur J Anaesthesiol. 2012;29(12):586–92.PubMed
9.
go back to reference Nguyen BV, Vincent JL, Nowak E, Coat M, Paleiron N, Gouny P, et al. The accuracy of noninvasive hemoglobin measurement by multiwavelength pulse oximetry after cardiac surgery. Anesth Analg. 2011;113(5):1052–7.PubMedCrossRef Nguyen BV, Vincent JL, Nowak E, Coat M, Paleiron N, Gouny P, et al. The accuracy of noninvasive hemoglobin measurement by multiwavelength pulse oximetry after cardiac surgery. Anesth Analg. 2011;113(5):1052–7.PubMedCrossRef
10.
go back to reference Svensen C, Olsson J, Rodhe P, Boersheim E, Aarsland A, Hahn RG. Arteriovenous differences in plasma dilution and the kinetics of lactated ringer′s solution. Anesth Analg. 2009;108:128–33.PubMedCrossRef Svensen C, Olsson J, Rodhe P, Boersheim E, Aarsland A, Hahn RG. Arteriovenous differences in plasma dilution and the kinetics of lactated ringer′s solution. Anesth Analg. 2009;108:128–33.PubMedCrossRef
11.
go back to reference Karol MD. Mean residence time and the meaning of AUMC/AUC. Biopharm Drug Dispos. 1990;11(2):179–81.PubMedCrossRef Karol MD. Mean residence time and the meaning of AUMC/AUC. Biopharm Drug Dispos. 1990;11(2):179–81.PubMedCrossRef
12.
go back to reference Skelton VA, Wijayasinghe N, Sharafudeen S, Sange A, Parry NS, Junghans C. Evaluation of point-of-care haemoglobin measuring devices: a comparison of Radical-7 pulse Co-Oximetry, HemoCue(®) and laboratory haemoglobin measurements in obstetric patients. Anaesthesia. 2013;68(1):40–5.PubMedCrossRef Skelton VA, Wijayasinghe N, Sharafudeen S, Sange A, Parry NS, Junghans C. Evaluation of point-of-care haemoglobin measuring devices: a comparison of Radical-7 pulse Co-Oximetry, HemoCue(®) and laboratory haemoglobin measurements in obstetric patients. Anaesthesia. 2013;68(1):40–5.PubMedCrossRef
13.
go back to reference Miller RD, Ward TA, Shiboski SC, Cohen NH. A comparison of three methods of hemoglobin monitoring in patients undergoing spine surgery. Anesth Analg. 2011;112(4):858–63.PubMedCrossRef Miller RD, Ward TA, Shiboski SC, Cohen NH. A comparison of three methods of hemoglobin monitoring in patients undergoing spine surgery. Anesth Analg. 2011;112(4):858–63.PubMedCrossRef
14.
go back to reference Macknet MR, Allard M, Applegate RL 2nd, Rook J. The accuracy of noninvasive and continuous total hemoglobin measurement by pulse CO-Oximetry in human subjects undergoing hemodilution. Anesth Analg. 2010;111:1424–6.PubMedCrossRef Macknet MR, Allard M, Applegate RL 2nd, Rook J. The accuracy of noninvasive and continuous total hemoglobin measurement by pulse CO-Oximetry in human subjects undergoing hemodilution. Anesth Analg. 2010;111:1424–6.PubMedCrossRef
15.
go back to reference Morey TE, Gravenstein N, Rice MJ. Let’s think clinically instead of mathematically about device accuracy. Anesth Analg. 2011;113(1):89–91.PubMedCrossRef Morey TE, Gravenstein N, Rice MJ. Let’s think clinically instead of mathematically about device accuracy. Anesth Analg. 2011;113(1):89–91.PubMedCrossRef
16.
go back to reference Sjöstrand F, Rodhe P, Berglund E, Lundström N, Svensen C. The use of a noninvasive hemoglobin monitor for volume kinetic analysis in an emergency room setting. Anesth Analg. 2013;116(2):337–42.PubMedCrossRef Sjöstrand F, Rodhe P, Berglund E, Lundström N, Svensen C. The use of a noninvasive hemoglobin monitor for volume kinetic analysis in an emergency room setting. Anesth Analg. 2013;116(2):337–42.PubMedCrossRef
17.
go back to reference Paul M, Dueck M, Joachim Herrmann H, Holzki J. A randomized, controlled study of fluid management in infants and toddlers during surgery: hydroxyethyl starch 6% (HES 70/0.5) versus lactated Ringer’s solution. Paediatr Anaesth. 2003;13(7):603–8.PubMedCrossRef Paul M, Dueck M, Joachim Herrmann H, Holzki J. A randomized, controlled study of fluid management in infants and toddlers during surgery: hydroxyethyl starch 6% (HES 70/0.5) versus lactated Ringer’s solution. Paediatr Anaesth. 2003;13(7):603–8.PubMedCrossRef
18.
go back to reference Chong Sung K, Kum Suk P, Mi Ja Y, Kyoung Ok K. Effects of intravascular volume therapy using hydroxyethyl starch (130/0.4) on post-operative bleeding and transfusion requirements in children undergoing cardiac surgery: a randomized clinical trial. Acta Anaesthesiol Scand. 2006;50(1):108–11.PubMedCrossRef Chong Sung K, Kum Suk P, Mi Ja Y, Kyoung Ok K. Effects of intravascular volume therapy using hydroxyethyl starch (130/0.4) on post-operative bleeding and transfusion requirements in children undergoing cardiac surgery: a randomized clinical trial. Acta Anaesthesiol Scand. 2006;50(1):108–11.PubMedCrossRef
19.
go back to reference Perner A, Haase N, Guttormsen AB, Tenhunen J, Klemenzson G, Åneman A, et al. Hydroxyethyl starch 130/0.4 versus ringer’s acetate in severe sepsis. N Eng J Med. 2012;367:124–34.CrossRef Perner A, Haase N, Guttormsen AB, Tenhunen J, Klemenzson G, Åneman A, et al. Hydroxyethyl starch 130/0.4 versus ringer’s acetate in severe sepsis. N Eng J Med. 2012;367:124–34.CrossRef
20.
go back to reference Myburgh JA, Finfer S, Bellomo R, Billot L, Cass A, Gattas D, et al. Hydroxyethyl starch or saline for fluid resuscitation in intensive care. N Engl J Med. 2012;367:1901–11.PubMedCrossRef Myburgh JA, Finfer S, Bellomo R, Billot L, Cass A, Gattas D, et al. Hydroxyethyl starch or saline for fluid resuscitation in intensive care. N Engl J Med. 2012;367:1901–11.PubMedCrossRef
21.
go back to reference Akkucuk FG, Kanbak M, Ayhan B, Celebioglu B, Aypar U, et al. The effect of HES (130/0.4) usage as the priming solution on renal function in children undergoing cardiac surgery. Renal Fail. 2013;35(2):210–5 Akkucuk FG, Kanbak M, Ayhan B, Celebioglu B, Aypar U, et al. The effect of HES (130/0.4) usage as the priming solution on renal function in children undergoing cardiac surgery. Renal Fail. 2013;35(2):210–5
Metadata
Title
The use of a noninvasive hemoglobin monitor for determining fluid distribution and elimination in pediatric patients undergoing minor surgery
Authors
Qingquan Lian
Husong Li
Ruifeng Zeng
Junhui Lang
Wangning Shangguan
Huacheng Liu
Benfu Wang
Peter M. Rodhe
Christer H. Svensen
Publication date
01-02-2015
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 1/2015
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-014-9566-6

Other articles of this Issue 1/2015

Journal of Clinical Monitoring and Computing 1/2015 Go to the issue