Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 2/2005

01-03-2005 | Knee

The load of an implanted graft during and after fixation in anterior cruciate ligament reconstruction

Authors: Yukio Yoshihara, Shinichi Yoshiya, Masahiro Kurosaka, Tetsuji Yamamoto, Ryosuke Kuroda, Hirotsugu Muratsu

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 2/2005

Login to get access

Abstract

Although the importance of initial graft load has been discussed in the literature, it has not been confirmed whether a surgeon can provide the desired load to an implanted graft in anterior cruciate ligament reconstruction. The purpose of this study was to compare the set force (initial load given to the graft before fixation) and residual load in the implanted graft using three different fixation techniques. A total of ninety porcine knees were tested using bone–patellar tendon–bone autograft. Each bone–tendon–bone autograft was fixed to the tibia with either the interference-fit screw, fixation post, or button technique. Graft load was monitored during fixation procedures, and for 10 min after fixation. Residual graft load with each fixation technique exhibited unique features. Highest graft load was obtained by the interference-screw fixation technique; however, the graft was usually over-loaded beyond the intended set force with this technique. In the fixation-post technique, the load of the graft increased while the screw was retightened. The graft load in the button-fixation technique was low, probably due to slight slippage of the button. When the graft was fixed under maximum manual tension, the graft loads at completion of fixation for the interference fit screw, fixation post, and button techniques were 116.3, 54.2, and 25.9 N respectively.
Literature
1.
go back to reference Beynnon BD, Johnson RJ, Fleming BC, Renstrom PA, Nichols CE, Pope MH, Haugh LD (1994) The measurement of elongation of anterior cruciate-ligament grafts in vivo. J Bone Joint Surg Am 76:520–531PubMed Beynnon BD, Johnson RJ, Fleming BC, Renstrom PA, Nichols CE, Pope MH, Haugh LD (1994) The measurement of elongation of anterior cruciate-ligament grafts in vivo. J Bone Joint Surg Am 76:520–531PubMed
2.
go back to reference Brown CH, Hecken AT, Hipp JA, Myers ER, Hayes WC (1993) The biomechanics of interference screw fixation of patellar tendon anterior cruciate ligament grafts. Am J Sports Med 21:880–886PubMed Brown CH, Hecken AT, Hipp JA, Myers ER, Hayes WC (1993) The biomechanics of interference screw fixation of patellar tendon anterior cruciate ligament grafts. Am J Sports Med 21:880–886PubMed
3.
go back to reference Burks RT, Leland R (1988) Determination of graft tension before fixation in anterior cruciate ligament reconstruction. Arthroscopy 4:260–266PubMed Burks RT, Leland R (1988) Determination of graft tension before fixation in anterior cruciate ligament reconstruction. Arthroscopy 4:260–266PubMed
4.
go back to reference Bylski-Austrow DI, Grood DI, Hefzy MS, Holden JP, Butler DL (1990) Anterior cruciate ligament replacements: a mechanical study of femoral attachment location, flexion angle at loading, and initial load. J Orthop Res 8:522–531PubMed Bylski-Austrow DI, Grood DI, Hefzy MS, Holden JP, Butler DL (1990) Anterior cruciate ligament replacements: a mechanical study of femoral attachment location, flexion angle at loading, and initial load. J Orthop Res 8:522–531PubMed
5.
go back to reference Cunningham R, West JR, Greis PE, Burks RT (2002) A survey of the tension applied to a doubled hamstring tendon graft for reconstruction of the anterior cruciate ligament. Arthroscopy 18:983–988PubMed Cunningham R, West JR, Greis PE, Burks RT (2002) A survey of the tension applied to a doubled hamstring tendon graft for reconstruction of the anterior cruciate ligament. Arthroscopy 18:983–988PubMed
6.
go back to reference Frank CB, Jackson DW (1997) The science of reconstruction of the anterior cruciate ligament. J Bone Joint Surg Br 79:1556–1576 Frank CB, Jackson DW (1997) The science of reconstruction of the anterior cruciate ligament. J Bone Joint Surg Br 79:1556–1576
7.
go back to reference Graf BK, Vanderby R Jr, Ulm MJ, Rogalski RP, Thielke RJ (1994) Effect of preconditioning on the viscoelastic response of primate patellar tendon. Arthroscopy 10:90–96PubMed Graf BK, Vanderby R Jr, Ulm MJ, Rogalski RP, Thielke RJ (1994) Effect of preconditioning on the viscoelastic response of primate patellar tendon. Arthroscopy 10:90–96PubMed
8.
go back to reference Howell SM, Wallace MP, Hull ML, Deutsch ML (1999) Evaluation of the single-incision arthroscopic technique for anterior cruciate ligament replacement. A study of tibial tunnel placement, intraoperative graft tension, and stability. Am J Sports Med 27:284–293PubMed Howell SM, Wallace MP, Hull ML, Deutsch ML (1999) Evaluation of the single-incision arthroscopic technique for anterior cruciate ligament replacement. A study of tibial tunnel placement, intraoperative graft tension, and stability. Am J Sports Med 27:284–293PubMed
9.
go back to reference Hulstyn M, Abate FS, Walsh WR (1993) Biomechanical evaluation of interference screw fixation in a bovine patellar bone–tendon–bone autograft complex for anterior cruciate ligament reconstruction. Arthroscopy 9:417–424PubMed Hulstyn M, Abate FS, Walsh WR (1993) Biomechanical evaluation of interference screw fixation in a bovine patellar bone–tendon–bone autograft complex for anterior cruciate ligament reconstruction. Arthroscopy 9:417–424PubMed
10.
go back to reference Hunter RE, Lew WD, Lewis JL, Kowalczyk C, Settle W (1990) Graft force-setting technique in reconstruction of the anterior cruciate ligament. Am J Sports Med 18:12–19PubMed Hunter RE, Lew WD, Lewis JL, Kowalczyk C, Settle W (1990) Graft force-setting technique in reconstruction of the anterior cruciate ligament. Am J Sports Med 18:12–19PubMed
11.
go back to reference Ishibashi Y, Rudy TW, Livesay GA et al (1997) The effect of anterior cruciate ligament graft fixation site at the tibia on knee stability: evaluation using a robotic testing system. Arthroscopy 13:177–182CrossRefPubMed Ishibashi Y, Rudy TW, Livesay GA et al (1997) The effect of anterior cruciate ligament graft fixation site at the tibia on knee stability: evaluation using a robotic testing system. Arthroscopy 13:177–182CrossRefPubMed
12.
go back to reference Johnson GA. Tramaglini DM. Levine RE et al (1994) Tensile and viscoelastic properties of human patellar tendon. J Orthop Res 12:796–803PubMed Johnson GA. Tramaglini DM. Levine RE et al (1994) Tensile and viscoelastic properties of human patellar tendon. J Orthop Res 12:796–803PubMed
13.
go back to reference Jomha NM, Raso J, Leung P (1993) Effect of varying angles on the pullout strength of interference screw fixation. Arthroscopy 9:580–583PubMed Jomha NM, Raso J, Leung P (1993) Effect of varying angles on the pullout strength of interference screw fixation. Arthroscopy 9:580–583PubMed
14.
go back to reference Kurosaka M, Yoshiya S, Andrish JT (1987) A biomechanical comparison of different surgical techniques of graft fixation in anterior cruciate reconstruction. Am J Sports Med 15:225–229PubMed Kurosaka M, Yoshiya S, Andrish JT (1987) A biomechanical comparison of different surgical techniques of graft fixation in anterior cruciate reconstruction. Am J Sports Med 15:225–229PubMed
15.
go back to reference Matthews LS, Soffer SR (1989) Pitfalls in the use of interference screw for anterior cruciate ligament reconstruction: a brief report. Arthroscopy 5:225–226PubMed Matthews LS, Soffer SR (1989) Pitfalls in the use of interference screw for anterior cruciate ligament reconstruction: a brief report. Arthroscopy 5:225–226PubMed
16.
go back to reference Melby A III, Noble JS, Askew MJ, Boom AA, Hurst FW (1991) The effects of graft loading on the laxity and kinematics of the anterior cruciate ligament reconstructed knee. Arthroscopy 7:257–266PubMed Melby A III, Noble JS, Askew MJ, Boom AA, Hurst FW (1991) The effects of graft loading on the laxity and kinematics of the anterior cruciate ligament reconstructed knee. Arthroscopy 7:257–266PubMed
17.
go back to reference Nabors ED, Richmond JC, Vannah WM, McConville OR (1995) Anterior cruciate ligament graft tensioning in full extension. Am J Sports Med 23:488–492PubMed Nabors ED, Richmond JC, Vannah WM, McConville OR (1995) Anterior cruciate ligament graft tensioning in full extension. Am J Sports Med 23:488–492PubMed
18.
go back to reference Noyes FR, Butler DL, Grood ES, Zernicke RF, Hefzy MS (1984) Biomechanical analysis of human ligamaent grafts used in knee-ligament repairs and reconstructions. J Bone Joint Surg Am 66:344–352PubMed Noyes FR, Butler DL, Grood ES, Zernicke RF, Hefzy MS (1984) Biomechanical analysis of human ligamaent grafts used in knee-ligament repairs and reconstructions. J Bone Joint Surg Am 66:344–352PubMed
19.
go back to reference Numazaki H, Tohyama H, Nakano H, Kikuchi S, Yasuda K (2002) The effect of initial graft tension in anterior cruciate ligament reconstruction on the mechanical behaviors of the femur–graft–tibia complex during cyclic loading. Am J Sports Med 30:800–805PubMed Numazaki H, Tohyama H, Nakano H, Kikuchi S, Yasuda K (2002) The effect of initial graft tension in anterior cruciate ligament reconstruction on the mechanical behaviors of the femur–graft–tibia complex during cyclic loading. Am J Sports Med 30:800–805PubMed
20.
go back to reference Pierz K, Baltz M, Fulkerson J (1995) The effect of Kurosaka screw divergence on the holding strength of bone–tendon–bone grafts. Am J Sports Med 23:332–335PubMed Pierz K, Baltz M, Fulkerson J (1995) The effect of Kurosaka screw divergence on the holding strength of bone–tendon–bone grafts. Am J Sports Med 23:332–335PubMed
21.
go back to reference Ringer GW, Wayne JS, Smith JP III, Zuelzer WA (1998) In vivo graft load measurement following anterior cruciate ligament reconstruction. Trans Orthop Res Soc 23:68 Ringer GW, Wayne JS, Smith JP III, Zuelzer WA (1998) In vivo graft load measurement following anterior cruciate ligament reconstruction. Trans Orthop Res Soc 23:68
22.
go back to reference Rowden NJ, Sher D, Rogers GJ, Schindhelm K (1997) Anterior cruciate ligament graft fixation: initial comparison of patellar tendon and semitendinosus autografts in young fresh cadavers. Am J Sports Med 25:472–478PubMed Rowden NJ, Sher D, Rogers GJ, Schindhelm K (1997) Anterior cruciate ligament graft fixation: initial comparison of patellar tendon and semitendinosus autografts in young fresh cadavers. Am J Sports Med 25:472–478PubMed
23.
go back to reference Stewart NJ, Engebretsen L, Lewis JL, Lindquist C, Lew WD (1993) Maintenance of set force in anterior cruciate ligament grafts. J Orthop Res 11:149–153PubMed Stewart NJ, Engebretsen L, Lewis JL, Lindquist C, Lew WD (1993) Maintenance of set force in anterior cruciate ligament grafts. J Orthop Res 11:149–153PubMed
24.
go back to reference To JT, Howell SM, Hull ML (1999) Contributions of femoral fixation methods to the stiffness of anterior cruciate ligament replacements at implantation. Arthroscopy 15:379–387PubMed To JT, Howell SM, Hull ML (1999) Contributions of femoral fixation methods to the stiffness of anterior cruciate ligament replacements at implantation. Arthroscopy 15:379–387PubMed
25.
go back to reference van Kampen A, Wymenga AB, van der Heide HJL, Bakens HJAM (1998) The effect of different graft tensioning in anterior cruciate ligament reconstruction: a prospective randomized study. Arthroscopy 14:845–850PubMed van Kampen A, Wymenga AB, van der Heide HJL, Bakens HJAM (1998) The effect of different graft tensioning in anterior cruciate ligament reconstruction: a prospective randomized study. Arthroscopy 14:845–850PubMed
26.
go back to reference Yasuda K, Tsujino J, Tanabe Y, Kaneda K (1997) Effects of initial graft tension on clinical outcome after anterior cruciate ligament reconstruction: autogenous doubled hamstring tendons connected in series with polyester tapes. Am J Sports Med 25:99–105PubMed Yasuda K, Tsujino J, Tanabe Y, Kaneda K (1997) Effects of initial graft tension on clinical outcome after anterior cruciate ligament reconstruction: autogenous doubled hamstring tendons connected in series with polyester tapes. Am J Sports Med 25:99–105PubMed
27.
go back to reference Yoshiya S, Andrish JT, Manley MT, Bauer TW (1987) Graft tension in anterior cruciate ligament reconstruction: an in vivo study in dogs. Am J Sports Med 15:464–470PubMed Yoshiya S, Andrish JT, Manley MT, Bauer TW (1987) Graft tension in anterior cruciate ligament reconstruction: an in vivo study in dogs. Am J Sports Med 15:464–470PubMed
28.
go back to reference Yoshiya S, Kurosaka M, Ouchi K, Kuroda R, Mizuno K (2002) Graft tension and knee stability after anterior cruciate ligament reconstruction. Clin Orthop 394:154–160PubMed Yoshiya S, Kurosaka M, Ouchi K, Kuroda R, Mizuno K (2002) Graft tension and knee stability after anterior cruciate ligament reconstruction. Clin Orthop 394:154–160PubMed
Metadata
Title
The load of an implanted graft during and after fixation in anterior cruciate ligament reconstruction
Authors
Yukio Yoshihara
Shinichi Yoshiya
Masahiro Kurosaka
Tetsuji Yamamoto
Ryosuke Kuroda
Hirotsugu Muratsu
Publication date
01-03-2005
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 2/2005
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-004-0534-4

Other articles of this Issue 2/2005

Knee Surgery, Sports Traumatology, Arthroscopy 2/2005 Go to the issue

Announcements

March 2005