Skip to main content
Top
Published in: European Journal of Orthopaedic Surgery & Traumatology 1/2016

Open Access 01-01-2016 | Original Article • CERVICAL SPINE - PROSTHESIS

The innovative viscoelastic CP ESP cervical disk prosthesis with six degrees of freedom: biomechanical concepts, development program and preliminary clinical experience

Authors: Jean-yves Lazennec, Alain Aaron, Olivier Ricart, Jean Patrick Rakover

Published in: European Journal of Orthopaedic Surgery & Traumatology | Issue 1/2016

Login to get access

Abstract

The viscoelastic cervical disk prosthesis ESP is an innovative one-piece deformable but cohesive interbody spacer. It is an evolution of the LP ESP lumbar disk implanted since 2006. CP ESP provides six full degrees of freedom about the three axes including shock absorbtion. The prosthesis geometry allows limited rotation and translation with resistance to motion (elastic return property) aimed at avoiding overload of the posterior facets. The rotation center can vary freely during motion. The concept of the ESP prosthesis is fundamentally different from that of the devices currently used in the cervical spine. The originality of the concept of the ESP® prosthesis led to innovative and intense testing to validate the adhesion of the viscoelastic component of the disk on the titanium endplates and to assess the mechanical properties of the PCU cushion. The preliminary clinical and radiological results with 2-year follow-up are encouraging for pain, function and kinematic behavior (range of motion and evolution of the mean centers of rotation). In this series, we did not observe device-related specific complications, misalignment, instability or ossifications. Additional studies and longer patient follow-up are needed to assess long-term reliability of this innovative implant.
Literature
2.
go back to reference Goffin J, Geusens E, Vantomme N, Quintens E, Waerzeggers Y, Depreitere B, Van Calenbergh F, van Loon J (2004) Long-term follow-up after interbody fusion of the cervical spine. J Spinal Disord Tech 17(2):79–85PubMedCrossRef Goffin J, Geusens E, Vantomme N, Quintens E, Waerzeggers Y, Depreitere B, Van Calenbergh F, van Loon J (2004) Long-term follow-up after interbody fusion of the cervical spine. J Spinal Disord Tech 17(2):79–85PubMedCrossRef
3.
go back to reference Hilibrand AS, Carlson GD, Palumbo MA, Jones PK, Bohlman HH (1999) Radiculopathy and myelopathy at segments adjacent to the site of a previous anterior cervical arthrodesis. J Bone Joint Surg Am 81(4):519–528PubMed Hilibrand AS, Carlson GD, Palumbo MA, Jones PK, Bohlman HH (1999) Radiculopathy and myelopathy at segments adjacent to the site of a previous anterior cervical arthrodesis. J Bone Joint Surg Am 81(4):519–528PubMed
4.
go back to reference Dmitriev AE, Cunningham BW, Hu N, Sell G, Vigna F, McAfee PC (2005) Adjacent level intradiscal pressure and segmental kinematics following a cervical total disc arthroplasty: an in vitro human cadaveric model. Spine (Phila Pa 1976) 30(10):1165–1172CrossRef Dmitriev AE, Cunningham BW, Hu N, Sell G, Vigna F, McAfee PC (2005) Adjacent level intradiscal pressure and segmental kinematics following a cervical total disc arthroplasty: an in vitro human cadaveric model. Spine (Phila Pa 1976) 30(10):1165–1172CrossRef
5.
go back to reference Chang UK, Kim DH, Lee MC, Willenberg R, Kim SH, Lim J (2007) Range of motion change after cervical arthroplasty with ProDisc-C and prestige artificial discs compared with anterior cervical discectomy and fusion. J Neurosurg Spine 7(1):40–46. doi:10.3171/SPI-07/07/040 PubMedCrossRef Chang UK, Kim DH, Lee MC, Willenberg R, Kim SH, Lim J (2007) Range of motion change after cervical arthroplasty with ProDisc-C and prestige artificial discs compared with anterior cervical discectomy and fusion. J Neurosurg Spine 7(1):40–46. doi:10.​3171/​SPI-07/​07/​040 PubMedCrossRef
7.
go back to reference Fuller DA, Kirkpatrick JS, Emery SE, Wilber RG, Davy DT (1998) A kinematic study of the cervical spine before and after segmental arthrodesis. Spine (Phila Pa 1976) 23(15):1649–1656CrossRef Fuller DA, Kirkpatrick JS, Emery SE, Wilber RG, Davy DT (1998) A kinematic study of the cervical spine before and after segmental arthrodesis. Spine (Phila Pa 1976) 23(15):1649–1656CrossRef
8.
go back to reference Katsuura A, Hukuda S, Saruhashi Y, Mori K (2001) Kyphotic malalignment after anterior cervical fusion is one of the factors promoting the degenerative process in adjacent intervertebral levels. Eur Spine J 10(4):320–324PubMedPubMedCentralCrossRef Katsuura A, Hukuda S, Saruhashi Y, Mori K (2001) Kyphotic malalignment after anterior cervical fusion is one of the factors promoting the degenerative process in adjacent intervertebral levels. Eur Spine J 10(4):320–324PubMedPubMedCentralCrossRef
12.
go back to reference Liu B, Liu Z, VanHoof T, Kalala J, Zeng Z, Lin X (2014) Kinematic study of the relation between the instantaneous center of rotation and degenerative changes in the cervical intervertebral disc. Eur Spine J 23(11):2307–2313. doi:10.1007/s00586-014-3431-7 PubMedCrossRef Liu B, Liu Z, VanHoof T, Kalala J, Zeng Z, Lin X (2014) Kinematic study of the relation between the instantaneous center of rotation and degenerative changes in the cervical intervertebral disc. Eur Spine J 23(11):2307–2313. doi:10.​1007/​s00586-014-3431-7 PubMedCrossRef
13.
18.
20.
go back to reference Rousseau MA, Cottin P, Levante S, Nogier A, Lazennec JY, Skalli W (2008) In vivo kinematics of two types of ball-and-socket cervical disc replacements in the sagittal plane: cranial versus caudal geometric center. Spine (Phila Pa 1976) 33(1):E6–E9. doi:10.1097/BRS.0b013e31815e5dce CrossRef Rousseau MA, Cottin P, Levante S, Nogier A, Lazennec JY, Skalli W (2008) In vivo kinematics of two types of ball-and-socket cervical disc replacements in the sagittal plane: cranial versus caudal geometric center. Spine (Phila Pa 1976) 33(1):E6–E9. doi:10.​1097/​BRS.​0b013e31815e5dce​ CrossRef
28.
go back to reference Kurtz SM, Siskey R, Reitman M (2010) Accelerated aging, natural aging, and small punch testing of gamma-air sterilized polycarbonate urethane acetabular components. J Biomed Mater Res B Appl Biomater 93(2):442–447. doi:10.1002/jbm.b.31601 PubMedCrossRef Kurtz SM, Siskey R, Reitman M (2010) Accelerated aging, natural aging, and small punch testing of gamma-air sterilized polycarbonate urethane acetabular components. J Biomed Mater Res B Appl Biomater 93(2):442–447. doi:10.​1002/​jbm.​b.​31601 PubMedCrossRef
29.
Metadata
Title
The innovative viscoelastic CP ESP cervical disk prosthesis with six degrees of freedom: biomechanical concepts, development program and preliminary clinical experience
Authors
Jean-yves Lazennec
Alain Aaron
Olivier Ricart
Jean Patrick Rakover
Publication date
01-01-2016
Publisher
Springer Paris
Published in
European Journal of Orthopaedic Surgery & Traumatology / Issue 1/2016
Print ISSN: 1633-8065
Electronic ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-015-1695-1

Other articles of this Issue 1/2016

European Journal of Orthopaedic Surgery & Traumatology 1/2016 Go to the issue