Abstract

Purpose

The Vibrant Soundbridge (VSB) is an established active-middle-ear-implant for patients with moderate-to-profound hearing-loss. This surgery is referred to as “Vibroplasty”. Sufficient transfer of the VSB’s floating-mass-transducers (FMT) energy to the inner ear is a crucial factor influencing the coupling-quality (CQ). However, assessing CQ is hamper by two issues: the method of CQ-assessment itself and the method of FMT-fixation during Vibroplasty.

Methods

This prospective study explored the influence of intraoperative auditory-brainstem-response (+ ABR) measurements and various fixation methods on postoperative CQ after Vibroplasty as compared to matched-patients after Vibroplasty without intraoperative ABR (-ABR). Propensity-score-matching was performed based on preoperative bone-conduction-pure-tone-average-3 (BC-PTA3) at 1-, 2- and 4 kHz. Primary outcome parameters were postoperative CQ-PTA3, intraoperative ABR threshold for various fixation methods and postoperative BC-PTA3.

Results

A total of 28 patients were included, of which 14 were + ABR. Preoperative BC-PTA3, sex, age, and number of previous surgeries did not differ significantly between groups (all p > 0.301). Mean postoperative CQ-PTA3 was significantly better for + ABR (1.8 vs. 12.3 dB-HL; p = 0.006). Mean intraoperative ABR threshold was superior for cartilage-counter-bearing and cartilage-housing compared to additional fixation with injectable-platelet-rich- fibrin (53 vs. 56 & 57 dB-HL, respectively; p = 0.04; η2 = 0.33). Mean postoperative BC-PTA3 did not significantly differ between patients (41.4 vs. 41.8 dB-HL; p = 0.77). A total of 7% of the patients required intraoperative readjustment of the FMT based on unsatisfactory intraoperative ABR threshold.

Conclusion

Intraoperative ABR measurement resulted in significantly better postoperative CQ. Cartilage-counter-bearing and cartilage-housing were observed to have superior CQ. A total of 7% of the patients could be spared revision-Vibroplasty due to intraoperative ABR measurement.
Literature
5.
go back to reference Dazert S, Shehata-Dieler WE, Dieler R, Helms J (2000) ["Vibrant Soundbridge" middle ear implant for auditory rehabilitation in sensory hearing loss. I. Clinical aspects, indications and initial results]. Laryngorhinootologie 79(8):459–64. DOI: https://doi.org/10.1055/s-2000-5912. Dazert S, Shehata-Dieler WE, Dieler R, Helms J (2000) ["Vibrant Soundbridge" middle ear implant for auditory rehabilitation in sensory hearing loss. I. Clinical aspects, indications and initial results]. Laryngorhinootologie 79(8):459–64. DOI: https://​doi.​org/​10.​1055/​s-2000-5912.
6.
go back to reference Luetje CM, Brackman D, Balkany TJ, Maw J, Baker RS, Kelsall D, Backous D, Miyamoto R, Parisier S, Arts A (2002) Phase III clinical trial results with the Vibrant Soundbridge implantable middle ear hearing device: a prospective controlled multicenter study. Otolaryngol Head Neck Surg 126(2):97–107. https://doi.org/10.1067/mhn.2002.122182CrossRefPubMed Luetje CM, Brackman D, Balkany TJ, Maw J, Baker RS, Kelsall D, Backous D, Miyamoto R, Parisier S, Arts A (2002) Phase III clinical trial results with the Vibrant Soundbridge implantable middle ear hearing device: a prospective controlled multicenter study. Otolaryngol Head Neck Surg 126(2):97–107. https://​doi.​org/​10.​1067/​mhn.​2002.​122182CrossRefPubMed
12.
go back to reference Fröhlich L, Rahne T, Plontke SK, Oberhoffner T, Dahl R, Mlynski R, Dziemba O, Aristeidou A, Gadyuchko M, Koscielny S, Hoth S, Kropp MH, Mir-Salim P, Müller A (2021) Intraoperative quantification of floating mass transducer coupling quality in active middle ear implants: a multicenter study. Eur Arch Otorhinolaryngol 278(7):2277–2288. https://doi.org/10.1007/s00405-020-06313-zCrossRefPubMed Fröhlich L, Rahne T, Plontke SK, Oberhoffner T, Dahl R, Mlynski R, Dziemba O, Aristeidou A, Gadyuchko M, Koscielny S, Hoth S, Kropp MH, Mir-Salim P, Müller A (2021) Intraoperative quantification of floating mass transducer coupling quality in active middle ear implants: a multicenter study. Eur Arch Otorhinolaryngol 278(7):2277–2288. https://​doi.​org/​10.​1007/​s00405-020-06313-zCrossRefPubMed
18.
24.
go back to reference Zahner T, Mlynski R, Löwenheim H, Beutner D, Hagen R, Ernst A, Zehlicke T, Kühne H, Friese N, Tropitzsch A, Luers JC, Todt I, Hüttenbrink KB (2018) Long-term outcomes of Vibroplasty coupler implantations to treat mixed/conductive hearing loss. Audiol Neurootol 23(6):316–325. https://doi.org/10.1159/000495560CrossRef Zahner T, Mlynski R, Löwenheim H, Beutner D, Hagen R, Ernst A, Zehlicke T, Kühne H, Friese N, Tropitzsch A, Luers JC, Todt I, Hüttenbrink KB (2018) Long-term outcomes of Vibroplasty coupler implantations to treat mixed/conductive hearing loss. Audiol Neurootol 23(6):316–325. https://​doi.​org/​10.​1159/​000495560CrossRef
25.
go back to reference Rahne T, Skarzynski PH, Hagen R, Radeloff A, Lassaletta L, Barbara M, Plontke SK, Mlynski R (2020) A retrospective European multicenter analysis of the functional outcomes after active middle ear implant surgery using the third generation Vibroplasty couplers. Eur Arch Otorhinolarynol 278(1):67–75. https://doi.org/10.1007/s00405-020-06064-xCrossRef Rahne T, Skarzynski PH, Hagen R, Radeloff A, Lassaletta L, Barbara M, Plontke SK, Mlynski R (2020) A retrospective European multicenter analysis of the functional outcomes after active middle ear implant surgery using the third generation Vibroplasty couplers. Eur Arch Otorhinolarynol 278(1):67–75. https://​doi.​org/​10.​1007/​s00405-020-06064-xCrossRef
Metadata
Title
The influence of intraoperative auditory brainstem responses on vibroplasty coupling-quality and analysis of the impact of different fixation steps on the coupling
Authors
Daniel Dejaco
David Riedl
Timo Maria Gottfried
Matthias Santer
Annette Runge
Josef Seebacher
Philipp Zelger
Bicego Lia
Schmutzhard Joachim
Publication date
13-07-2023
Publisher
Springer Berlin Heidelberg
Published in
European Archives of Oto-Rhino-Laryngology / Issue 1/2024
Print ISSN: 0937-4477
Electronic ISSN: 1434-4726
DOI
https://doi.org/10.1007/s00405-023-08103-9

Other articles of this Issue 1/2024

European Archives of Oto-Rhino-Laryngology 1/2024 Go to the issue