Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2006

Open Access 01-12-2006 | Research article

The implications of 18F-FDG PET for the diagnosis of endoprosthetic loosening and infection in hip and knee arthroplasty: Results from a prospective, blinded study

Authors: K-St Delank, M Schmidt, JW-P Michael, M Dietlein, H Schicha, P Eysel

Published in: BMC Musculoskeletal Disorders | Issue 1/2006

Login to get access

Abstract

Background

The most frequent complications of joint arthroplasty are septic or aseptic loosening of endoprostheses. Preoperative differentiation is essential, since very different treatment methods result from the diagnoses. The aim of the current study was to evaluate the clinical value of 18F-Fluoro-deoxyglucose positron emission tomography (18F-FDG PET) as a diagnostic modality for inflammation and loosening in hip and knee joint prostheses.

Methods

18F-FDG-PET examinations and multiphase bone scan were performed on hip and knee endoprostheses in 27 patients prior to revision surgical procedures planned for prosthetic loosening. Intact prostheses were found at the opposite site in some patients so that additional 9 joints could be examined with the field of view of 18F-FDG PET. Verification and valuation of the PET and scintigraphic image findings were conducted by comparing them with information combined from intraoperative findings, histopathology, and microbiological investigations.

Results

Evidence of loosening was correctly determined in 76.4% of cases using 18F-FDG-PET, and in 75% of cases using bone scan. The detection of periprosthetic inflammation using 18F-FDG-PET had a sensitivity of 100% for septic cases and of 45.5% in cases of increased abrasion and aseptic foreign-body reactions. However, reliable differentiation between abrasion-induced and bacterial-caused inflammation was not possible using 18F-FDG-PET.

Conclusion

18F-Fluoro-deoxyglucose positron emission tomography (18F-FDG-PET) allows reliable prediction of peri-prosthetic septical inflammatory tissue reactions. Because of the high sensitivity of this method, a negative PET result in the setting of a diagnostically unclear situation eliminates the need for revision surgery. In contrast, a positive PET result gives no clear differentiation regarding the cause of inflammation.
Appendix
Available only for authorised users
Literature
1.
go back to reference Temmermann OPP, Raijmakers PGHM, David EFL, Pijpers R, Molenaar MA, Hoekstra OS, Berkhof J, Manoliu RA, Teule GJJ, Heyligers IC: A comparison of radiographic and scintigraphic techniques to assess aseptic loosening of the acetabular component in a total hip replacement. J Bone Joint Surg Am. 2004, 86-A: 2456-2462. Temmermann OPP, Raijmakers PGHM, David EFL, Pijpers R, Molenaar MA, Hoekstra OS, Berkhof J, Manoliu RA, Teule GJJ, Heyligers IC: A comparison of radiographic and scintigraphic techniques to assess aseptic loosening of the acetabular component in a total hip replacement. J Bone Joint Surg Am. 2004, 86-A: 2456-2462.
2.
go back to reference De Winter F, van de Wiele C, de Clercq D, Vogelaers D, de Bondt P, Dierckx RA: Aseptic loosening of a knee prosthesis as imaged on FDG positron emission tomography. Clin Nucl Med. 2000, 25: 923-10.1097/00003072-200011000-00017.CrossRefPubMed De Winter F, van de Wiele C, de Clercq D, Vogelaers D, de Bondt P, Dierckx RA: Aseptic loosening of a knee prosthesis as imaged on FDG positron emission tomography. Clin Nucl Med. 2000, 25: 923-10.1097/00003072-200011000-00017.CrossRefPubMed
3.
go back to reference Van Acker F, Nuyts J, Maes A, Vanquickenborne B, Stuyck J, Bellemans J, Vleugels S, Bormans G, Mortelmans L: FDG-PET, 99mTc-HMPAO white blood cell SPET and bone scintigraphy in the evaluation of painful total knee arthroplasties. Eur J Nucl Med. 2001, 28: 1496-1504. 10.1007/s002590100603.CrossRefPubMed Van Acker F, Nuyts J, Maes A, Vanquickenborne B, Stuyck J, Bellemans J, Vleugels S, Bormans G, Mortelmans L: FDG-PET, 99mTc-HMPAO white blood cell SPET and bone scintigraphy in the evaluation of painful total knee arthroplasties. Eur J Nucl Med. 2001, 28: 1496-1504. 10.1007/s002590100603.CrossRefPubMed
4.
go back to reference Reinartz P, Mumme T, Hermanns B, Cremerius U, Wirtz DC, Schaefer WM, Niethard FU, Buell U: Radionuclide imaging of the painful hip arthroplasty: Positron-emission Tomography versus triple-phase bone scanning. J Bone Joint Surg Br. 2005, 87-B: 465-470. 10.1302/0301-620X.87B4.14954.CrossRef Reinartz P, Mumme T, Hermanns B, Cremerius U, Wirtz DC, Schaefer WM, Niethard FU, Buell U: Radionuclide imaging of the painful hip arthroplasty: Positron-emission Tomography versus triple-phase bone scanning. J Bone Joint Surg Br. 2005, 87-B: 465-470. 10.1302/0301-620X.87B4.14954.CrossRef
5.
go back to reference Cremerius U, Mumme T, Reinartz P, Wirtz D, Niethard FU., Büll U: Analyse der 18F-FDG Speichermuster in der PET zur Diagnostik von septischer und aseptischer Lockerung bei Totalendoprothesen des Hüftgelenks. Nuklearmedizin. 2003, 42: 234-239.PubMed Cremerius U, Mumme T, Reinartz P, Wirtz D, Niethard FU., Büll U: Analyse der 18F-FDG Speichermuster in der PET zur Diagnostik von septischer und aseptischer Lockerung bei Totalendoprothesen des Hüftgelenks. Nuklearmedizin. 2003, 42: 234-239.PubMed
6.
go back to reference Wienhard K, Eriksson L, Grootoonk S, Casey M, Pietrzyk U, Heiss WD: Performance evaluation of the positron scanner ECAT EXACT. J Comput Assist Tomogr. 1992, 16: 804-813.CrossRefPubMed Wienhard K, Eriksson L, Grootoonk S, Casey M, Pietrzyk U, Heiss WD: Performance evaluation of the positron scanner ECAT EXACT. J Comput Assist Tomogr. 1992, 16: 804-813.CrossRefPubMed
7.
go back to reference Hamacher K, Coenen HH, Stoecklin G: Efficient stereospecific synthesis of no-carrier-added 2-[18F]-fluoro-2-deoxy-D-glucose using aminopolyether supported nucleophilic substitution. J Nucl Med. 1986, 27: 235-238.PubMed Hamacher K, Coenen HH, Stoecklin G: Efficient stereospecific synthesis of no-carrier-added 2-[18F]-fluoro-2-deoxy-D-glucose using aminopolyether supported nucleophilic substitution. J Nucl Med. 1986, 27: 235-238.PubMed
8.
go back to reference Neut D, van Horn JR, van Kooten TG, van der Mei HC, Busscher HJ: Detection of biomaterial-associated infections in orthopaedic joint implants. Clin Orthop. 2003, 413: 261-268.CrossRefPubMed Neut D, van Horn JR, van Kooten TG, van der Mei HC, Busscher HJ: Detection of biomaterial-associated infections in orthopaedic joint implants. Clin Orthop. 2003, 413: 261-268.CrossRefPubMed
9.
go back to reference DeLee JG, Charnley J: Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop. 1976, 121: 20-32.PubMed DeLee JG, Charnley J: Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop. 1976, 121: 20-32.PubMed
10.
go back to reference Gruen TA, McNiece JM, Amsturtz HC: "Modes of failure" of cemented stem type femoral components: a radiographic analysis of loosening. Clin Orthop. 1979, 141: 17-29.PubMed Gruen TA, McNiece JM, Amsturtz HC: "Modes of failure" of cemented stem type femoral components: a radiographic analysis of loosening. Clin Orthop. 1979, 141: 17-29.PubMed
11.
go back to reference Gunther R, Morawietz L, Gehrke T, Frommelt L, Kaps C, Krenn V: Inflammatory reactions in the wear particle induced and infectious periprosthetic membrane of loosened hip- and knee endoprostheses: pathogenetic relevance of differentially expressed genes cd9, cd11b, cd18, cd52 and pdgfrbeta. Orthopade. 2005, 34 (1): 55-64. 10.1007/s00132-004-0709-1.CrossRefPubMed Gunther R, Morawietz L, Gehrke T, Frommelt L, Kaps C, Krenn V: Inflammatory reactions in the wear particle induced and infectious periprosthetic membrane of loosened hip- and knee endoprostheses: pathogenetic relevance of differentially expressed genes cd9, cd11b, cd18, cd52 and pdgfrbeta. Orthopade. 2005, 34 (1): 55-64. 10.1007/s00132-004-0709-1.CrossRefPubMed
12.
go back to reference Rennen HJ, Corstens FH, Oyen WJ, Boerman OC: New concepts in infection/inflammation imaging. Q J Nucl Med. 2001, 45 (2): 167-73.PubMed Rennen HJ, Corstens FH, Oyen WJ, Boerman OC: New concepts in infection/inflammation imaging. Q J Nucl Med. 2001, 45 (2): 167-73.PubMed
13.
go back to reference De Winter F, van de Wiele C, Vogelaers D, de Smet K, Verdonk R, Dierckx RA: Fluorine-18 Fluorodeoxyglucose-Positron emission tomography: A highly accurate imaging modality for the diagnosis of chronic musculoskeletal infections. J Bone Joint Surg Am. 2001, 83-A: 651-660.PubMed De Winter F, van de Wiele C, Vogelaers D, de Smet K, Verdonk R, Dierckx RA: Fluorine-18 Fluorodeoxyglucose-Positron emission tomography: A highly accurate imaging modality for the diagnosis of chronic musculoskeletal infections. J Bone Joint Surg Am. 2001, 83-A: 651-660.PubMed
14.
go back to reference Morawietz L, Gehrke T, Classen RA, Barden B, Otto M, Hansen T, Aigner T, Stiehl P, Neidel J, Schroder JH, Frommelt L, Schubert T, Meyer-Scholten C, Konig A, Strobel P, Rader ChP, Kirschner S, Lintner F, Ruther W, Skwara A, Bos I, Kriegsmann J, Krenn V: Proposal for the classification of the periprosthetic membrane from loosened hip and knee endoprostheses. Pathologe. 2004, 25 (5): 375-84. 10.1007/s00292-004-0710-9.CrossRefPubMed Morawietz L, Gehrke T, Classen RA, Barden B, Otto M, Hansen T, Aigner T, Stiehl P, Neidel J, Schroder JH, Frommelt L, Schubert T, Meyer-Scholten C, Konig A, Strobel P, Rader ChP, Kirschner S, Lintner F, Ruther W, Skwara A, Bos I, Kriegsmann J, Krenn V: Proposal for the classification of the periprosthetic membrane from loosened hip and knee endoprostheses. Pathologe. 2004, 25 (5): 375-84. 10.1007/s00292-004-0710-9.CrossRefPubMed
15.
go back to reference Chacko TK, Zhuang H, Stevenson K: The importance of the location of fluorodeoxyglucose uptake in periprosthetic infection in painful hip prosthesis. Nuc Med Commun. 2002, 23: 851-855. 10.1097/00006231-200209000-00008.CrossRef Chacko TK, Zhuang H, Stevenson K: The importance of the location of fluorodeoxyglucose uptake in periprosthetic infection in painful hip prosthesis. Nuc Med Commun. 2002, 23: 851-855. 10.1097/00006231-200209000-00008.CrossRef
Metadata
Title
The implications of 18F-FDG PET for the diagnosis of endoprosthetic loosening and infection in hip and knee arthroplasty: Results from a prospective, blinded study
Authors
K-St Delank
M Schmidt
JW-P Michael
M Dietlein
H Schicha
P Eysel
Publication date
01-12-2006
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2006
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/1471-2474-7-20

Other articles of this Issue 1/2006

BMC Musculoskeletal Disorders 1/2006 Go to the issue