Skip to main content
Top
Published in: Radiation Oncology 1/2014

Open Access 01-12-2014 | Research

The frequency of re-planning and its variability dependent on the modification of the re-planning criteria and IGRT correction strategy in head and neck IMRT

Authors: Markus Stoll, Kristina Giske, Jürgen Debus, Rolf Bendl, Eva Maria Stoiber

Published in: Radiation Oncology | Issue 1/2014

Login to get access

Abstract

Background

To analyse the frequency of re-planning and its variability dependent on the IGRT correction strategy and on the modification of the dosimetric criteria for re-planning for the spinal cord in head and neck IG-IMRT.

Methods

Daily kV-control-CTs of six head and neck patients (=175 CTs) were analysed. All volumes of interest were re-contoured using deformable image registration. Three IGRT correction strategies were simulated and the resulting dose distributions were computed for all fractions. Different sets of criteria with varying dose thresholds for re-planning were investigated. All sets of criteria ensure equivalent target coverage of both CTVs, but vary in the tolerance threshold of the spinal cord.

Results

The variations of the D95 and D2 in respect to the planned values ranged from -7% to +3% for both CTVs, and -2% to +6% for the spinal cord. Despite different correction vectors of the three IGRT strategies, the dosimetric differences were small. The number of fractions not requiring re-planning varied between 0% and 11% dependent on the applied IGRT correction strategy. In contrast, this number ranged between 32% and 70% dependent on the dosimetric thresholds, even though these thresholds were only gently modified.

Conclusions

The more precise the planned dose needs to be maintained over the treatment course, the more frequently re-planning is required. The influence of different IGRT correction strategies, even though geometrically notable, was found to be of only limited relevance for the re-planning frequency. In contrast, the definition and modification of thresholds for re-planning have a major impact on the re-planning frequency.
Appendix
Available only for authorised users
Literature
1.
go back to reference Zhang L, Garden AS, Lo J, Ang KK, Morrison WH, Rosenthal DI, Chambers MS, Zhu XR, Mohan R, Dong L: Multiple regions-of-interest analysis of setup uncertainties for head-and-neck cancer radiotherapy. Int J Radiat Oncol Biol Phys 2006,64(5):1559-1569.CrossRefPubMed Zhang L, Garden AS, Lo J, Ang KK, Morrison WH, Rosenthal DI, Chambers MS, Zhu XR, Mohan R, Dong L: Multiple regions-of-interest analysis of setup uncertainties for head-and-neck cancer radiotherapy. Int J Radiat Oncol Biol Phys 2006,64(5):1559-1569.CrossRefPubMed
2.
go back to reference Polat B, Wilbert J, Baier K, Flentje M, Guckenberger M: Nonrigid patient setup errors in the head-and-neck region. Strahlenther Onkol 2007,183(9):506-511.CrossRefPubMed Polat B, Wilbert J, Baier K, Flentje M, Guckenberger M: Nonrigid patient setup errors in the head-and-neck region. Strahlenther Onkol 2007,183(9):506-511.CrossRefPubMed
3.
go back to reference Giske K, Stoiber EM, Schwarz M, Stoll A, Muenter MW, Timke C, Roeder F, Debus J, Huber PE, Thieke C, Bendl R: Local setup errors in image-guided radiotherapy for head and neck cancer patients immobilized with a custom-made device. Int J Radiat Oncol Biol Phys 2011,80(2):582-589.CrossRefPubMed Giske K, Stoiber EM, Schwarz M, Stoll A, Muenter MW, Timke C, Roeder F, Debus J, Huber PE, Thieke C, Bendl R: Local setup errors in image-guided radiotherapy for head and neck cancer patients immobilized with a custom-made device. Int J Radiat Oncol Biol Phys 2011,80(2):582-589.CrossRefPubMed
4.
go back to reference Craig T, Battista J, Van Dyk J: Limitations of a convolution method for modeling geometric uncertainties in radiation therapy I. The effect of shift invariance. Med Phys 2003,30(8):2001-2011.CrossRefPubMed Craig T, Battista J, Van Dyk J: Limitations of a convolution method for modeling geometric uncertainties in radiation therapy I. The effect of shift invariance. Med Phys 2003,30(8):2001-2011.CrossRefPubMed
5.
go back to reference Elstrom UV, Wysocka BA, Muren LP, Petersen JB, Grau C: Daily kV cone-beam CT and deformable image registration as a method for studying dosimetric consequences of anatomic changes in adaptive IMRT of head and neck cancer. Acta Oncol 2010,49(7):1101-1108.CrossRefPubMed Elstrom UV, Wysocka BA, Muren LP, Petersen JB, Grau C: Daily kV cone-beam CT and deformable image registration as a method for studying dosimetric consequences of anatomic changes in adaptive IMRT of head and neck cancer. Acta Oncol 2010,49(7):1101-1108.CrossRefPubMed
6.
go back to reference Ahunbay EE, Peng C, Godley A, Schultz C, Li XA: An on-line replanning method for head and neck adaptive radiotherapy. Med Phys 2009,36(10):4776-4790.CrossRefPubMed Ahunbay EE, Peng C, Godley A, Schultz C, Li XA: An on-line replanning method for head and neck adaptive radiotherapy. Med Phys 2009,36(10):4776-4790.CrossRefPubMed
7.
go back to reference Chen AM, Daly ME, Cui J, Mathai M, Benedict S, Purdy JA: Clinical outcomes among head and neck cancer patients treated with intensity-modulated radiotherapy with and without adaptive re-planning. Head Neck 2013. in press Chen AM, Daly ME, Cui J, Mathai M, Benedict S, Purdy JA: Clinical outcomes among head and neck cancer patients treated with intensity-modulated radiotherapy with and without adaptive re-planning. Head Neck 2013. in press
8.
go back to reference Yang H, Hu W, Wang W, Chen P, Ding W, Luo W: Preplanning during intensity modulated radiation therapy improved quality of life in patients with nasopharyngeal carcinoma. Int J Radiat Oncol Biol Phys 2013,85(1):e47-e54.CrossRefPubMed Yang H, Hu W, Wang W, Chen P, Ding W, Luo W: Preplanning during intensity modulated radiation therapy improved quality of life in patients with nasopharyngeal carcinoma. Int J Radiat Oncol Biol Phys 2013,85(1):e47-e54.CrossRefPubMed
9.
go back to reference Van Kranen S, van Beek S, Mencarelli A, Rasch C, van Herk M, Sonke JJ: Correction strategies to manage deformations in head-and-neck radiotherapy. Radiother Oncol 2010,94(2):199-205.CrossRefPubMed Van Kranen S, van Beek S, Mencarelli A, Rasch C, van Herk M, Sonke JJ: Correction strategies to manage deformations in head-and-neck radiotherapy. Radiother Oncol 2010,94(2):199-205.CrossRefPubMed
10.
go back to reference Paganelli C, Peroni M, Riboldi M, Sharp GC, Ciardo D, Alterio D, Orecchia R, Baroni G: Scale invariant feature transform in adaptive radiation therapy: A tool for deformable image registration assessment and re-planning indication. Phys Med Biol 2013,58(2):287-299.CrossRefPubMed Paganelli C, Peroni M, Riboldi M, Sharp GC, Ciardo D, Alterio D, Orecchia R, Baroni G: Scale invariant feature transform in adaptive radiation therapy: A tool for deformable image registration assessment and re-planning indication. Phys Med Biol 2013,58(2):287-299.CrossRefPubMed
11.
go back to reference Stoiber EM, Schwarz M, Debus J, Bendl R, Giske K: An optimised IGRT correction vector determined from a displacement vector field: A proof of principle of a decision-making aid for re-planning. Acta Oncol 2014,53(1):33-39.CrossRefPubMed Stoiber EM, Schwarz M, Debus J, Bendl R, Giske K: An optimised IGRT correction vector determined from a displacement vector field: A proof of principle of a decision-making aid for re-planning. Acta Oncol 2014,53(1):33-39.CrossRefPubMed
12.
go back to reference Stoiber EM, Schwarz M, Huber PE, Debus J, Bendl R, Giske K: Comparison of two IGRT correction strategies in postoperative head-and-neck IMRT patients. Acta Oncol 2013,52(1):183-186.CrossRefPubMed Stoiber EM, Schwarz M, Huber PE, Debus J, Bendl R, Giske K: Comparison of two IGRT correction strategies in postoperative head-and-neck IMRT patients. Acta Oncol 2013,52(1):183-186.CrossRefPubMed
13.
go back to reference Graff P, Kirby N, Weinberg V, Chen J, Yom SS, Lambert L, Pouliot J: The residual setup errors of different IGRT alignment procedures for head and neck IMRT and the resulting dosimetric impact. Int J Radiat Oncol Biol Phys 2013,86(1):170-176.CrossRefPubMed Graff P, Kirby N, Weinberg V, Chen J, Yom SS, Lambert L, Pouliot J: The residual setup errors of different IGRT alignment procedures for head and neck IMRT and the resulting dosimetric impact. Int J Radiat Oncol Biol Phys 2013,86(1):170-176.CrossRefPubMed
14.
go back to reference Scholz C, Schultze C, Oelfke U, Bortfeld T: Development and clinical application of a fast superposition algorithm in radiation therapy. Radiother Oncol 2003,69(1):79-90.CrossRefPubMed Scholz C, Schultze C, Oelfke U, Bortfeld T: Development and clinical application of a fast superposition algorithm in radiation therapy. Radiother Oncol 2003,69(1):79-90.CrossRefPubMed
15.
go back to reference Malsch U, Thieke C, Huber PE, Bendl R: An enhanced block matching algorithm for fast elastic registration in adaptive radiotherapy. Phys Med Biol 2006,51(19):4789-4806.CrossRefPubMed Malsch U, Thieke C, Huber PE, Bendl R: An enhanced block matching algorithm for fast elastic registration in adaptive radiotherapy. Phys Med Biol 2006,51(19):4789-4806.CrossRefPubMed
16.
go back to reference Bendl R, Hoess A, Schlegel W: Virtual Simulation in Radiotherapy Planning. In Computer Vision, Virtual Reality and Robotics in Medicine. Edited by: Ayache N. Heidelberg: Springer Berlin; 1995:287-292.CrossRef Bendl R, Hoess A, Schlegel W: Virtual Simulation in Radiotherapy Planning. In Computer Vision, Virtual Reality and Robotics in Medicine. Edited by: Ayache N. Heidelberg: Springer Berlin; 1995:287-292.CrossRef
17.
go back to reference Cui Y, Galvin JM, Straube WL, Bosch WR, Purdy JA, Li XA, Xiao Y: Multi-system verification of registrations for image-guided radiotherapy in clinical trials. Int J Radiat Oncol Biol Phys 2011,81(1):305-312.PubMedCentralCrossRefPubMed Cui Y, Galvin JM, Straube WL, Bosch WR, Purdy JA, Li XA, Xiao Y: Multi-system verification of registrations for image-guided radiotherapy in clinical trials. Int J Radiat Oncol Biol Phys 2011,81(1):305-312.PubMedCentralCrossRefPubMed
18.
go back to reference Tanyi JA, Fuss MH: Volumetric image-guidance: does routine usage prompt adaptive re-planning? An institutional review. Acta Oncol 2008,47(7):1444-1453.CrossRefPubMed Tanyi JA, Fuss MH: Volumetric image-guidance: does routine usage prompt adaptive re-planning? An institutional review. Acta Oncol 2008,47(7):1444-1453.CrossRefPubMed
Metadata
Title
The frequency of re-planning and its variability dependent on the modification of the re-planning criteria and IGRT correction strategy in head and neck IMRT
Authors
Markus Stoll
Kristina Giske
Jürgen Debus
Rolf Bendl
Eva Maria Stoiber
Publication date
01-12-2014
Publisher
BioMed Central
Published in
Radiation Oncology / Issue 1/2014
Electronic ISSN: 1748-717X
DOI
https://doi.org/10.1186/1748-717X-9-175

Other articles of this Issue 1/2014

Radiation Oncology 1/2014 Go to the issue