Skip to main content
Top
Published in: International Orthopaedics 6/2015

01-06-2015 | Original Paper

The effect of multiple drilling on a sclerotic proximal tibia during total knee arthroplasty

Authors: Ji Hyun Ahn, Seung Hyo Jeong, Sung Hyun Lee

Published in: International Orthopaedics | Issue 6/2015

Login to get access

Abstract

Purpose

To assess the depth of cement penetration and the occurrence of radiolucent line (RLL) according to drill bit diameter used in multiple drilling for the sclerotic bone of the medial proximal tibia during total knee arthroplasty (TKA).

Methods

The multiple drilling procedure was performed with 2.0 mm diameter in group 1 (n = 290) and with 4.5 mm diameter in group 2 (n = 109) to enhance the cement penetration. The postoperative RLL in the cement-bone interface and the depth of cement penetration were measured under the tibial implant at three, six, 12 and 24 months after TKA. The progression of RLL was also evaluated at the latest follow-up.

Results

Cumulative occurrence rates of RLLs were significantly lower in group 2 than in group 1 at 12 and 24 months postoperatively (P = 0.005 and 0.004). The depth or width was increased in nine cases only in group 1 at the latest follow up. There was no tibial implant loosening in both groups at the latest follow-up. Mean maximal depths of cement penetration were 1.1 mm in group 1 and 4.8 mm in group 2 at three months (P < 0.001).

Conclusions

Our comparative study between the different diameters used during multiple drilling for the tibial sclerotic surface suggests that a multiple drilling technique with a larger diameter of 4.5 mm can improve the depth of cement penetration and reduce the occurrence rate of RLLs after TKAs.
Literature
1.
go back to reference Windsor RE, Scuderi GR, Moran MC, Insall JN (1989) Mechanisms of failure of the femoral and tibial components in total knee arthroplasty. Clin Orthop Relat Res 248:15–20PubMed Windsor RE, Scuderi GR, Moran MC, Insall JN (1989) Mechanisms of failure of the femoral and tibial components in total knee arthroplasty. Clin Orthop Relat Res 248:15–20PubMed
2.
go back to reference Askew MJ, Steege JW, Lewis JL, Ranieri JR, Wixson RL (1984) Effect of cement pressure and bone strength on polymethylmethacrylate fixation. J Orthop Res 4:412–420 Askew MJ, Steege JW, Lewis JL, Ranieri JR, Wixson RL (1984) Effect of cement pressure and bone strength on polymethylmethacrylate fixation. J Orthop Res 4:412–420
3.
go back to reference Krause WR, Krug W, Miller J (1982) Strength of the cement-bone interface. Clin Orthop Relat Res 163:290–299PubMed Krause WR, Krug W, Miller J (1982) Strength of the cement-bone interface. Clin Orthop Relat Res 163:290–299PubMed
4.
go back to reference Walker PS, Soudry M, Ewald FC, McVickar H (1984) Control of cement penetration in total knee arthroplasty. Clin Orthop Relat Res 185:155–164PubMed Walker PS, Soudry M, Ewald FC, McVickar H (1984) Control of cement penetration in total knee arthroplasty. Clin Orthop Relat Res 185:155–164PubMed
5.
go back to reference Smith S, Naima VS, Freeman MA (1999) The natural history of tibial radiolucent lines in a proximally cemented stemmed total knee arthroplasty. J Arthroplasty 14:3–8PubMedCrossRef Smith S, Naima VS, Freeman MA (1999) The natural history of tibial radiolucent lines in a proximally cemented stemmed total knee arthroplasty. J Arthroplasty 14:3–8PubMedCrossRef
6.
go back to reference Ecker ML, Lotke PA, Windsor RE, Cella JP (1987) Long-term results after total condylar knee arthroplasty Significance of radiolucent lines. Clin Orthop Relat Res 216:151–158PubMed Ecker ML, Lotke PA, Windsor RE, Cella JP (1987) Long-term results after total condylar knee arthroplasty Significance of radiolucent lines. Clin Orthop Relat Res 216:151–158PubMed
7.
go back to reference Ritter MA, Herbst SA, Keating EM, Faris PM (1994) Radiolucency at the bone-cement interface in total knee replacement The effects of bone-surface preparation and cement technique. J Bone Joint Surg Am 76:60–65PubMed Ritter MA, Herbst SA, Keating EM, Faris PM (1994) Radiolucency at the bone-cement interface in total knee replacement The effects of bone-surface preparation and cement technique. J Bone Joint Surg Am 76:60–65PubMed
8.
go back to reference Lutz MJ, Pincus PF, Whitehouse SL, Halliday BR (2009) The effect of cement gun and cement syringe use on the tibial cement mantle in total knee arthroplsty. J Arthroplasty 24:461–467PubMedCrossRef Lutz MJ, Pincus PF, Whitehouse SL, Halliday BR (2009) The effect of cement gun and cement syringe use on the tibial cement mantle in total knee arthroplsty. J Arthroplasty 24:461–467PubMedCrossRef
9.
go back to reference Yoga R, Sivapathasundaram N, Suresh C (2009) Use of cement gun for fixation of tibia component in total knee arthroplasty. Malaysian Orthopaedic Journal 3:72–77CrossRef Yoga R, Sivapathasundaram N, Suresh C (2009) Use of cement gun for fixation of tibia component in total knee arthroplasty. Malaysian Orthopaedic Journal 3:72–77CrossRef
10.
go back to reference Cawley DT, Kelly N, McGarry JP, Shannon FJ (2013) Cementing techniques for the tibial component in primary total knee replacement. J Bone Joint Surg 95-B:295–300CrossRef Cawley DT, Kelly N, McGarry JP, Shannon FJ (2013) Cementing techniques for the tibial component in primary total knee replacement. J Bone Joint Surg 95-B:295–300CrossRef
11.
go back to reference Chiu KY, Cheng HC, Yau WP, Tang WM, Ho HS (2010) Reading radiographs after total knee arthroplasty. Hong Kong J Orthop Surg 14:25–39 Chiu KY, Cheng HC, Yau WP, Tang WM, Ho HS (2010) Reading radiographs after total knee arthroplasty. Hong Kong J Orthop Surg 14:25–39
12.
go back to reference Kalra S, Smith TO, Berko B, Walton NP (2011) Assessment of radiolucent lines around the Oxford unicompartmental knee replacement: sensitivity and specificity for loosening. J Bone Joint Surg (Br) 93:777–781CrossRef Kalra S, Smith TO, Berko B, Walton NP (2011) Assessment of radiolucent lines around the Oxford unicompartmental knee replacement: sensitivity and specificity for loosening. J Bone Joint Surg (Br) 93:777–781CrossRef
13.
go back to reference Sadoghi P, Leithner A, Weber P, Friesenbichler J, Gruber G, Kastner N, Pohlmann K, Jansson V, Wegener B (2011) Radiolucent lines in low-contact-stress mobile-bearing total knee arthroplasty: a blinded and matched case control study. BMC Musculoskelet Disord 12:142PubMedCentralPubMedCrossRef Sadoghi P, Leithner A, Weber P, Friesenbichler J, Gruber G, Kastner N, Pohlmann K, Jansson V, Wegener B (2011) Radiolucent lines in low-contact-stress mobile-bearing total knee arthroplasty: a blinded and matched case control study. BMC Musculoskelet Disord 12:142PubMedCentralPubMedCrossRef
14.
go back to reference Vyskocil P, Gerber C, Bamert P (1999) Radiolucent lines and component stability in knee arthroplasty Standard versus fluoroscopically assisted radiographs. J Bone Joint Surg (Br) 81:24–26CrossRef Vyskocil P, Gerber C, Bamert P (1999) Radiolucent lines and component stability in knee arthroplasty Standard versus fluoroscopically assisted radiographs. J Bone Joint Surg (Br) 81:24–26CrossRef
15.
go back to reference McCaskie AW, Deehan DJ, Green TP, Lock KR, Thompson JR, Harper WM, Gregg PJ (1998) Randomised, prospective study comparing cemented and cementless total knee replacement: result of press-fit condylar total knee replacement at five years. J Bone Joint Surg (Br) 80:971–975CrossRef McCaskie AW, Deehan DJ, Green TP, Lock KR, Thompson JR, Harper WM, Gregg PJ (1998) Randomised, prospective study comparing cemented and cementless total knee replacement: result of press-fit condylar total knee replacement at five years. J Bone Joint Surg (Br) 80:971–975CrossRef
16.
go back to reference Helwig P, Konstantinidis L, Hirschmüller A, Miltenberger V, Kuminack K, Südkamp NP, Hauschild O (2013) Tibial cleaning method for cemented total knee arthroplasty: An experimental study. Indian J Ophthalmol 47:18–22 Helwig P, Konstantinidis L, Hirschmüller A, Miltenberger V, Kuminack K, Südkamp NP, Hauschild O (2013) Tibial cleaning method for cemented total knee arthroplasty: An experimental study. Indian J Ophthalmol 47:18–22
18.
go back to reference Miskovsky C, Whiteside LA, White SE (1992) The cemented unicondylar knee arthroplasty An in vitro comparison of three cement technique. Clin Orthop Relat Res 284:215–220PubMed Miskovsky C, Whiteside LA, White SE (1992) The cemented unicondylar knee arthroplasty An in vitro comparison of three cement technique. Clin Orthop Relat Res 284:215–220PubMed
19.
go back to reference Incavo SJ, Ronchetti PJ, Howe JG, Tranowski JP (1994) Tibial plateau coverage in total knee arthroplasty. Clin Orthop Relat Res 299:81–85PubMed Incavo SJ, Ronchetti PJ, Howe JG, Tranowski JP (1994) Tibial plateau coverage in total knee arthroplasty. Clin Orthop Relat Res 299:81–85PubMed
20.
go back to reference Janssen D, Mann KA, Verdonschot N (2008) Micro-mechanical modeling of the cement-bone interface: the effect of friction, morphology and material properties on the micromechanical response. J Biomech 41:3158–3163PubMedCentralPubMedCrossRef Janssen D, Mann KA, Verdonschot N (2008) Micro-mechanical modeling of the cement-bone interface: the effect of friction, morphology and material properties on the micromechanical response. J Biomech 41:3158–3163PubMedCentralPubMedCrossRef
21.
go back to reference Gray HA, Zavatsky AB, Gill HS (2010) The sclerotic line: why it appears under knee replacements (a study based on the Oxford knee). Clin Biomech 25:242–247CrossRef Gray HA, Zavatsky AB, Gill HS (2010) The sclerotic line: why it appears under knee replacements (a study based on the Oxford knee). Clin Biomech 25:242–247CrossRef
23.
go back to reference Bach CM, Biedermann R, Goebel G, Mayer E, Rachbauer F (2005) Reproducible assessment of radiolucent lines in total knee arthroplasty. Clin Orthop Relat Res 434:183–188PubMedCrossRef Bach CM, Biedermann R, Goebel G, Mayer E, Rachbauer F (2005) Reproducible assessment of radiolucent lines in total knee arthroplasty. Clin Orthop Relat Res 434:183–188PubMedCrossRef
24.
go back to reference Guha AR, Debnath UK, Graham NM (2008) Radiolucent lines below the tibial component of a total knee replacement (TKR)—a comparison between single- and two-stage cementation techniques. Int Orthop 32(4):453–457PubMedCentralPubMedCrossRef Guha AR, Debnath UK, Graham NM (2008) Radiolucent lines below the tibial component of a total knee replacement (TKR)—a comparison between single- and two-stage cementation techniques. Int Orthop 32(4):453–457PubMedCentralPubMedCrossRef
25.
go back to reference Cornell CN, Ranawat CS, Burstein AH (1986) A clinical and radiographic analysis of loosening of total knee arthroplasty components using a bilateral model. J Arthroplasty 1:157–163PubMedCrossRef Cornell CN, Ranawat CS, Burstein AH (1986) A clinical and radiographic analysis of loosening of total knee arthroplasty components using a bilateral model. J Arthroplasty 1:157–163PubMedCrossRef
26.
go back to reference Harvey IA, Manning MP, Sampath SA, Johnson R, Elloy MA (1995) Alignment of total knee arthroplasty: the relationship to radiolucency around the tibial component. Med Eng Phys 17:182–187PubMedCrossRef Harvey IA, Manning MP, Sampath SA, Johnson R, Elloy MA (1995) Alignment of total knee arthroplasty: the relationship to radiolucency around the tibial component. Med Eng Phys 17:182–187PubMedCrossRef
27.
go back to reference Hvid I, Nielsen S (1984) Total condylar knee arthroplasty. Prosthetic component positioning and radiolucent lines. Acta Orthop Scand 55:160–165PubMedCrossRef Hvid I, Nielsen S (1984) Total condylar knee arthroplasty. Prosthetic component positioning and radiolucent lines. Acta Orthop Scand 55:160–165PubMedCrossRef
28.
go back to reference Bloebaum RD, Rubman MH, Hofmann AA (1992) Bone ingrowth into porous-coated tibial components implanted with autograft bone chips Analysis of ten consecutively retrieved implants. J Arthroplasty 7:483–493PubMedCrossRef Bloebaum RD, Rubman MH, Hofmann AA (1992) Bone ingrowth into porous-coated tibial components implanted with autograft bone chips Analysis of ten consecutively retrieved implants. J Arthroplasty 7:483–493PubMedCrossRef
29.
go back to reference Matthew SA, Peter FS, William JH, Richard HR (2004) Knee failure mechanisms after total knee arthroplasty. Techniques in Knee Surgery 3:55–59CrossRef Matthew SA, Peter FS, William JH, Richard HR (2004) Knee failure mechanisms after total knee arthroplasty. Techniques in Knee Surgery 3:55–59CrossRef
30.
go back to reference Kolisek FR, Mont MA, Seyler TM, Marker DR, Jessup NM, Siddiqui JA, Monesmith E, Ulrich SD (2009) Total knee arthroplasty using cementless keels and cemented tibial trays: 10-year results. Int Orthop 33(1):117–121PubMedCentralPubMedCrossRef Kolisek FR, Mont MA, Seyler TM, Marker DR, Jessup NM, Siddiqui JA, Monesmith E, Ulrich SD (2009) Total knee arthroplasty using cementless keels and cemented tibial trays: 10-year results. Int Orthop 33(1):117–121PubMedCentralPubMedCrossRef
Metadata
Title
The effect of multiple drilling on a sclerotic proximal tibia during total knee arthroplasty
Authors
Ji Hyun Ahn
Seung Hyo Jeong
Sung Hyun Lee
Publication date
01-06-2015
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 6/2015
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-014-2551-3

Other articles of this Issue 6/2015

International Orthopaedics 6/2015 Go to the issue