The diagnostic accuracy of pocket-size cardiac ultrasound performed by unselected residents with minimal training

Authors: Vidar Ruddox, Thomas Muri Stokke, Thor Edvardsen, Jøran Hjelmesæth, Erlend Aune, Morten Bækkevar, Ingvild B. Norum, Jan Erik Otterstad

Published in: The International Journal of Cardiovascular Imaging | Issue 8/2013

Login to get access

Abstract

Pocket-size imaging devices may represent a tool for fast initial cardiac screening in the emergency setting. Pocket-size cardiac ultrasound (PCU) examinations performed by experienced echocardiographers yield acceptable diagnostic accuracy compared to standard echocardiogram (SE). However, the success of this method when used by unselected non-cardiologists remains unexplored. The current study studies the diagnostic accuracy of PCU when used by unselected internal medicine residents with minimal training. All residents were given a 2-hour introductory course in PCU (Vscan) and reported PCU results for up to 15 predefined cardiac landmarks. These were arbitrarily divided into 3 priority groups, such that left ventricle (LV) and pericardium were of first priority. Diagnostic accuracy [sensitivity/specificity and negative/positive predictive values (PPV/NPV)] and agreement were evaluated using a subsequent SE as reference. During a 9.2 months period a total of 303 patients were included in the study, the majority on the basis of presenting with chest pain or suspected heart failure. In the pooled LV and pericardial (1st priority) data, sensitivity/specificity/PPV/NPV were 61/92/70/89 % respectively. Similar specificities and NPVs were observed for the 11 remaining indices, as were lower sensitivities and PPVs. The best PCU sensitivity (76 %) was attained for the assessment of LV wall motion abnormalities. Overall agreement was k = 0.50. PCU examination performed by internal medicine residents with minimal training could provide a suitable means of ruling out cardiac pathology, as reflected in the high specificities and NPVs. It is not, however, a satisfactory tool for identifying patients with various cardiac disorders.
Appendix
Available only for authorised users
Literature
1.
go back to reference Sicari R, Galderisi M, Voigt JU, Habib G, Zamorano JL, Lancellotti P, Badano LP (2011) The use of pocket-size imaging devices: a position statement of the European Association of Echocardiography. Eur J Echocardiogr 12(2):85–87. doi:10.1093/ejechocard/jeq184 PubMedCrossRef Sicari R, Galderisi M, Voigt JU, Habib G, Zamorano JL, Lancellotti P, Badano LP (2011) The use of pocket-size imaging devices: a position statement of the European Association of Echocardiography. Eur J Echocardiogr 12(2):85–87. doi:10.​1093/​ejechocard/​jeq184 PubMedCrossRef
3.
go back to reference Galderisi M, Santoro A, Versiero M, Lomoriello VS, Esposito R, Raia R, Farina F, Schiattarella PL, Bonito M, Olibet M, de Simone G (2010) Improved cardiovascular diagnostic accuracy by pocket size imaging device in non-cardiologic outpatients: the NaUSiCa (Naples Ultrasound Stethoscope in Cardiology) study. Cardiovasc Ultrasound 8:51. doi:10.1186/1476-7120-8-51 PubMedCrossRef Galderisi M, Santoro A, Versiero M, Lomoriello VS, Esposito R, Raia R, Farina F, Schiattarella PL, Bonito M, Olibet M, de Simone G (2010) Improved cardiovascular diagnostic accuracy by pocket size imaging device in non-cardiologic outpatients: the NaUSiCa (Naples Ultrasound Stethoscope in Cardiology) study. Cardiovasc Ultrasound 8:51. doi:10.​1186/​1476-7120-8-51 PubMedCrossRef
5.
go back to reference Kimura BJ, Amundson SA, Willis CL, Gilpin EA, DeMaria AN (2002) Usefulness of a hand-held ultrasound device for bedside examination of left ventricular function. Am J Cardiol 90(9):1038–1039PubMedCrossRef Kimura BJ, Amundson SA, Willis CL, Gilpin EA, DeMaria AN (2002) Usefulness of a hand-held ultrasound device for bedside examination of left ventricular function. Am J Cardiol 90(9):1038–1039PubMedCrossRef
7.
go back to reference Wittich CM, Montgomery SC, Neben MA, Palmer BA, Callahan MJ, Seward JB, Pawlina W, Bruce CJ (2002) Teaching cardiovascular anatomy to medical students by using a handheld ultrasound device. JAMA 288(9):1062–1063PubMedCrossRef Wittich CM, Montgomery SC, Neben MA, Palmer BA, Callahan MJ, Seward JB, Pawlina W, Bruce CJ (2002) Teaching cardiovascular anatomy to medical students by using a handheld ultrasound device. JAMA 288(9):1062–1063PubMedCrossRef
8.
go back to reference Bossuyt PM, Reitsma JB, Bruns DE, Gatsonis CA, Glasziou PP, Irwig LM, Moher D, Rennie D, de Vet HC, Lijmer JG, Standards for Reporting of Diagnostic A (2003) The STARD statement for reporting studies of diagnostic accuracy: explanation and elaboration. Ann Intern Med 138(1):W1–W12PubMed Bossuyt PM, Reitsma JB, Bruns DE, Gatsonis CA, Glasziou PP, Irwig LM, Moher D, Rennie D, de Vet HC, Lijmer JG, Standards for Reporting of Diagnostic A (2003) The STARD statement for reporting studies of diagnostic accuracy: explanation and elaboration. Ann Intern Med 138(1):W1–W12PubMed
9.
go back to reference Popescu BA, Andrade MJ, Badano LP, Fox KF, Flachskampf FA, Lancellotti P, Varga A, Sicari R, Evangelista A, Nihoyannopoulos P, Zamorano JL, European Association of E, Document R, Derumeaux G, Kasprzak JD, Roelandt JR (2009) European Association of Echocardiography recommendations for training, competence, and quality improvement in echocardiography. Eur J Echocardiogr 10(8):893–905. doi:10.1093/ejechocard/jep151 PubMedCrossRef Popescu BA, Andrade MJ, Badano LP, Fox KF, Flachskampf FA, Lancellotti P, Varga A, Sicari R, Evangelista A, Nihoyannopoulos P, Zamorano JL, European Association of E, Document R, Derumeaux G, Kasprzak JD, Roelandt JR (2009) European Association of Echocardiography recommendations for training, competence, and quality improvement in echocardiography. Eur J Echocardiogr 10(8):893–905. doi:10.​1093/​ejechocard/​jep151 PubMedCrossRef
11.
go back to reference Prinz C, Dohrmann J, van Buuren F, Bitter T, Bogunovic N, Horstkotte D, Faber L (2012) The importance of training in echocardiography: a validation study using pocket echocardiography. Journal Cardiovasc Med 13(11):700–707. doi:10.2459/JCM.0b013e328356a55f CrossRef Prinz C, Dohrmann J, van Buuren F, Bitter T, Bogunovic N, Horstkotte D, Faber L (2012) The importance of training in echocardiography: a validation study using pocket echocardiography. Journal Cardiovasc Med 13(11):700–707. doi:10.​2459/​JCM.​0b013e328356a55f​ CrossRef
12.
go back to reference Pelliccia F, Palmiero P, Maiello M, Losi MA, On behalf of the Italian chapter of the international society of cardiovascular U (2012) Italian chapter of the international society of cardiovascular ultrasound expert consensus document on training requirements for noncardiologists using hand-carried ultrasound devices. Echocardiography 29(6):745–750. doi:10.1111/j.1540-8175.2012.01720.x PubMedCrossRef Pelliccia F, Palmiero P, Maiello M, Losi MA, On behalf of the Italian chapter of the international society of cardiovascular U (2012) Italian chapter of the international society of cardiovascular ultrasound expert consensus document on training requirements for noncardiologists using hand-carried ultrasound devices. Echocardiography 29(6):745–750. doi:10.​1111/​j.​1540-8175.​2012.​01720.​x PubMedCrossRef
13.
go back to reference Panoulas VF, Daigeler AL, Malaweera AS, Lota AS, Baskaran D, Rahman S, Nihoyannopoulos P (2012) Pocket-size hand-held cardiac ultrasound as an adjunct to clinical examination in the hands of medical students and junior doctors. Eur Heart J Cardiovasc Imaging. doi:10.1093/ehjci/jes140 Panoulas VF, Daigeler AL, Malaweera AS, Lota AS, Baskaran D, Rahman S, Nihoyannopoulos P (2012) Pocket-size hand-held cardiac ultrasound as an adjunct to clinical examination in the hands of medical students and junior doctors. Eur Heart J Cardiovasc Imaging. doi:10.​1093/​ehjci/​jes140
14.
go back to reference Lang RM, Bierig M, Devereux RB, Flachskampf FA, Foster E, Pellikka PA, Picard MH, Roman MJ, Seward J, Shanewise JS, Solomon SD, Spencer KT, Sutton MS, Stewart WJ, Chamber Quantification Writing G, American Society of Echocardiography’s G, Standards C, European Association of E (2005) Recommendations for chamber quantification: a report from the American society of echocardiography’s guidelines and standards committee and the chamber quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European society of cardiology. J Am Soc Echocardiogr 18(12):1440–1463. doi:10.1016/j.echo.2005.10.005 PubMedCrossRef Lang RM, Bierig M, Devereux RB, Flachskampf FA, Foster E, Pellikka PA, Picard MH, Roman MJ, Seward J, Shanewise JS, Solomon SD, Spencer KT, Sutton MS, Stewart WJ, Chamber Quantification Writing G, American Society of Echocardiography’s G, Standards C, European Association of E (2005) Recommendations for chamber quantification: a report from the American society of echocardiography’s guidelines and standards committee and the chamber quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European society of cardiology. J Am Soc Echocardiogr 18(12):1440–1463. doi:10.​1016/​j.​echo.​2005.​10.​005 PubMedCrossRef
15.
go back to reference Lancellotti P, Tribouilloy C, Hagendorff A, Popescu BA, Edvardsen T, Pierard LA, Badano L, Zamorano JL, Scientific Document Committee of the European Association of Cardiovascular Imaging: Thor Edvardsen OBBCEDRDMGPLDMKNRS (2013) Recommendations for the echocardiographic assessment of native valvular regurgitation: an executive summary from the European Association of cardiovascular imaging. Eur Heart J Cardiovasc Imaging 14(7):611–644. doi:10.1093/ehjci/jet105 PubMedCrossRef Lancellotti P, Tribouilloy C, Hagendorff A, Popescu BA, Edvardsen T, Pierard LA, Badano L, Zamorano JL, Scientific Document Committee of the European Association of Cardiovascular Imaging: Thor Edvardsen OBBCEDRDMGPLDMKNRS (2013) Recommendations for the echocardiographic assessment of native valvular regurgitation: an executive summary from the European Association of cardiovascular imaging. Eur Heart J Cardiovasc Imaging 14(7):611–644. doi:10.​1093/​ehjci/​jet105 PubMedCrossRef
16.
go back to reference Otterstad JE, Froeland G, St John Sutton M, Holme I (1997) Accuracy and reproducibility of biplane two-dimensional echocardiographic measurements of left ventricular dimensions and function. Eur Heart J 18(3):507–513PubMedCrossRef Otterstad JE, Froeland G, St John Sutton M, Holme I (1997) Accuracy and reproducibility of biplane two-dimensional echocardiographic measurements of left ventricular dimensions and function. Eur Heart J 18(3):507–513PubMedCrossRef
17.
go back to reference Skjaerpe T, Hegrenaes L, Hatle L (1985) Noninvasive estimation of valve area in patients with aortic stenosis by Doppler ultrasound and two-dimensional echocardiography. Circulation 72(4):810–818PubMedCrossRef Skjaerpe T, Hegrenaes L, Hatle L (1985) Noninvasive estimation of valve area in patients with aortic stenosis by Doppler ultrasound and two-dimensional echocardiography. Circulation 72(4):810–818PubMedCrossRef
18.
go back to reference Zoghbi WA, Enriquez-Sarano M, Foster E, Grayburn PA, Kraft CD, Levine RA, Nihoyannopoulos P, Otto CM, Quinones MA, Rakowski H, Stewart WJ, Waggoner A, Weissman NJ, American Society of E (2003) Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography. J Am Soc Echocardiogr 16(7):777–802. doi:10.1016/S0894-7317(03)00335-3 PubMedCrossRef Zoghbi WA, Enriquez-Sarano M, Foster E, Grayburn PA, Kraft CD, Levine RA, Nihoyannopoulos P, Otto CM, Quinones MA, Rakowski H, Stewart WJ, Waggoner A, Weissman NJ, American Society of E (2003) Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography. J Am Soc Echocardiogr 16(7):777–802. doi:10.​1016/​S0894-7317(03)00335-3 PubMedCrossRef
19.
go back to reference Lancellotti P, Moura L, Pierard LA, Agricola E, Popescu BA, Tribouilloy C, Hagendorff A, Monin JL, Badano L, Zamorano JL, European Association of E (2010) European Association of Echocardiography recommendations for the assessment of valvular regurgitation. Part 2: mitral and tricuspid regurgitation (native valve disease). Eur J Echocardiogr 11(4):307–332. doi:10.1093/ejechocard/jeq031 PubMedCrossRef Lancellotti P, Moura L, Pierard LA, Agricola E, Popescu BA, Tribouilloy C, Hagendorff A, Monin JL, Badano L, Zamorano JL, European Association of E (2010) European Association of Echocardiography recommendations for the assessment of valvular regurgitation. Part 2: mitral and tricuspid regurgitation (native valve disease). Eur J Echocardiogr 11(4):307–332. doi:10.​1093/​ejechocard/​jeq031 PubMedCrossRef
20.
go back to reference Lancellotti P, Tribouilloy C, Hagendorff A, Moura L, Popescu BA, Agricola E, Monin JL, Pierard LA, Badano L, Zamorano JL, European Association of E (2010) European Association of Echocardiography recommendations for the assessment of valvular regurgitation. Part 1: aortic and pulmonary regurgitation (native valve disease). Eur J Echocardiogr 11(3):223–244. doi:10.1093/ejechocard/jeq030 PubMedCrossRef Lancellotti P, Tribouilloy C, Hagendorff A, Moura L, Popescu BA, Agricola E, Monin JL, Pierard LA, Badano L, Zamorano JL, European Association of E (2010) European Association of Echocardiography recommendations for the assessment of valvular regurgitation. Part 1: aortic and pulmonary regurgitation (native valve disease). Eur J Echocardiogr 11(3):223–244. doi:10.​1093/​ejechocard/​jeq030 PubMedCrossRef
21.
go back to reference Messika-Zeitoun D, Bellamy M, Avierinos JF, Breen J, Eusemann C, Rossi A, Behrenbeck T, Scott C, Tajik JA, Enriquez-Sarano M (2007) Left atrial remodelling in mitral regurgitation–methodologic approach, physiological determinants, and outcome implications: a prospective quantitative Doppler-echocardiographic and electron beam-computed tomographic study. Eur Heart J 28(14):1773–1781. doi:10.1093/eurheartj/ehm199 PubMedCrossRef Messika-Zeitoun D, Bellamy M, Avierinos JF, Breen J, Eusemann C, Rossi A, Behrenbeck T, Scott C, Tajik JA, Enriquez-Sarano M (2007) Left atrial remodelling in mitral regurgitation–methodologic approach, physiological determinants, and outcome implications: a prospective quantitative Doppler-echocardiographic and electron beam-computed tomographic study. Eur Heart J 28(14):1773–1781. doi:10.​1093/​eurheartj/​ehm199 PubMedCrossRef
22.
go back to reference Otterstad JE, Aune E, Beakkevar M, Froeland G, Knutsen K (2009) Normal values for volume and contractility of the 4 heart chambers based on measurements with 3 and 2-dimensional echocardiography. Hjerteforum 22:47–57 Otterstad JE, Aune E, Beakkevar M, Froeland G, Knutsen K (2009) Normal values for volume and contractility of the 4 heart chambers based on measurements with 3 and 2-dimensional echocardiography. Hjerteforum 22:47–57
Metadata
Title
The diagnostic accuracy of pocket-size cardiac ultrasound performed by unselected residents with minimal training
Authors
Vidar Ruddox
Thomas Muri Stokke
Thor Edvardsen
Jøran Hjelmesæth
Erlend Aune
Morten Bækkevar
Ingvild B. Norum
Jan Erik Otterstad
Publication date
01-12-2013
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 8/2013
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-013-0278-7

Other articles of this Issue 8/2013

The International Journal of Cardiovascular Imaging 8/2013 Go to the issue