Skip to main content
Top
Published in: Journal of Anesthesia 1/2015

01-02-2015 | Original Article

The comparison between stroke volume variation and filling pressure as an estimate of right ventricular preload in patients undergoing renal transplantation

Authors: Daisuke Toyoda, Mitsue Fukuda, Ririko Iwasaki, Takashi Terada, Nobukazu Sato, Ryoichi Ochiai, Yoshifumi Kotake

Published in: Journal of Anesthesia | Issue 1/2015

Login to get access

Abstract

Purpose

The purpose of this prospective, observational study was to respiratory variation of stroke volume (stroke volume variation, SVV) against central venous pressure (CVP) and pulmonary artery diastolic pressure (PADP) as an estimate of right and left ventricular preload.

Methods

With IRB approval and informed consent, 31 patients undergoing living related renal transplantation were analyzed. Under general anesthesia with positive pressure ventilation, stroke volume index and SVV were continuously monitored with FloTrac/Vigileo monitor. Right ventricular end-diastolic volume index (RVEDVI) as well as CVP and PADP were continuously monitored with volumetric pulmonary artery catheter. Data of every 30 min interval were used for analysis. The relationship between RVEDVI and CVP, PADP, SVV was analyzed with non-linear regression and the goodness-of-fit was assessed with coefficient of determination (R 2) of each regression curve. The ability of CVP, PADP and SVV to correctly differentiate RVEDVI <100, <120 or >138 ml/m2, which were used to guide fluid administration, was also assessed with ROC analysis.

Results

Three hundred forty-eight data sets were obtained and analyzed. The goodness of fit between RVEDVI and SVV (R 2 = 0.48) was better than that between RVEDVI and CVP or PADP (R 2 = 0.19 and 0.33, respectively). The area under the ROC curve of SVV was significantly high compared to CVP or PADP.

Conclusions

This study confirmed the theoretical framework of right ventricular preload and ventricular filling pressure and respiratory variation of stroke volume. The result also suggests that SVV can correctly predict preload status compared to pressure-based indices.
Literature
1.
go back to reference Michard F, Teboul JL. Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest. 2002;121:2000–8.CrossRefPubMed Michard F, Teboul JL. Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest. 2002;121:2000–8.CrossRefPubMed
2.
go back to reference Osman D, Ridel C, Ray P, Monnet X, Anguel N, Richard C, Teboul JL. Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge. Crit Care Med. 2007;35:64–8.CrossRefPubMed Osman D, Ridel C, Ray P, Monnet X, Anguel N, Richard C, Teboul JL. Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge. Crit Care Med. 2007;35:64–8.CrossRefPubMed
3.
go back to reference Biais M, Nouette-Gaulain K, Cottenceau V, Revel P, Sztark F. Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation. Br J Anaesth. 2008;101:761–8.CrossRefPubMed Biais M, Nouette-Gaulain K, Cottenceau V, Revel P, Sztark F. Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation. Br J Anaesth. 2008;101:761–8.CrossRefPubMed
4.
go back to reference Cannesson M, Musard H, Desebbe O, Boucau C, Simon R, Henaine R, Lehot JJ. The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients. Anesth Analg. 2009;108:513–7.CrossRefPubMed Cannesson M, Musard H, Desebbe O, Boucau C, Simon R, Henaine R, Lehot JJ. The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients. Anesth Analg. 2009;108:513–7.CrossRefPubMed
5.
go back to reference Forget P, Lois F, de Kock M. Goal-directed fluid management based on the pulse oximeter-derived pleth variability index reduces lactate levels and improves fluid management. Anesth Analg. 2010;111:910–4.PubMed Forget P, Lois F, de Kock M. Goal-directed fluid management based on the pulse oximeter-derived pleth variability index reduces lactate levels and improves fluid management. Anesth Analg. 2010;111:910–4.PubMed
6.
go back to reference Biancofiore G, Critchley LA, Lee A, Yang XX, Bindi LM, Esposito M, Bisa M, Meacci L, Mozzo R, Filipponi F. Evaluation of a new software version of the FloTrac/Vigileo (version 3.02) and a comparison with previous data in cirrhotic patients undergoing liver transplant surgery. Anesth Analg. 2011;113:515–22.PubMed Biancofiore G, Critchley LA, Lee A, Yang XX, Bindi LM, Esposito M, Bisa M, Meacci L, Mozzo R, Filipponi F. Evaluation of a new software version of the FloTrac/Vigileo (version 3.02) and a comparison with previous data in cirrhotic patients undergoing liver transplant surgery. Anesth Analg. 2011;113:515–22.PubMed
7.
go back to reference Tsai YF, Su BC, Lin CC, Liu FC, Lee WC, Yu HP. Cardiac output derived from arterial pressure waveform analysis: validation of the third-generation software in patients undergoing orthotopic liver transplantation. Transpl Proc. 2012;44:433–7.CrossRef Tsai YF, Su BC, Lin CC, Liu FC, Lee WC, Yu HP. Cardiac output derived from arterial pressure waveform analysis: validation of the third-generation software in patients undergoing orthotopic liver transplantation. Transpl Proc. 2012;44:433–7.CrossRef
8.
go back to reference Hein M, Roehl AB, Baumert JH, Rossaint R, Steendijk P. Continuous right ventricular volumetry by fast-response thermodilution during right ventricular ischemia: head-to-head comparison with conductance catheter measurements. Crit Care Med. 2009;37:2962–7.CrossRefPubMed Hein M, Roehl AB, Baumert JH, Rossaint R, Steendijk P. Continuous right ventricular volumetry by fast-response thermodilution during right ventricular ischemia: head-to-head comparison with conductance catheter measurements. Crit Care Med. 2009;37:2962–7.CrossRefPubMed
9.
go back to reference Sprung J, Kapural L, Bourke DL, O’Hara JF Jr. Anesthesia for kidney transplant surgery. Anesthesiol Clin North Am. 2000;18:919–51.CrossRef Sprung J, Kapural L, Bourke DL, O’Hara JF Jr. Anesthesia for kidney transplant surgery. Anesthesiol Clin North Am. 2000;18:919–51.CrossRef
10.
go back to reference He Z, Qiao H, Zhou W, Wang Y, Xu Z, Che X, Zhang J, Liang W. Assessment of cardiac preload status by pulse pressure variation in patients after anesthesia induction: comparison with central venous pressure and initial distribution volume of glucose. J Anesth. 2011;25:812–7.CrossRefPubMed He Z, Qiao H, Zhou W, Wang Y, Xu Z, Che X, Zhang J, Liang W. Assessment of cardiac preload status by pulse pressure variation in patients after anesthesia induction: comparison with central venous pressure and initial distribution volume of glucose. J Anesth. 2011;25:812–7.CrossRefPubMed
11.
go back to reference Kincaid EH, Meredith JW, Chang MC. Determining optimal cardiac preload during resuscitation using measurements of ventricular compliance. J Trauma. 2001;50:665–9.CrossRefPubMed Kincaid EH, Meredith JW, Chang MC. Determining optimal cardiac preload during resuscitation using measurements of ventricular compliance. J Trauma. 2001;50:665–9.CrossRefPubMed
12.
go back to reference Diebel LN, Wilson RF, Tagett MG, Kline RA. End-diastolic volume. A better indicator of preload in the critically ill. Arch Surg. 1992;127:817–21.CrossRefPubMed Diebel LN, Wilson RF, Tagett MG, Kline RA. End-diastolic volume. A better indicator of preload in the critically ill. Arch Surg. 1992;127:817–21.CrossRefPubMed
13.
go back to reference Chang MC, Meredith JW. Cardiac preload, splanchnic perfusion, and their relationship during resuscitation in trauma patients. J Trauma. 1997;42:577–82.CrossRefPubMed Chang MC, Meredith JW. Cardiac preload, splanchnic perfusion, and their relationship during resuscitation in trauma patients. J Trauma. 1997;42:577–82.CrossRefPubMed
14.
go back to reference Miller PR, Meredith JW, Chang MC. Randomized, prospective comparison of increased preload versus inotropes in the resuscitation of trauma patients: effects on cardiopulmonary function and visceral perfusion. J Trauma. 1998;44:107–13.CrossRefPubMed Miller PR, Meredith JW, Chang MC. Randomized, prospective comparison of increased preload versus inotropes in the resuscitation of trauma patients: effects on cardiopulmonary function and visceral perfusion. J Trauma. 1998;44:107–13.CrossRefPubMed
15.
go back to reference Akobeng AK. Understanding diagnostic tests 3: receiver operating characteristic curves. Acta Paediatr. 2007;96:644–7.CrossRefPubMed Akobeng AK. Understanding diagnostic tests 3: receiver operating characteristic curves. Acta Paediatr. 2007;96:644–7.CrossRefPubMed
16.
go back to reference Reuter DA, Goetz AE. Differentiating “volumetric preload monitoring” and assessing “fluid responsiveness”. Anesth Analg. 2006;102:651–2.CrossRefPubMed Reuter DA, Goetz AE. Differentiating “volumetric preload monitoring” and assessing “fluid responsiveness”. Anesth Analg. 2006;102:651–2.CrossRefPubMed
17.
go back to reference Kumar A, Anel R, Bunnell E, Habet K, Zanotti S, Marshall S, Neumann A, Ali A, Cheang M, Kavinsky C, Parrillo JE. Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects. Crit Care Med. 2004;32:691–9.CrossRefPubMed Kumar A, Anel R, Bunnell E, Habet K, Zanotti S, Marshall S, Neumann A, Ali A, Cheang M, Kavinsky C, Parrillo JE. Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects. Crit Care Med. 2004;32:691–9.CrossRefPubMed
18.
go back to reference Marik PE, Baram M, Vahid B. Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest. 2008;134:172–8.CrossRefPubMed Marik PE, Baram M, Vahid B. Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest. 2008;134:172–8.CrossRefPubMed
19.
go back to reference Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009;37:2642–7.CrossRefPubMed Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009;37:2642–7.CrossRefPubMed
20.
go back to reference Zhang Z, Lu B, Sheng X, Jin N. Accuracy of stroke volume variation in predicting fluid responsiveness: a systematic review and meta-analysis. J Anesth. 2011;25:904–16.CrossRefPubMed Zhang Z, Lu B, Sheng X, Jin N. Accuracy of stroke volume variation in predicting fluid responsiveness: a systematic review and meta-analysis. J Anesth. 2011;25:904–16.CrossRefPubMed
21.
go back to reference Michard F. Stroke volume variation: from applied physiology to improved outcomes. Crit Care Med. 2011;39:402–3.CrossRefPubMed Michard F. Stroke volume variation: from applied physiology to improved outcomes. Crit Care Med. 2011;39:402–3.CrossRefPubMed
22.
go back to reference Biais M, Ouattara A, Janvier G, Sztark F. Case scenario: respiratory variations in arterial pressure for guiding fluid management in mechanically ventilated patients. Anesthesiology. 2012;116:1354–61.CrossRefPubMed Biais M, Ouattara A, Janvier G, Sztark F. Case scenario: respiratory variations in arterial pressure for guiding fluid management in mechanically ventilated patients. Anesthesiology. 2012;116:1354–61.CrossRefPubMed
23.
go back to reference Spahn DR, Chassot PG. CON: fluid restriction for cardiac patients during major noncardiac surgery should be replaced by goal-directed intravascular fluid administration. Anesth Analg. 2006;102:344–6.CrossRefPubMed Spahn DR, Chassot PG. CON: fluid restriction for cardiac patients during major noncardiac surgery should be replaced by goal-directed intravascular fluid administration. Anesth Analg. 2006;102:344–6.CrossRefPubMed
24.
go back to reference Su BC, Tsai YF, Cheng CW, Yu HP, Yang MW, Lee WC, Lin CC. Stroke volume variation derived by arterial pulse contour analysis is a good indicator for preload estimation during liver transplantation. Transpl Proc. 2012;44:429–32.CrossRef Su BC, Tsai YF, Cheng CW, Yu HP, Yang MW, Lee WC, Lin CC. Stroke volume variation derived by arterial pulse contour analysis is a good indicator for preload estimation during liver transplantation. Transpl Proc. 2012;44:429–32.CrossRef
25.
go back to reference Spohr F, Hettrich P, Bauer H, Haas U, Martin E, Bottiger BW. Comparison of two methods for enhanced continuous circulatory monitoring in patients with septic shock. Intensive Care Med. 2007;33:1805–10.CrossRefPubMed Spohr F, Hettrich P, Bauer H, Haas U, Martin E, Bottiger BW. Comparison of two methods for enhanced continuous circulatory monitoring in patients with septic shock. Intensive Care Med. 2007;33:1805–10.CrossRefPubMed
26.
go back to reference Michard F. Changes in arterial pressure during mechanical ventilation. Anesthesiology. 2005;103:419–28.CrossRefPubMed Michard F. Changes in arterial pressure during mechanical ventilation. Anesthesiology. 2005;103:419–28.CrossRefPubMed
27.
go back to reference Taguchi H, Ichinose K, Tanimoto H, Sugita M, Tashiro M, Yamamoto T. Stroke volume variation obtained with Vigileo/FloTrac system during bleeding and fluid overload in dogs. J Anesth. 2011;25:563–8.CrossRefPubMed Taguchi H, Ichinose K, Tanimoto H, Sugita M, Tashiro M, Yamamoto T. Stroke volume variation obtained with Vigileo/FloTrac system during bleeding and fluid overload in dogs. J Anesth. 2011;25:563–8.CrossRefPubMed
28.
go back to reference Ytrebo LM. Stop filling patients against central venous pressure, please! Crit Care Med. 2011;39:396–7.CrossRefPubMed Ytrebo LM. Stop filling patients against central venous pressure, please! Crit Care Med. 2011;39:396–7.CrossRefPubMed
29.
go back to reference Wagner JG, Leatherman JW. Right ventricular end-diastolic volume as a predictor of the hemodynamic response to a fluid challenge. Chest. 1998;113:1048–54.CrossRefPubMed Wagner JG, Leatherman JW. Right ventricular end-diastolic volume as a predictor of the hemodynamic response to a fluid challenge. Chest. 1998;113:1048–54.CrossRefPubMed
30.
go back to reference Zink W, Noll J, Rauch H, Bauer H, Desimone R, Martin E, Bottiger BW. Continuous assessment of right ventricular ejection fraction: new pulmonary artery catheter versus transoesophageal echocardiography. Anaesthesia. 2004;59:1126–32.CrossRefPubMed Zink W, Noll J, Rauch H, Bauer H, Desimone R, Martin E, Bottiger BW. Continuous assessment of right ventricular ejection fraction: new pulmonary artery catheter versus transoesophageal echocardiography. Anaesthesia. 2004;59:1126–32.CrossRefPubMed
31.
go back to reference De Simone R, Wolf I, Mottl-Link S, Bottiger BW, Rauch H, Meinzer HP, Hagl S. Intraoperative assessment of right ventricular volume and function. Eur J Cardiothorac Surg. 2005;27:988–93.CrossRefPubMed De Simone R, Wolf I, Mottl-Link S, Bottiger BW, Rauch H, Meinzer HP, Hagl S. Intraoperative assessment of right ventricular volume and function. Eur J Cardiothorac Surg. 2005;27:988–93.CrossRefPubMed
32.
go back to reference Arinc H, Gunduz H, Tamer A, Ozhan H, Akdemir R, Saglam H, Oguzhan A, Uyan C. Use of tissue Doppler to assess right ventricle function in hemodialysis patients. Am J Nephrol. 2005;25:256–61.CrossRefPubMed Arinc H, Gunduz H, Tamer A, Ozhan H, Akdemir R, Saglam H, Oguzhan A, Uyan C. Use of tissue Doppler to assess right ventricle function in hemodialysis patients. Am J Nephrol. 2005;25:256–61.CrossRefPubMed
33.
go back to reference Paneni F, Gregori M, Ciavarella GM, Sciarretta S, De Biase L, Marino L, Tocci G, Principe F, Domenici A, Luciani R, Punzo G, Mene P, Volpe M. Right ventricular dysfunction in patients with end-stage renal disease. Am J Nephrol. 2010;32:432–8.CrossRefPubMed Paneni F, Gregori M, Ciavarella GM, Sciarretta S, De Biase L, Marino L, Tocci G, Principe F, Domenici A, Luciani R, Punzo G, Mene P, Volpe M. Right ventricular dysfunction in patients with end-stage renal disease. Am J Nephrol. 2010;32:432–8.CrossRefPubMed
Metadata
Title
The comparison between stroke volume variation and filling pressure as an estimate of right ventricular preload in patients undergoing renal transplantation
Authors
Daisuke Toyoda
Mitsue Fukuda
Ririko Iwasaki
Takashi Terada
Nobukazu Sato
Ryoichi Ochiai
Yoshifumi Kotake
Publication date
01-02-2015
Publisher
Springer Japan
Published in
Journal of Anesthesia / Issue 1/2015
Print ISSN: 0913-8668
Electronic ISSN: 1438-8359
DOI
https://doi.org/10.1007/s00540-014-1870-2

Other articles of this Issue 1/2015

Journal of Anesthesia 1/2015 Go to the issue