Abstract

Although the assessment of cardiovascular risk in individual patients takes into account a range of risk factors, the diagnosis and management of hypertension (high blood pressure) is largely determined by a single numerical value, albeit that often several readings are taken over time. Given the critical impact of a decision to embark on lifelong drug therapy, the importance of ensuring that a blood pressure (BP) record is both accurate and representative is clear. However, there is good evidence that the variability of BP is such that even if measurement is of the highest quality, it can be difficult to say with confidence whether a patient is above or below a treatment threshold. This commentary argues that current BP measurement is inadequate to make the clinical decisions that are necessary and that multiple readings are required to deliver an acceptable degree of accuracy for safe decision-making. This is impractical in a doctor's surgery, and the only realistic long-term strategy is to involve the patient in measuring his or her own BP in their own environment. Evidence is presented that such a strategy is better able to predict risk, is cost-effective for diagnosing hypertension, can improve BP control and is thus better able to protect individuals in the future.
In this commentary, I explain why doctors and other healthcare professionals should increase their familiarity with the technology, be aware of its strengths and limitations and work with patients as they become more empowered in the management of their chronic condition, hypertension.
Appendix
Available only for authorised users
Literature
1.
go back to reference Lawes CM, Vander Hoorn S, Law MR, Elliot P, MacMahon S, Rodgers A: Blood pressure and the global burden of disease 2000, part II: estimates of attributable burden. J Hypertens. 2006, 24: 423-430. 10.1097/01.hjh.0000209973.67746.f0.CrossRefPubMed Lawes CM, Vander Hoorn S, Law MR, Elliot P, MacMahon S, Rodgers A: Blood pressure and the global burden of disease 2000, part II: estimates of attributable burden. J Hypertens. 2006, 24: 423-430. 10.1097/01.hjh.0000209973.67746.f0.CrossRefPubMed
2.
go back to reference Benediktsson R, Padfield PL: Maximizing the benefit of treatment in mild hypertension: three simple steps to improve diagnostic accuracy. QJM. 2004, 97 (1): 15-20. 10.1093/qjmed/hch005.CrossRefPubMed Benediktsson R, Padfield PL: Maximizing the benefit of treatment in mild hypertension: three simple steps to improve diagnostic accuracy. QJM. 2004, 97 (1): 15-20. 10.1093/qjmed/hch005.CrossRefPubMed
3.
go back to reference Rothwell P, Howard SC, Dolan E, O'Brien E, Dobson JE, Dahlof B, Sever PS, Poulter NR: Prognostic significance of visit to visit variability, maximum systolic blood pressure and episodic hypertension. Lancet. 2010, 375: 895-905. 10.1016/S0140-6736(10)60308-X.CrossRefPubMed Rothwell P, Howard SC, Dolan E, O'Brien E, Dobson JE, Dahlof B, Sever PS, Poulter NR: Prognostic significance of visit to visit variability, maximum systolic blood pressure and episodic hypertension. Lancet. 2010, 375: 895-905. 10.1016/S0140-6736(10)60308-X.CrossRefPubMed
4.
go back to reference Warren RE, Marshall T, Padfield PL, Chrubasik S: Variability of office, 24-hour ambulatory and self-monitored blood pressure measurements. Brit J Gen Pract. 2010, 60: 675-680. 10.3399/bjgp10X515403.CrossRef Warren RE, Marshall T, Padfield PL, Chrubasik S: Variability of office, 24-hour ambulatory and self-monitored blood pressure measurements. Brit J Gen Pract. 2010, 60: 675-680. 10.3399/bjgp10X515403.CrossRef
5.
go back to reference Little P, Barnett J, Barnsley L, Marjoram J, Fitzgerald-Barron A, Mant D: Comparison of agreement between different measures of blood pressure in primary care and daytime ambulatory blood pressure. BMJ. 2002, 325: 254-259. 10.1136/bmj.325.7358.254.CrossRefPubMedPubMedCentral Little P, Barnett J, Barnsley L, Marjoram J, Fitzgerald-Barron A, Mant D: Comparison of agreement between different measures of blood pressure in primary care and daytime ambulatory blood pressure. BMJ. 2002, 325: 254-259. 10.1136/bmj.325.7358.254.CrossRefPubMedPubMedCentral
8.
go back to reference McGowan N, Padfield PL: Self blood pressure monitoring: a worthy substitute for ambulatory blood pressure?. J Hum Hypertens. 2010 McGowan N, Padfield PL: Self blood pressure monitoring: a worthy substitute for ambulatory blood pressure?. J Hum Hypertens. 2010
9.
go back to reference Pickering TG, Miller NH, Ogedegbe G, Krakoff LR, Artinian NT, Goff D: Call to action on use and reimbursement for home blood pressure monitoring: a joint scientific statement from the American Heart Association, American Society of Hypertension, and Preventive Cardiovascular Nurses Association. Hypertension. 2008, 52: 10-29. 10.1161/HYPERTENSIONAHA.107.189010.CrossRefPubMedPubMedCentral Pickering TG, Miller NH, Ogedegbe G, Krakoff LR, Artinian NT, Goff D: Call to action on use and reimbursement for home blood pressure monitoring: a joint scientific statement from the American Heart Association, American Society of Hypertension, and Preventive Cardiovascular Nurses Association. Hypertension. 2008, 52: 10-29. 10.1161/HYPERTENSIONAHA.107.189010.CrossRefPubMedPubMedCentral
10.
go back to reference McManus RJ, Ryan A, Greenfield S, Pattison HM, Clifford S, Marriott J, Wilson S: Self measurement of blood pressure: a community survey. J Hum Hypertens. 2007, 21: 741-743. 10.1038/sj.jhh.1002217.CrossRefPubMed McManus RJ, Ryan A, Greenfield S, Pattison HM, Clifford S, Marriott J, Wilson S: Self measurement of blood pressure: a community survey. J Hum Hypertens. 2007, 21: 741-743. 10.1038/sj.jhh.1002217.CrossRefPubMed
11.
go back to reference McManus RJ, Glasziou P, Hayen A, Mant J, Padfield P, Potter J Bray EP, Mant D: Blood pressure self monitoring: questions and answers from a national conference. BMJ. 2008, 337: 2732-10.1136/bmj.a2732.CrossRef McManus RJ, Glasziou P, Hayen A, Mant J, Padfield P, Potter J Bray EP, Mant D: Blood pressure self monitoring: questions and answers from a national conference. BMJ. 2008, 337: 2732-10.1136/bmj.a2732.CrossRef
12.
go back to reference Cappuccio FP, Kerry SM, Forbes L, Donald A: Blood pressure control by home monitoring: meta-analysis of randomised trials. BMJ. 2004, 329: 145-151. 10.1136/bmj.38121.684410.AE.CrossRefPubMedPubMedCentral Cappuccio FP, Kerry SM, Forbes L, Donald A: Blood pressure control by home monitoring: meta-analysis of randomised trials. BMJ. 2004, 329: 145-151. 10.1136/bmj.38121.684410.AE.CrossRefPubMedPubMedCentral
13.
go back to reference Rogers MA, Small D, Buchan DA, Butch CA, Stewart CM, Krenzer BE, Husovsky HL: Home monitoring service improves mean arterial pressure in patients with essential hypertension: a randomized, controlled trial. Ann Intern Med. 2001, 134: 1024-1032.CrossRefPubMed Rogers MA, Small D, Buchan DA, Butch CA, Stewart CM, Krenzer BE, Husovsky HL: Home monitoring service improves mean arterial pressure in patients with essential hypertension: a randomized, controlled trial. Ann Intern Med. 2001, 134: 1024-1032.CrossRefPubMed
14.
go back to reference Green BB, Cook AJ, Ralston JD, Fishman PA, Catz SL, Carlson J, Carrell D, Tyll L, Larson EB, Thompson RS: Effectiveness of home blood pressure monitoring, Web communication, and pharmacist care on hypertension control: a randomized controlled trial. JAMA. 2008, 299: 2857-2867. 10.1001/jama.299.24.2857.CrossRefPubMedPubMedCentral Green BB, Cook AJ, Ralston JD, Fishman PA, Catz SL, Carlson J, Carrell D, Tyll L, Larson EB, Thompson RS: Effectiveness of home blood pressure monitoring, Web communication, and pharmacist care on hypertension control: a randomized controlled trial. JAMA. 2008, 299: 2857-2867. 10.1001/jama.299.24.2857.CrossRefPubMedPubMedCentral
15.
go back to reference McManus RJ, Mant J, Bray EP, Holder R, Jones MI, Greenfield S, Kaambwa B, Banting M, Bryan S, Little P, Williams B, Hobbs R: Telemonitoring and self management in the control of hypertension (TASMINH2): a randomised controlled trial. Lancet. 2010, 376: 163-172. 10.1016/S0140-6736(10)60964-6.CrossRefPubMed McManus RJ, Mant J, Bray EP, Holder R, Jones MI, Greenfield S, Kaambwa B, Banting M, Bryan S, Little P, Williams B, Hobbs R: Telemonitoring and self management in the control of hypertension (TASMINH2): a randomised controlled trial. Lancet. 2010, 376: 163-172. 10.1016/S0140-6736(10)60964-6.CrossRefPubMed
16.
go back to reference Padfield PL: Self-monitored blood pressure: a role in clinical practice?. Blood Press Monit. 2002, 7 (1): 41-44. 10.1097/00126097-200202000-00008.CrossRefPubMed Padfield PL: Self-monitored blood pressure: a role in clinical practice?. Blood Press Monit. 2002, 7 (1): 41-44. 10.1097/00126097-200202000-00008.CrossRefPubMed
17.
go back to reference Parati G, Stergiou G, Asmar R, Bilo G, de Leeuw P, Imai Y, Kario K, Lurbe E, Manolis A, Mengden T, O'Brien E, Ohkubo T, Padfield P, Palatini P, Pickering TG, Redon J, Revera M, Ruilope LM, Shennan A, Staessen J, Tisler A, Waeber B, Zanchetti A, Mancia G: European Society of Hypertension Practice Guidelines for home blood pressure monitoring. J Hum Hypertens. 2010 Parati G, Stergiou G, Asmar R, Bilo G, de Leeuw P, Imai Y, Kario K, Lurbe E, Manolis A, Mengden T, O'Brien E, Ohkubo T, Padfield P, Palatini P, Pickering TG, Redon J, Revera M, Ruilope LM, Shennan A, Staessen J, Tisler A, Waeber B, Zanchetti A, Mancia G: European Society of Hypertension Practice Guidelines for home blood pressure monitoring. J Hum Hypertens. 2010
Metadata
Title
The case for home monitoring in hypertension
Author
Paul L Padfield
Publication date
01-12-2010
Publisher
BioMed Central
Published in
BMC Medicine / Issue 1/2010
Electronic ISSN: 1741-7015
DOI
https://doi.org/10.1186/1741-7015-8-55

Other articles of this Issue 1/2010

BMC Medicine 1/2010 Go to the issue