Abstract

The Adaptiva custom-made stem is a hip stem anchored by fit and fill press-fit into the proximal femur and manufacture is based on computed tomography (CT) scanning. Its concept was developed for primary and revision hip arthroplasty in younger patients in our clinic. We present the advantages and the disadvantages of the system. After 66 months 98.9% of the patients are satisfied with the surgical outcome; 86% attained very good and 9% good results according to the Merle d’Aubigné score. Despite good clinical results and a high satisfaction rate, we stopped using this stem because we do not see any advantages in comparison with standard implants and feel that the price for a custom-made stem for primary hip arthroplasty is too high.
Literature
1.
go back to reference Arabmotlagh M, Hennings T, Rittmeister M (2003) Femoral periprosthetic bone remodeling to the proximal femur after implantation of custom made anatomic and standard straight stem hip prostheses. Z Orthop Ihre Grenzgeb 141(5):519–525PubMedCrossRef Arabmotlagh M, Hennings T, Rittmeister M (2003) Femoral periprosthetic bone remodeling to the proximal femur after implantation of custom made anatomic and standard straight stem hip prostheses. Z Orthop Ihre Grenzgeb 141(5):519–525PubMedCrossRef
2.
go back to reference Aldinger G, Weipert A (1991) 3D-based production of hip joints: the Aldinger system. Radiologe 31:474–480PubMed Aldinger G, Weipert A (1991) 3D-based production of hip joints: the Aldinger system. Radiologe 31:474–480PubMed
3.
go back to reference Aldinger P, Thomsen M, Mau H, Ewerbeck V, Breusch S (2003) Cementless Spotorno tapered titanium stems: excellent 10-15-year survival in 141 young patients. Acta Orthop Scand 74(3):253–258PubMedCrossRef Aldinger P, Thomsen M, Mau H, Ewerbeck V, Breusch S (2003) Cementless Spotorno tapered titanium stems: excellent 10-15-year survival in 141 young patients. Acta Orthop Scand 74(3):253–258PubMedCrossRef
4.
go back to reference Arcq M (1973) Die periartikuläre Ossifikation—eine Komplikation der Totalendoprothese des Hüftgelenkes. Arch Orthop Trauma Surg 77(2):108–131 Arcq M (1973) Die periartikuläre Ossifikation—eine Komplikation der Totalendoprothese des Hüftgelenkes. Arch Orthop Trauma Surg 77(2):108–131
5.
go back to reference Chang PB, Robie BH, Bartel DL (1999) Preclinical cost analysis of orthopaedic implants: a custom versus standard cementless femoral component for revision total hip arthroplasty. J Biomech 32(12):1309–1318PubMedCrossRef Chang PB, Robie BH, Bartel DL (1999) Preclinical cost analysis of orthopaedic implants: a custom versus standard cementless femoral component for revision total hip arthroplasty. J Biomech 32(12):1309–1318PubMedCrossRef
6.
go back to reference Collis DK (1988) Long-term results of an individual surgeon. Orthop Clin North Am 19(3):541–550PubMed Collis DK (1988) Long-term results of an individual surgeon. Orthop Clin North Am 19(3):541–550PubMed
7.
go back to reference Cuckler J (2005) Limb length and stability in total hip replacement. Orthopedics 28(9):951–953PubMed Cuckler J (2005) Limb length and stability in total hip replacement. Orthopedics 28(9):951–953PubMed
8.
go back to reference Eingartner C, Heigele T, Dieter J, Winter E, Weise K (2003) Long-term results with the BiCONTACT system—aspects to investigate and to learn from. Int Orthop 27(Suppl 1):S11–S15PubMed Eingartner C, Heigele T, Dieter J, Winter E, Weise K (2003) Long-term results with the BiCONTACT system—aspects to investigate and to learn from. Int Orthop 27(Suppl 1):S11–S15PubMed
9.
go back to reference Götze C, Steens W, Vieth V, Poremba C, Claes L, Steinbeck J (2002) Primary stability in cementless femoral stems: custom-made versus conventional femoral prosthesis. Clin Biomech 17(4):267–273CrossRef Götze C, Steens W, Vieth V, Poremba C, Claes L, Steinbeck J (2002) Primary stability in cementless femoral stems: custom-made versus conventional femoral prosthesis. Clin Biomech 17(4):267–273CrossRef
10.
go back to reference Goldstein W, Gordon A, Branson J (2005) Leg length inequality in total hip arthroplasty. Orthopedics 28(9):1037–1040 Goldstein W, Gordon A, Branson J (2005) Leg length inequality in total hip arthroplasty. Orthopedics 28(9):1037–1040
11.
go back to reference Gruen TA, McNeice GM, Amstutz HC (1979) Modes of failure of cemented stem-type femoral components. Clin Orthop 141:17–27PubMed Gruen TA, McNeice GM, Amstutz HC (1979) Modes of failure of cemented stem-type femoral components. Clin Orthop 141:17–27PubMed
12.
go back to reference Hua J, Walker PS (1994) Relative motion of hip stems under load. An in vitro study of symmetrical, asymmetrical, and custom asymmetrical designs. J Bone Joint Surg Am 76(1):95–103PubMed Hua J, Walker PS (1994) Relative motion of hip stems under load. An in vitro study of symmetrical, asymmetrical, and custom asymmetrical designs. J Bone Joint Surg Am 76(1):95–103PubMed
13.
go back to reference Hua J, Walker PS (1995) Closeness of fit of uncemented stems improves the strain distribution in the femur. J Orthop Res 13(3):339–346PubMedCrossRef Hua J, Walker PS (1995) Closeness of fit of uncemented stems improves the strain distribution in the femur. J Orthop Res 13(3):339–346PubMedCrossRef
14.
go back to reference Küsswetter W, Sell S (1993) Mittelfristige Ergebnisse mit dem zementfreien individuellen Femurersatz. Z Orthop 131:553–557PubMedCrossRef Küsswetter W, Sell S (1993) Mittelfristige Ergebnisse mit dem zementfreien individuellen Femurersatz. Z Orthop 131:553–557PubMedCrossRef
15.
go back to reference Kutschera H-P, Eyb R, Schartelmüller T, Toma C, Zweymüller K (1993) Das zementfreie Zweymüller Hüft-System. Ergebnisse einer 5-Jahres-Nachuntersuchung. Z Orthop 131:513–517PubMed Kutschera H-P, Eyb R, Schartelmüller T, Toma C, Zweymüller K (1993) Das zementfreie Zweymüller Hüft-System. Ergebnisse einer 5-Jahres-Nachuntersuchung. Z Orthop 131:513–517PubMed
16.
go back to reference Martini F (2001) Wertigkeit osteodensitometrischer Messungen unter besonderer Berücksichtigung des Verlaufs der periprothetischen Knochendichte der Individualendoprothesen Evolution-K und Adaptiva in Korrelation zur kortikalen Anlagefläche. Habilitationsschrift, Eberhard-Karls-Universität, Tübingen Martini F (2001) Wertigkeit osteodensitometrischer Messungen unter besonderer Berücksichtigung des Verlaufs der periprothetischen Knochendichte der Individualendoprothesen Evolution-K und Adaptiva in Korrelation zur kortikalen Anlagefläche. Habilitationsschrift, Eberhard-Karls-Universität, Tübingen
17.
go back to reference Martini F, Lebherz C, Mayer F, Leichtle U, Kremling E, Sell S (2000) Precision of the measurements of periprosthetic bone mineral density in hips with a custom-made femoral stem. J Bone Joint Surg Br 82(7):1065–1071PubMedCrossRef Martini F, Lebherz C, Mayer F, Leichtle U, Kremling E, Sell S (2000) Precision of the measurements of periprosthetic bone mineral density in hips with a custom-made femoral stem. J Bone Joint Surg Br 82(7):1065–1071PubMedCrossRef
18.
go back to reference Reize P, Giehl J, Schanbacher J, Bronner R (2002) Clinical and radiological results of individual hip stems of the type Adaptiva without cement. Z Orthop Ihre Grenzgeb 140(3):304–309PubMedCrossRef Reize P, Giehl J, Schanbacher J, Bronner R (2002) Clinical and radiological results of individual hip stems of the type Adaptiva without cement. Z Orthop Ihre Grenzgeb 140(3):304–309PubMedCrossRef
19.
go back to reference Rittmeister M, Eisenbeis K, Hanusek S, Yanik-Karaca Z, Starker M, Arabmotlagh M (2004) Assessment of implant position of CTX-custom-made stems with EBRA-FCA in 107 cases of total joint replacement. Z Orthop Ihre Grenzgeb 142(6):659–665PubMedCrossRef Rittmeister M, Eisenbeis K, Hanusek S, Yanik-Karaca Z, Starker M, Arabmotlagh M (2004) Assessment of implant position of CTX-custom-made stems with EBRA-FCA in 107 cases of total joint replacement. Z Orthop Ihre Grenzgeb 142(6):659–665PubMedCrossRef
20.
go back to reference Robertson DD, Walker PS, Granholm JW, Nelson PC, Weiss PJ, Fishman EK, Magid D (1987) Design of custom hip stem prostheses using three-dimensional CT modeling. J Comput Assist Tomogr 11(5):804–809PubMedCrossRef Robertson DD, Walker PS, Granholm JW, Nelson PC, Weiss PJ, Fishman EK, Magid D (1987) Design of custom hip stem prostheses using three-dimensional CT modeling. J Comput Assist Tomogr 11(5):804–809PubMedCrossRef
21.
go back to reference Sharp DJ, Porter KM (1985) The Charnley total hip arthroplasty in patients under 40. Clin Orthop 201:51–56PubMed Sharp DJ, Porter KM (1985) The Charnley total hip arthroplasty in patients under 40. Clin Orthop 201:51–56PubMed
22.
go back to reference Traulsen F, Hassenpflug J, Hahne H (2001) Long-term results with cement-free total hip prostheses (Zweymüller). Z Orthop Ihre Grenzgeb 139(3):206–211PubMedCrossRef Traulsen F, Hassenpflug J, Hahne H (2001) Long-term results with cement-free total hip prostheses (Zweymüller). Z Orthop Ihre Grenzgeb 139(3):206–211PubMedCrossRef
23.
go back to reference Wettstein M, Mouhsine E, Argenson JN, Rubin PJ, Aubaniac JM, Leyvraz PF (2005) Three-dimensional computed cementless custom femoral stems in young patients: midterm follow-up. Clin Orthop Relat Res 437:169–175PubMedCrossRef Wettstein M, Mouhsine E, Argenson JN, Rubin PJ, Aubaniac JM, Leyvraz PF (2005) Three-dimensional computed cementless custom femoral stems in young patients: midterm follow-up. Clin Orthop Relat Res 437:169–175PubMedCrossRef
24.
go back to reference Wick M, Lester D (2004) Radiological changes in second- and third-generation Zweymüller stems. J Bone Jt Surg Br 86(8):1108–1114CrossRef Wick M, Lester D (2004) Radiological changes in second- and third-generation Zweymüller stems. J Bone Jt Surg Br 86(8):1108–1114CrossRef
Metadata
Title
The Adaptiva custom-made stem—our reasons for not using it anymore
Authors
Patrik Karl Reize
Nikolaus Wülker
Publication date
01-04-2007
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 2/2007
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-006-0160-5

Other articles of this Issue 2/2007

International Orthopaedics 2/2007 Go to the issue