Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 4/2017

01-04-2017 | Orthopaedic Surgery

The accuracy of the lateral vertebral notch-referred pedicle screw insertion technique in subaxial cervical spine: a human cadaver study

Authors: Jiaquan Luo, Chunyang Wu, Zhongren Huang, Zhimin Pan, Zhiyun Li, Junlong Zhong, Yiwei Chen, Zhimin Han, Kai Cao

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 4/2017

Login to get access

Abstract

Study design

This is a cadaver specimen study to confirm new pedicle screw (PS) entry point and trajectory for subaxial cervical PS insertion.

Objective

To assess the accuracy of the lateral vertebral notch-referred PS insertion technique in subaxial cervical spine in cadaver cervical spine.

Backgrounds

Reported morphometric landmarks used to guide the surgeon in PS insertion show significant variability. In the previous study, we proposed a new technique (as called “notch-referred” technique) primarily based on coronal multiplane reconstruction images (CMRI) and cortical integrity after PS insertion in cadavers. However, the PS position in cadaveric cervical segment was not confirmed radiologically. Therefore, the difference between the pedicle trajectory and the PS trajectory using the notch-referred technique needs to be illuminated.

Methods

Twelve cadaveric cervical spines were conducted with PS insertion using the lateral vertebral notch-referred technique. The guideline for entry point and trajectory for each vertebra was established based on the morphometric data from our previous study. After 3.5-mm diameter screw insertion, each vertebra was dissected and inspected for pedicle trajectory by CT scan. The pedicle trajectory and PS trajectory were measured and compared in axial plane. The perforation rate was assessed radiologically and was graded from ideal to unacceptable: Grade 0 = screw in pedicle; Grade I = perforation of pedicle wall less than one-fourth of the screw diameter; Grade II = perforation more than one-fourth of the screw diameter but less than one-second; Grade III = perforation more than one-second outside of the screw diameter. In addition, pedicle width between the acceptable and unacceptable screws was compared.

Results

A total of 120 pedicle screws were inserted. The perforation rate of pedicle screws was 78.3% in grade 0 (excellent PS position), 10.0% in grade I (good PS position), 8.3% in grade II (fair PS position), and 3.3% in grade III (poor PS position). The overall accepted accuracy of pedicle screws was 96.7% (Grade 0 + Grade I + Grade II), and only 3.3% had critical breach. There was no statistical difference between the pedicle trajectory and PS trajectory (p > 0.05). Compared to the pedicle width (4.4 ± 0.7 mm) in acceptably inserted screw, the unacceptably screw is 3.2 ± 0.3 mm which was statistically different (p < 0.05).

Conclusion

The accuracy of the notch-referred PS insertion in cadaveric subaxial cervical spine is satisfactory.
Literature
1.
go back to reference Abumi K, Itoh H, Taneichi H, Kaneda K (1994) Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report. J Spinal Disord 7:19–28CrossRefPubMed Abumi K, Itoh H, Taneichi H, Kaneda K (1994) Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report. J Spinal Disord 7:19–28CrossRefPubMed
7.
go back to reference Abumi K, Shono Y, Ito M, Taneichi H, Kotani Y, Kaneda K (2000) Complications of pedicle screw fixation in reconstructive surgery of the cervical spine. Spine (Phila Pa 1976) 25:962–969CrossRef Abumi K, Shono Y, Ito M, Taneichi H, Kotani Y, Kaneda K (2000) Complications of pedicle screw fixation in reconstructive surgery of the cervical spine. Spine (Phila Pa 1976) 25:962–969CrossRef
8.
go back to reference Park JH, Jeon SR, Roh SW, Kim JH, Rhim SC (2014) The safety and accuracy of freehand pedicle screw placement in the subaxial cervical spine: a series of 45 consecutive patients. Spine (Phila Pa 1976) 39:280–285. doi:10.1097/BRS.0000000000000133 CrossRef Park JH, Jeon SR, Roh SW, Kim JH, Rhim SC (2014) The safety and accuracy of freehand pedicle screw placement in the subaxial cervical spine: a series of 45 consecutive patients. Spine (Phila Pa 1976) 39:280–285. doi:10.​1097/​BRS.​0000000000000133​ CrossRef
9.
10.
go back to reference Nakashima H, Yukawa Y, Imagama S, Kanemura T, Kamiya M, Yanase M, Ito K, Machino M, Yoshida G, Ishikawa Y, Matsuyama Y, Ishiguro N, Kato F (2012) Complications of cervical pedicle screw fixation for nontraumatic lesions: a multicenter study of 84 patients. J Neurosurg Spine 16:238–247. doi:10.3171/2011.11.SPINE11102 CrossRefPubMed Nakashima H, Yukawa Y, Imagama S, Kanemura T, Kamiya M, Yanase M, Ito K, Machino M, Yoshida G, Ishikawa Y, Matsuyama Y, Ishiguro N, Kato F (2012) Complications of cervical pedicle screw fixation for nontraumatic lesions: a multicenter study of 84 patients. J Neurosurg Spine 16:238–247. doi:10.​3171/​2011.​11.​SPINE11102 CrossRefPubMed
11.
go back to reference Jeanneret B, Gebhard JS, Magerl F (1994) Transpedicular screw fixation of articular mass fracture-separation: results of an anatomical study and operative technique. J Spinal Disord 7:222–229CrossRefPubMed Jeanneret B, Gebhard JS, Magerl F (1994) Transpedicular screw fixation of articular mass fracture-separation: results of an anatomical study and operative technique. J Spinal Disord 7:222–229CrossRefPubMed
12.
go back to reference Karaikovic EE, Kunakornsawat S, Daubs MD, Madsen TW, Gaines RJ (2000) Surgical anatomy of the cervical pedicles: landmarks for posterior cervical pedicle entrance localization. J Spinal Disord 13:63–72CrossRefPubMed Karaikovic EE, Kunakornsawat S, Daubs MD, Madsen TW, Gaines RJ (2000) Surgical anatomy of the cervical pedicles: landmarks for posterior cervical pedicle entrance localization. J Spinal Disord 13:63–72CrossRefPubMed
13.
go back to reference Miller RM, Ebraheim NA, Xu R, Yeasting RA (1996) Anatomic consideration of transpedicular screw placement in the cervical spine. An analysis of two approaches. Spine (Phila Pa 1976) 21:2317–2322CrossRef Miller RM, Ebraheim NA, Xu R, Yeasting RA (1996) Anatomic consideration of transpedicular screw placement in the cervical spine. An analysis of two approaches. Spine (Phila Pa 1976) 21:2317–2322CrossRef
14.
go back to reference Ludwig SC, Kramer DL, Balderston RA, Vaccaro AR, Foley KF, Albert TJ (2000) Placement of pedicle screws in the human cadaveric cervical spine: comparative accuracy of three techniques. Spine (Phila Pa 1976) 25:1655–1667CrossRef Ludwig SC, Kramer DL, Balderston RA, Vaccaro AR, Foley KF, Albert TJ (2000) Placement of pedicle screws in the human cadaveric cervical spine: comparative accuracy of three techniques. Spine (Phila Pa 1976) 25:1655–1667CrossRef
15.
go back to reference Karaikovic EE, Yingsakmongkol W, Gaines RJ (2001) Accuracy of cervical pedicle screw placement using the funnel technique. Spine (Phila Pa 1976) 26:2456–2462CrossRef Karaikovic EE, Yingsakmongkol W, Gaines RJ (2001) Accuracy of cervical pedicle screw placement using the funnel technique. Spine (Phila Pa 1976) 26:2456–2462CrossRef
16.
go back to reference Reichle E, Sellenschloh K, Morlock M, Eggers C (2002) Placement of pedicle screws using different navigation systems. A laboratory trial with 12 spinal preparations. Der Orthopade 31:368–371CrossRefPubMed Reichle E, Sellenschloh K, Morlock M, Eggers C (2002) Placement of pedicle screws using different navigation systems. A laboratory trial with 12 spinal preparations. Der Orthopade 31:368–371CrossRefPubMed
20.
22.
go back to reference Zheng X, Chaudhari R, Wu C, Mehbod AA, Transfeldt EE (2010) Subaxial cervical pedicle screw insertion with newly defined entry point and trajectory: accuracy evaluation in cadavers. Eur Spine J 19:105–112. doi:10.1007/s00586-009-1213-4 CrossRefPubMed Zheng X, Chaudhari R, Wu C, Mehbod AA, Transfeldt EE (2010) Subaxial cervical pedicle screw insertion with newly defined entry point and trajectory: accuracy evaluation in cadavers. Eur Spine J 19:105–112. doi:10.​1007/​s00586-009-1213-4 CrossRefPubMed
23.
go back to reference Wu C, Huang Z, Pan Z, Luo J, Li Z, Zhong J, Chen Y, Han Z, Cao K (2016) Coronal multiplane reconstructed CT image determining lateral vertebral notch-referred pedicle screw entry point in subaxial cervical spine. SpineWeek, Singapore Wu C, Huang Z, Pan Z, Luo J, Li Z, Zhong J, Chen Y, Han Z, Cao K (2016) Coronal multiplane reconstructed CT image determining lateral vertebral notch-referred pedicle screw entry point in subaxial cervical spine. SpineWeek, Singapore
26.
27.
go back to reference Zhang PX, Xue F, Zhang DY, Fu ZG, Han N, Kou YH, Jiang BG (2012) Positioning study of cervical vertebra pedicle axial line projective point by computed tomography image reconstruction. Chin Med J (Engl) 125:2521–2524 Zhang PX, Xue F, Zhang DY, Fu ZG, Han N, Kou YH, Jiang BG (2012) Positioning study of cervical vertebra pedicle axial line projective point by computed tomography image reconstruction. Chin Med J (Engl) 125:2521–2524
28.
go back to reference Gupta R, Kapoor K, Sharma A, Kochhar S, Garg R (2013) Morphometry of typical cervical vertebrae on dry bones and CT scan and its implications in transpedicular screw placement surgery. Surg Radiol Anat 35:181–189. doi:10.1007/s00276-012-1013-0 CrossRefPubMed Gupta R, Kapoor K, Sharma A, Kochhar S, Garg R (2013) Morphometry of typical cervical vertebrae on dry bones and CT scan and its implications in transpedicular screw placement surgery. Surg Radiol Anat 35:181–189. doi:10.​1007/​s00276-012-1013-0 CrossRefPubMed
29.
go back to reference Munusamy T, Thien A, Anthony MG, Bakthavachalam R, Dinesh SK (2015) Computed tomographic morphometric analysis of cervical pedicles in a multi-ethnic Asian population and relevance to subaxial cervical pedicle screw fixation. Eur Spine J 24:120–126. doi:10.1007/s00586-014-3526-1 CrossRefPubMed Munusamy T, Thien A, Anthony MG, Bakthavachalam R, Dinesh SK (2015) Computed tomographic morphometric analysis of cervical pedicles in a multi-ethnic Asian population and relevance to subaxial cervical pedicle screw fixation. Eur Spine J 24:120–126. doi:10.​1007/​s00586-014-3526-1 CrossRefPubMed
Metadata
Title
The accuracy of the lateral vertebral notch-referred pedicle screw insertion technique in subaxial cervical spine: a human cadaver study
Authors
Jiaquan Luo
Chunyang Wu
Zhongren Huang
Zhimin Pan
Zhiyun Li
Junlong Zhong
Yiwei Chen
Zhimin Han
Kai Cao
Publication date
01-04-2017
Publisher
Springer Berlin Heidelberg
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 4/2017
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-017-2647-5

Other articles of this Issue 4/2017

Archives of Orthopaedic and Trauma Surgery 4/2017 Go to the issue