Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 9/2009

01-09-2009 | Orthopaedic Surgery

The accuracy and precision of computer assisted surgery in the assessment of frontal plane deviations of the lower extremity: a femoral fracture model

Authors: Afshin Khalafi, Musa Citak, Daniel Kendoff, Tobias Huefner, Christian Krettek

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 9/2009

Login to get access

Abstract

Objectives

Mechanical axis deviation of the lower extremity as a result of malreduction or malunion of fractures plays an important role in the development of arthritis. Therefore it is crucial to restore the limb alignment as accurate as possible. The purpose of this study was to evaluate the accuracy and precision of navigation in assessing isolated frontal plane (varus/valgus) deviations of the lower limb in a simulated fracture model of the femur.

Materials and methods

Three fracture models with ten specimens in each were created in femoral synthetic composite bones to simulate a subtrochanteric (AO/OTA 31-A1), mid-diaphyseal (AO/OTA 32-A3), and supracondylar (AO/OTA 33-A1) femur fracture. Each specimen was mounted on a custom holding device and registered with the navigation system. Eight custom-made aluminum wedges of varying angles (5°–26°) were used to create varus/valgus angulations at the fracture site. After wedge placement, the frontal plane deformity was recorded and registered by the navigation system. The means and standard deviations for each navigated wedge angle were calculated and compared to the actual wedge angle using a one sample t test. A single factor ANOVA test was subsequently performed to see if the differences between the navigated mean angles in each fracture group were statistically significant. The level of significance was defined as P < 0.05.

Results

None of the navigated mean angles were found to be significantly different from the actual wedge angles (P = 0.05–1.00). More specifically, the differences between the navigated mean angles and the actual wedge angles ranged from 0° to 0.7°. Furthermore, the differences between the navigated mean angles in each angle group were found to be statistically insignificant (P = 0.53–0.99).

Conclusion

The high accuracy and precision of navigation systems in determining frontal plane deformities of long bones can make them an invaluable tool for the exact reduction and realignment of lower extremity fractures.
Literature
1.
go back to reference Hankemeier S, Hufner T, Wang G, Kendoff D, Zheng G, Richter M, Gosling T, Nolte L, Krettek C (2005) Navigated intraoperative analysis of lower limb alignment. Arch Orthop Trauma Surg 125:531–535PubMedCrossRef Hankemeier S, Hufner T, Wang G, Kendoff D, Zheng G, Richter M, Gosling T, Nolte L, Krettek C (2005) Navigated intraoperative analysis of lower limb alignment. Arch Orthop Trauma Surg 125:531–535PubMedCrossRef
2.
go back to reference Heller M, Taylor W, Perka C, Duda G (2003) The influence of alignment on the musculo-skeletal loading conditions at the knee. Langenbecks Arch Surg 388:291–297PubMedCrossRef Heller M, Taylor W, Perka C, Duda G (2003) The influence of alignment on the musculo-skeletal loading conditions at the knee. Langenbecks Arch Surg 388:291–297PubMedCrossRef
3.
go back to reference Gugenheim J, Brinker M (2003) Bone realignment with use of temporary external fixation for distal femoral valgus and varus deformities. J Bone Joint Surg Am 85:1229–1237PubMed Gugenheim J, Brinker M (2003) Bone realignment with use of temporary external fixation for distal femoral valgus and varus deformities. J Bone Joint Surg Am 85:1229–1237PubMed
4.
go back to reference Sharma L, Song J, Felson DT, Cahue S, Shamiyeh E, Dunlop DD (2001) The role of knee alignment in disease progression and functional decline in knee osteoarthritis. JAMA 286:188–195PubMedCrossRef Sharma L, Song J, Felson DT, Cahue S, Shamiyeh E, Dunlop DD (2001) The role of knee alignment in disease progression and functional decline in knee osteoarthritis. JAMA 286:188–195PubMedCrossRef
5.
go back to reference Paley D, Tetsworth K (1992) Mechanical axis deviations of the lower limbs. Clin Orthop Relat Res 280:48–64PubMed Paley D, Tetsworth K (1992) Mechanical axis deviations of the lower limbs. Clin Orthop Relat Res 280:48–64PubMed
6.
go back to reference Hsu RW, Himeno S, Coventry MB, Chao EY (1991) Normal axial alignment of the lower extremity and load bearing distribution at the knee. Clin Orthop 255:215–227 Hsu RW, Himeno S, Coventry MB, Chao EY (1991) Normal axial alignment of the lower extremity and load bearing distribution at the knee. Clin Orthop 255:215–227
7.
go back to reference Bathis H, Perlick L, Tingart M, Luring C, Zurakowski D, Grifka J (2004) Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br 86:682–687PubMedCrossRef Bathis H, Perlick L, Tingart M, Luring C, Zurakowski D, Grifka J (2004) Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br 86:682–687PubMedCrossRef
8.
go back to reference Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73:709–714PubMed Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73:709–714PubMed
9.
go back to reference Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59:77–79PubMed Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59:77–79PubMed
10.
go back to reference Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am 89:236–243PubMedCrossRef Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am 89:236–243PubMedCrossRef
11.
go back to reference Pandher DS, Oh KJ, Boaparai RS, Josan GS (2007) Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Relat Res 454:281–282PubMedCrossRef Pandher DS, Oh KJ, Boaparai RS, Josan GS (2007) Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Relat Res 454:281–282PubMedCrossRef
12.
go back to reference Nabeyama R, Matsuda S, Miura H, Mawatari T, Kawano T, Iwamoto Y (2004) The accuracy of image-guided knee replacement based on computer tomography. J Bone Joint Surg Br 86:366–371PubMedCrossRef Nabeyama R, Matsuda S, Miura H, Mawatari T, Kawano T, Iwamoto Y (2004) The accuracy of image-guided knee replacement based on computer tomography. J Bone Joint Surg Br 86:366–371PubMedCrossRef
13.
go back to reference Gottschling H, Roth M, Schweikard A, Burgkart R (2005) Intraoperative, fluoroscopy-based planning for complex osteotomies of the proximal femur. Int J Med Robot 1:67–73PubMed Gottschling H, Roth M, Schweikard A, Burgkart R (2005) Intraoperative, fluoroscopy-based planning for complex osteotomies of the proximal femur. Int J Med Robot 1:67–73PubMed
14.
go back to reference Jackson DW, Warkentine B (2007) Technical aspects of computer-assisted opening wedge high tibial osteotomy. J Knee Surg 20:134–141PubMed Jackson DW, Warkentine B (2007) Technical aspects of computer-assisted opening wedge high tibial osteotomy. J Knee Surg 20:134–141PubMed
15.
go back to reference Maurer F, Wassmer G (2007) High tibial osteotomy: does navigation improve results? Orthopedics 30:327 Maurer F, Wassmer G (2007) High tibial osteotomy: does navigation improve results? Orthopedics 30:327
16.
go back to reference Liebergall M, Ben-David D, Weil Y, Peyser A, Mosheiff R (2006) Computerized navigation for the internal fixation of femoral neck fractures. J Bone Joint Surg Am 88:1748–1754PubMedCrossRef Liebergall M, Ben-David D, Weil Y, Peyser A, Mosheiff R (2006) Computerized navigation for the internal fixation of femoral neck fractures. J Bone Joint Surg Am 88:1748–1754PubMedCrossRef
17.
go back to reference Mosheiff R, Weil Y, Peleg E, Liebergall M (2005) Computerised navigation for closed reduction during femoral intramedullary nailing. Injury 36:866–870PubMedCrossRef Mosheiff R, Weil Y, Peleg E, Liebergall M (2005) Computerised navigation for closed reduction during femoral intramedullary nailing. Injury 36:866–870PubMedCrossRef
18.
go back to reference Grutzner PA, Suhm N (2004) Computer aided long bone fracture treatment. Injury 35(suppl 1):S-A57–S-A64 Grutzner PA, Suhm N (2004) Computer aided long bone fracture treatment. Injury 35(suppl 1):S-A57–S-A64
19.
go back to reference Slomczykowski MA, Hofstetter R, Sati M, Krettek C, Nolte LP (2001) Novel computer-assisted fluoroscopy system for intraoperative guidance: feasibility study for distal locking of femoral nails. J Orthop Trauma 15:122–131PubMedCrossRef Slomczykowski MA, Hofstetter R, Sati M, Krettek C, Nolte LP (2001) Novel computer-assisted fluoroscopy system for intraoperative guidance: feasibility study for distal locking of femoral nails. J Orthop Trauma 15:122–131PubMedCrossRef
20.
go back to reference Chong KW, Wong MK, Rikhraj IS, Howe TS (2006) The use of computer navigation in performing minimally invasive surgery for intertrochanteric hip fractures–the experience in Singapore. Injury 37:755–762PubMedCrossRef Chong KW, Wong MK, Rikhraj IS, Howe TS (2006) The use of computer navigation in performing minimally invasive surgery for intertrochanteric hip fractures–the experience in Singapore. Injury 37:755–762PubMedCrossRef
21.
go back to reference Hofstetter R, Slomczykowski M, Krettek C, Koppen G, Sati M, Nolte LP (2000) Computer-assisted fluoroscopy-based reduction of femoral fractures and antetorsion correction. Comput Aided Surg 5:311–325PubMedCrossRef Hofstetter R, Slomczykowski M, Krettek C, Koppen G, Sati M, Nolte LP (2000) Computer-assisted fluoroscopy-based reduction of femoral fractures and antetorsion correction. Comput Aided Surg 5:311–325PubMedCrossRef
22.
go back to reference Citak M, Hufner T, Geerling J, Kfuri M Jr, Gansslen A, Look V, Kendoff D, Krettek C (2006) Navigated percutaneous pelvic sacroiliac screw fixation: experimental comparison of accuracy between fluoroscopy and Iso-C3D navigation. Comput Aided Surg 11:209–213PubMedCrossRef Citak M, Hufner T, Geerling J, Kfuri M Jr, Gansslen A, Look V, Kendoff D, Krettek C (2006) Navigated percutaneous pelvic sacroiliac screw fixation: experimental comparison of accuracy between fluoroscopy and Iso-C3D navigation. Comput Aided Surg 11:209–213PubMedCrossRef
23.
go back to reference Hufner T, Kendoff D, Citak M, Geerling J, Krettek C (2006) Precision in orthopaedic computer navigation. Orthopade 35:1043–1055PubMedCrossRef Hufner T, Kendoff D, Citak M, Geerling J, Krettek C (2006) Precision in orthopaedic computer navigation. Orthopade 35:1043–1055PubMedCrossRef
24.
go back to reference Kendoff D, Bogojevic A, Citak M, Citak M, Maier C, Maier G, Krettek C, Hufner T (2007) Experimental validation of noninvasive referencing in navigated procedures on long bones. J Orthop Res 25:201–207PubMedCrossRef Kendoff D, Bogojevic A, Citak M, Citak M, Maier C, Maier G, Krettek C, Hufner T (2007) Experimental validation of noninvasive referencing in navigated procedures on long bones. J Orthop Res 25:201–207PubMedCrossRef
25.
go back to reference Matziolis G, Krocker D, Tohtz S, Weiss U, Perka C (2006) Accuracy of determination of the hip centre in navigated total knee arthroplasty. Z Orthop Ihre Grenzgeb 144:362–366PubMedCrossRef Matziolis G, Krocker D, Tohtz S, Weiss U, Perka C (2006) Accuracy of determination of the hip centre in navigated total knee arthroplasty. Z Orthop Ihre Grenzgeb 144:362–366PubMedCrossRef
26.
go back to reference Kendoff D, Hufner T, Citak M, Geerling J, Maier C, Wesemeier F, Krettek C (2006) Implementation of a new navigated parallel drill guide for femoral neck fractures. Comput Aided Surg 11:317–321PubMedCrossRef Kendoff D, Hufner T, Citak M, Geerling J, Maier C, Wesemeier F, Krettek C (2006) Implementation of a new navigated parallel drill guide for femoral neck fractures. Comput Aided Surg 11:317–321PubMedCrossRef
27.
go back to reference Gardner MJ, Citak M, Kendoff D, Hufner T, Krettek C (2007) Decreased navigated drilling time using an external guide stabilizing device. Injury 38:755–758PubMedCrossRef Gardner MJ, Citak M, Kendoff D, Hufner T, Krettek C (2007) Decreased navigated drilling time using an external guide stabilizing device. Injury 38:755–758PubMedCrossRef
Metadata
Title
The accuracy and precision of computer assisted surgery in the assessment of frontal plane deviations of the lower extremity: a femoral fracture model
Authors
Afshin Khalafi
Musa Citak
Daniel Kendoff
Tobias Huefner
Christian Krettek
Publication date
01-09-2009
Publisher
Springer-Verlag
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 9/2009
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-009-0818-8

Other articles of this Issue 9/2009

Archives of Orthopaedic and Trauma Surgery 9/2009 Go to the issue