Skip to main content
Top
Literature
1.
go back to reference Tsapis M, Mignot C, Katsahian S, Arbaoui H, Ayachi A (2011) Case–control study of respiratory dynamic compliance in mechanically ventilated near-term newborns in a pre-hospital setting. Intensive Care Med 37:2008–2014PubMedCrossRef Tsapis M, Mignot C, Katsahian S, Arbaoui H, Ayachi A (2011) Case–control study of respiratory dynamic compliance in mechanically ventilated near-term newborns in a pre-hospital setting. Intensive Care Med 37:2008–2014PubMedCrossRef
2.
go back to reference Cappa P, Sciuto SA, Silvestri S (2006) Experimental evaluation of errors in the measurement of respiratory parameters of the newborn performed by a continuous flow neonatal ventilator. J Med Eng Technol 30:31–40PubMedCrossRef Cappa P, Sciuto SA, Silvestri S (2006) Experimental evaluation of errors in the measurement of respiratory parameters of the newborn performed by a continuous flow neonatal ventilator. J Med Eng Technol 30:31–40PubMedCrossRef
3.
go back to reference Lanteri CJ, Kano S, Nicolai T, Sly PD (1995) Measurement of dynamic respiratory mechanics in neonatal and paediatric intensive care: the multiple linear regression technique. Pediatr Pulmonol 19:29–45PubMedCrossRef Lanteri CJ, Kano S, Nicolai T, Sly PD (1995) Measurement of dynamic respiratory mechanics in neonatal and paediatric intensive care: the multiple linear regression technique. Pediatr Pulmonol 19:29–45PubMedCrossRef
4.
go back to reference De Luca D, Baroni S, Vento G, Piastra M, Pietrini D, Romitelli F, Capoluongo E, Romagnoli C, Conti G, Zecca E (2008) Secretory phospholipase A2 and neonatal respiratory distress: pilot study on broncho-alveolar lavage. Intensive Care Med 34:1858–1864PubMedCrossRef De Luca D, Baroni S, Vento G, Piastra M, Pietrini D, Romitelli F, Capoluongo E, Romagnoli C, Conti G, Zecca E (2008) Secretory phospholipase A2 and neonatal respiratory distress: pilot study on broncho-alveolar lavage. Intensive Care Med 34:1858–1864PubMedCrossRef
5.
go back to reference Drager (2011) BabyLog 8000 Plus operating manual. Drägerwerk, Lübeck, Germany Drager (2011) BabyLog 8000 Plus operating manual. Drägerwerk, Lübeck, Germany
6.
go back to reference Schibler A, Frey U (2002) Role of lung function testing in the management of mechanically ventilated infants. Arch Dis Child Fetal Neonatal Ed 87:F7–F10PubMedCrossRef Schibler A, Frey U (2002) Role of lung function testing in the management of mechanically ventilated infants. Arch Dis Child Fetal Neonatal Ed 87:F7–F10PubMedCrossRef
7.
go back to reference Hulskamp G, Pillow JJ, Dinger J, Stocks J (2006) Lung function tests in neonates and infants with chronic lung disease of infancy: functional residual capacity. Pediatr Pulmonol 41:1–22PubMedCrossRef Hulskamp G, Pillow JJ, Dinger J, Stocks J (2006) Lung function tests in neonates and infants with chronic lung disease of infancy: functional residual capacity. Pediatr Pulmonol 41:1–22PubMedCrossRef
Metadata
Title
Technical problems with dynamic compliance evaluation in neonates and infants
Authors
Daniele De Luca
Marco Piastra
Giorgio Conti
Publication date
01-06-2012
Publisher
Springer-Verlag
Published in
Intensive Care Medicine / Issue 6/2012
Print ISSN: 0342-4642
Electronic ISSN: 1432-1238
DOI
https://doi.org/10.1007/s00134-012-2522-3

Other articles of this Issue 6/2012

Intensive Care Medicine 6/2012 Go to the issue