Skip to main content
Top
Published in: Journal of Clinical Monitoring and Computing 3/2018

Open Access 01-06-2018 | Original Research

Technical challenges related to implementation of a formula one real time data acquisition and analysis system in a paediatric intensive care unit

Authors: B. Rajeswari Matam, Heather Duncan

Published in: Journal of Clinical Monitoring and Computing | Issue 3/2018

Login to get access

Abstract

Most existing, expert monitoring systems do not provide the real time continuous analysis of the monitored physiological data that is necessary to detect transient or combined vital sign indicators nor do they provide long term storage of the data for retrospective analyses. In this paper we examine the feasibility of implementing a long term data storage system which has the ability to incorporate real-time data analytics, the system design, report the main technical issues encountered, the solutions implemented and the statistics of the data recorded. McLaren Electronic Systems expertise used to continually monitor and analyse the data from F1 racing cars in real time was utilised to implement a similar real-time data recording platform system adapted with real time analytics to suit the requirements of the intensive care environment. We encountered many technical (hardware and software) implementation challenges. However there were many advantages of the system once it was operational. They include: (1) The ability to store the data for long periods of time enabling access to historical physiological data. (2) The ability to alter the time axis to contract or expand periods of interest. (3) The ability to store and review ECG morphology retrospectively. (4) Detailed post event (cardiac/respiratory arrest or other clinically significant deteriorations in patients) data can be reviewed clinically as opposed to trend data providing valuable clinical insight. Informed mortality and morbidity reviews can be conducted. (5) Storage of waveform data capture to use for algorithm development for adaptive early warning systems. Recording data from bed-side monitors in intensive care/wards is feasible. It is possible to set up real time data recording and long term storage systems. These systems in future can be improved with additional patient specific metrics which predict the status of a patient thus paving the way for real time predictive monitoring.
Literature
3.
go back to reference Balladini J, Rozas C, Frati E, Visente N, Orlandi C. Big data analytics in intensive care units: challenges and applicability in an Argentinian hospital. J Comput Sci Tech. 2015;15(2):61–7. Balladini J, Rozas C, Frati E, Visente N, Orlandi C. Big data analytics in intensive care units: challenges and applicability in an Argentinian hospital. J Comput Sci Tech. 2015;15(2):61–7.
5.
go back to reference De Georgia MA, Kaffashi F, Jacono FJ, Loparo KA. Information technology in critical care: Review of monitoring and data acquisition systems for patient care and research. Sci World J. 2015. doi:10.1155/2015/727694. De Georgia MA, Kaffashi F, Jacono FJ, Loparo KA. Information technology in critical care: Review of monitoring and data acquisition systems for patient care and research. Sci World J. 2015. doi:10.​1155/​2015/​727694.
11.
go back to reference Saeed M, Villarroel M, Reisner AT, Clifford G, Lehman L, Moody G, Heldt T, Kyaw TH, Moody B, Mark RG. Multiparameter intelligent monitoring in intensive care II (MIMIC II): a public access intensive care unit database. Crit Care Med. 2011;39(5):952–60.CrossRefPubMedPubMedCentral Saeed M, Villarroel M, Reisner AT, Clifford G, Lehman L, Moody G, Heldt T, Kyaw TH, Moody B, Mark RG. Multiparameter intelligent monitoring in intensive care II (MIMIC II): a public access intensive care unit database. Crit Care Med. 2011;39(5):952–60.CrossRefPubMedPubMedCentral
12.
go back to reference Parshuram CS, Duncan HP, Joffe AR, Farell CA, Lacroix JR, Middaugh KL, Hutchison JS, Wensley D, Blanchard N, Beyene J, Parkin PC. Multicentre validation of the bedside paediatric early warning system score: a severity of illness score to detect evolving critical illness in hospitalized children. Crit Care. 2011;15(R184):1–10. Parshuram CS, Duncan HP, Joffe AR, Farell CA, Lacroix JR, Middaugh KL, Hutchison JS, Wensley D, Blanchard N, Beyene J, Parkin PC. Multicentre validation of the bedside paediatric early warning system score: a severity of illness score to detect evolving critical illness in hospitalized children. Crit Care. 2011;15(R184):1–10.
13.
go back to reference Nangalia V, Prytherch DR, Smith GB. Health technology assessment review: remote monitoring of vital signs - current status and future Challenges. Crit Care. 2010;14(5):233.CrossRefPubMedPubMedCentral Nangalia V, Prytherch DR, Smith GB. Health technology assessment review: remote monitoring of vital signs - current status and future Challenges. Crit Care. 2010;14(5):233.CrossRefPubMedPubMedCentral
14.
go back to reference Kennedy CE, Turley JP. Time series analysis as input for clinical predictive modeling: Modeling cardiac arrest in a pediatric ICU. Theoret Biol Med Modell. 2011;8:40.CrossRef Kennedy CE, Turley JP. Time series analysis as input for clinical predictive modeling: Modeling cardiac arrest in a pediatric ICU. Theoret Biol Med Modell. 2011;8:40.CrossRef
15.
go back to reference Dong Y, Chbat NW, Gupta A, Hadzikadic M, Gajic O. Systems modeling and simulation applications for critical care medicine. Ann Intensive Care. 2012;2:18.CrossRefPubMedPubMedCentral Dong Y, Chbat NW, Gupta A, Hadzikadic M, Gajic O. Systems modeling and simulation applications for critical care medicine. Ann Intensive Care. 2012;2:18.CrossRefPubMedPubMedCentral
Metadata
Title
Technical challenges related to implementation of a formula one real time data acquisition and analysis system in a paediatric intensive care unit
Authors
B. Rajeswari Matam
Heather Duncan
Publication date
01-06-2018
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 3/2018
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-017-0047-6

Other articles of this Issue 3/2018

Journal of Clinical Monitoring and Computing 3/2018 Go to the issue